EN 1671-1997 en Pressure Sewerage Systems Outside Buildings《建筑外压力污水系统》.pdf
《EN 1671-1997 en Pressure Sewerage Systems Outside Buildings《建筑外压力污水系统》.pdf》由会员分享,可在线阅读,更多相关《EN 1671-1997 en Pressure Sewerage Systems Outside Buildings《建筑外压力污水系统》.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、STD-BSI BS EN Lb7L-ENGL 1997 D Lb24bb9 Ob57572 720 D 3s EN BRITISH STANDARD Pressure sewerage systems outside buildings The European Standard EN 1671 : 1997 has the status of a British Standard ICs 13.060.30 .671: 1997 n-m 1111 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW -
2、 - STD.BS1 BS EN Lb7L-ENGL 1977 m 1b24bb Ob59573 bb7 W BS EN 1671 : 1997 Amd. No. This British Standard, having been prepared under the direction of the Electrotechnicai Sector Board, was published under the authority of the Standards Board and comes into effect on 15 November 1997 Date Text affecte
3、d O BSI 1997 ISBN O 680 28623 I National foreword This Briish Standard is the English language version of EN 1671 : 1997. The UK participation in its preparation was entrusted by Technid Committee WW5, Waste water engineering, to Subcommittee B/505/23, Vacuum and other special drainage systems, whic
4、h has the responsibiiity to: - aid enquirem to understand the text; - present to the responsible European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; - monitor related international and European developments and promulgate them in the U
5、K A list of organizations represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement these intemational or European pubiications may be found in the BSI Standards Catalogue under the section entitled International Standards Co
6、rrespondence Index, or by using the Find facility of the BSI Standasds Electronic Catalogue. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, the EN tite page, pages 2 to 18, a
7、n inside back cover and a back cover. STD.BSI BS EN Lb7L-ENGL 1997 = 1b2LibbS b59594 5T3 m NORME EUROPENNE EUROPAscHE NOW EN 1671 June 1997 ICs 13.060.30 Descriptors: Sanitation, water removal, sewage, pressure pipes, specifications, design, components, dimensions, performance evaluation, installati
8、on, leak tests, maintenance, quality control English version Pressure sewerage systems outside buildIngs Rseaux dassainissement sous pression lextrieur des btiments Druckentw%semngqMeme annex A gives some useful information additional to this standard, annex I3 has the figures, annex C contains the
9、bibliography and national regulations, and annex D contains AdeWons. In drafting this European Standard account has been taken of other available draft Standards. According to the CENKENELEC Internal Regulations, the nai0na.l standards organimions of the following countries are bound to implement th
10、is European Standad Austria, Belgium, Czech Republic, Denmark, Finiand, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and the United Kingdom. contents Page Foreword 2 Introduction 3 1 1.1 1.2 1.3 1.4 2 3 3.1 3.2 3.3 4 4.1 4.2
11、4.3 4.4 4.6 Scope General Limit of design Application of pressure sewerage Sources of adclitiona information Nonnative references Defnitions collecting chamber pressure generating equipment Presure sewerage system (ES) System description General Main components Collecting chamber Pressure generating
12、 equipment Pipework systems CPSS) 3 3 3 3 3 3 4 4 4 4 4 4 4 4 5 5 5 5.1 6.2 6.3 6.4 6.5 6 6.1 6.2 6.3 6.4 7 8 9 10 10.1 10.2 10.3 Requirements General Essentia requirements Performance requirements Design requirements Calculation requirements Design and calculation of pressure sewerage systems Princ
13、iples Gas formation in sumps and pipes Systems calculation Pipe sizing Installation (pipelaying) Quality control Est methods Commissioning, operation and maintenance General Statutory considerations Cleaning of the pipes Annexes A A. 1 A.2 A.3 A.4 A.6 A.6 B C c.1 c.2 c.3 D (informative) Additional i
14、nformation Application of pressure sewerage systems System description Minimum velocities Design and calculation of pressure sewerage systems Installation (pipe-laYing Operation and maintenance (informative) Figures (informative) Bibliography and national regulations National regulations Bibliograph
15、y Additional bibliography (informative) AdeWons Page 5 5 5 6 6 6 6 6 6 7 7 7 7 8 8 8 8 8 9 9 9 10 10 11 11 12 16 16 16 16 17 O BSI 1997 STD.BSI BS EN Lb7L-ENGL 1997 Lb24bb9 Ob5959b 37b W * * B Introduction This European Standard covers positive pressure sewerage systems (PSS) and has been prepared f
16、or use by the designer, manufacturem, consultants, customers and operators. A PSS is designed to transport domestic wastewaker arising from dwellings and commercial properties and shall not be used for the disposai of stonnwater or rainwater. The PSS comprises a single pressure pipe or a branched ne
17、twork of pressure pipes. The pressure generating equipment is always located at the upstream end of the pressure pipe(s). The downstream boundary of the system is defned as the point at which the total flow from the system discharges from a single pipe at atmospheric pressure into a recipient e.g. m
18、anhole, gravity sewer or sump. The use of compressed air as the only means of generating pressure is not covered in this standard This stanhd covers the control of flow to the pumping main by random operation of pumps using i.e. level control and use of logic real-time control to manage pump output.
19、 However, the annex A is mainly concerned with random operations. The use of small bore pressure pipes in conjunction with PSS may result in reduced environmental impact and consequential reduction in site construction leading to lower instalation costs. 1 scope 1.1 General This European Standard sp
20、ecifies the performance, design, operation, maintenance and insWon with related verification and test method for positive pressure driven sewerage systems outside buildings carrying wastewater. It does not provide for the evaluation of conformity of systems to this European Standard. It does not spe
21、c - the pressure generating equipment (4.4); - compressed air unit, if required (4.4.2); - pipework (4.6); - pipejoints (4.6.2); - pump unit (4.4.1); - (4.6.3). figure B.l shows an example of a pressure sewerage system. 4.3 Collecting chamber The collecting chamber may serve one or more buildings. T
22、he maximum number of buildings Will be dictated by the capacity of the pressure generating equipment. Liability arising from the operation and maintenance of the collecting chamber, or local regulations, may dictate the use of separate collecting chambers for each dwelling or building. The essential
23、 elements of a collecting chamber are: - ventilation; - a suitably rated electrical supply; - controls and alarm equipment; - level control sensors within the chamber for automatic control of the pumps; - non-return valves and isolation valves to prevent back flow from the downstream system. Constsu
24、ction materials shall be suitable for operation with sewage. The working volume in the sump and the residual volume remaining at the end of the pumping sequence shall be designed to be as small as possible without adversely effecting the operation of the pump. (See also 4.2.) When designing and inst
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN16711997ENPRESSURESEWERAGESYSTEMSOUTSIDEBUILDINGS 建筑 压力 污水 系统 PDF

链接地址:http://www.mydoc123.com/p-709192.html