EN 1815-2016 en Resilient and laminate floor coverings - Assessment of static electrical propensity《弹性和复层铺地材料-人体行走电压》.pdf
《EN 1815-2016 en Resilient and laminate floor coverings - Assessment of static electrical propensity《弹性和复层铺地材料-人体行走电压》.pdf》由会员分享,可在线阅读,更多相关《EN 1815-2016 en Resilient and laminate floor coverings - Assessment of static electrical propensity《弹性和复层铺地材料-人体行走电压》.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、BS EN 1815:2016Resilient and laminate floorcoverings Assessment ofstatic electrical propensityBSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06BS EN 1815:2016 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 1815:2016. It supersede
2、s BS EN 1815:1998 which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee PRI/60, Resilient and Laminate Floor Coverings.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to incl
3、ude all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2016.Published by BSI Standards Limited 2016ISBN 978 0 580 86707 1 ICS 59.080.60; 97.150 Compliance with a British Standard cannot confer immunity from legal obligatio
4、ns.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 September 2016.Amendments/corrigenda issued since publicationDate T e x t a f f e c t e dBS EN 1815:2016EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 1815 September 2016 ICS 59.080.
5、60; 97.150 Supersedes EN 1815:1997English Version Resilient and laminate floor coverings - Assessment of static electrical propensity Revtements de sol rsilients et stratifis - valuation la propension laccumulation de charges lectrostatiques Elastische und Laminat-Bodenbelge - Beurteilung des elektr
6、ostatischen Verhaltens This European Standard was approved by CEN on 8 July 2016. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and
7、bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the re
8、sponsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav
9、Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey andUnited Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NO
10、RMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2016 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 1815:2016 EBS EN 1815:2016EN 1815:2016 (E) 2 Contents Page European fo
11、reword . 3 1 Scope 4 2 Normative References . 4 3 Terms and definitions . 4 4 Principle . 4 5 Apparatus . 4 5.1 Substructure for resilient floor coverings . 4 5.2 Substructure for laminate floor coverings . 4 5.2.1 Laminate floor coverings without attached sound absorbing material 4 5.2.2 Laminate f
12、loor coverings with attached sound absorbing material. 4 5.3 Test sandals . 5 5.4 Means of cleaning the sandals 6 5.5 lonizing source . 6 5.6 Body voltage measuring system 6 5.7 Thermometer and hygrometer 7 6 Conditioning 7 7 Test procedure . 7 7.1 Cleaning of test sandals . 7 7.2 Method A: test pro
13、cedure in laboratory conditions . 8 7.2.1 Preparation . 8 7.2.2 Discharging 8 7.2.3 Walking test 8 7.3 Method B: test procedure in situ 8 8 Calculation and expression of results 8 9 Test report 10 10 Precision 10 Annex A (informative) Precision of the method 11 BS EN 1815:2016EN 1815:2016 (E) 3 Euro
14、pean foreword This document (EN 1815:2016) has been prepared by Technical Committee CEN/TC 134 “Resilient, textile and laminate floor coverings”, the secretariat of which is held by NBN. This European Standard shall be given the status of a national standard, either by publication of an identical te
15、xt or by endorsement, at the latest by March 2017, and conflicting national standards shall be withdrawn at the latest by March 2017. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN shall not be held responsible for identifyin
16、g any or all such patent rights. This document supersedes EN 1815:1997. According to the CEN-CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denma
17、rk, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 1815:2016
18、EN 1815:2016 (E) 4 1 Scope This standard specifies a method for determining the body voltage generated when a person wearing standardized footwear walks on a resilient or laminate floor covering. The test method can be used under laboratory conditions as well as in situ. 2 Normative References The f
19、ollowing documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 61340-4-1
20、, Electrostatics - Part 4-1: Standard test methods for specific applications - Electrical resistance of floor coverings and installed floors 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 static electrical propensity tendency for charge to b
21、e generated by a person walking on the floor covering 3.2 earthed connected to a reference earth (part of the Earth considered as conductive, the electric potential of which is conventionally taken as zero) 4 Principle A floor covering is evaluated for static electrical propensity by means of a walk
22、ing test with an operator using a pair of standard sandals, walking over the floor covering situated over a earthed metal base plate (resilient floor coverings) or over a PE-foam/PE-foil situated over a grounded metal base plate (laminate floor coverings). 5 Apparatus 5.1 Substructure for resilient
23、floor coverings A earthed metal base plate shall be used, e.g. a stainless steel plate of approximately (100 200) cm and 1 mm thick. 5.2 Substructure for laminate floor coverings 5.2.1 Laminate floor coverings without attached sound absorbing material A PE foam sheet of approximately (220 120) cm an
24、d (3 0,5) mm thick, with a vertical resistance 1013 (measured at 500 V DC according to EN 61340-4-1) shall be used. This PE foam sheet is laid on a earthed metal base plate, as specified in 5.1. 5.2.2 Laminate floor coverings with attached sound absorbing material A water vapour barrier PE foil of a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN18152016ENRESILIENTANDLAMINATEFLOORCOVERINGSASSESSMENTOFSTATICELECTRICALPROPENSITY 弹性 铺地 材料 人体 行走 电压

链接地址:http://www.mydoc123.com/p-709339.html