EN 161-2011 en Automatic shut-off valves for gas burners and gas appliances (Incorporates Amendment A3 2013)《自动切断阀气体燃烧器和燃气用具》.pdf
《EN 161-2011 en Automatic shut-off valves for gas burners and gas appliances (Incorporates Amendment A3 2013)《自动切断阀气体燃烧器和燃气用具》.pdf》由会员分享,可在线阅读,更多相关《EN 161-2011 en Automatic shut-off valves for gas burners and gas appliances (Incorporates Amendment A3 2013)《自动切断阀气体燃烧器和燃气用具》.pdf(62页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 161:2011Automatic shut-off valves forgas burners and gas appliancesBS EN 161:2011+A3:2013BS EN 161:2011+A3:2013National forewordThis British Standard is the UK implementati
2、on of EN 161:2011+A3:2013. It supersedes BS EN 161:2011+A2:2012, which is withdrawn.The start and finish of text introduced or altered by amendment is indicated in the text by tags. Tags indicating changes to CEN text carry the number of the CEN amendment. For example, text altered by CEN amendment
3、A2 is indicated by #$.Please note that CEN did not issue an amendment A1 to this document. The UK participation in its preparation was entrusted to Technical Committee GSE/22, Safety and control devices for gas and oil burners and gas burning appliances.A list of organizations represented on this co
4、mmittee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2013. Published by BSI Standards Limited 2013ISBN 978 0 580 81979 7 ICS 23
5、.060.40Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 May 2011. Amendments/corrigenda issued since publicationDate Text affected31 October 2012 Implementatio
6、n of CEN amendment A2:201231 May 2013 Implementation of CEN amendment A3:2013BRITISH STANDARDEUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 161:2011+A3 January 2013 ICS 23.060.10 Supersedes EN 161:2011+A2:2012English Version Automatic shut-off valves for gas burners and gas appliances Robinets
7、 automatiques de sectionnement pour brleurs gaz et appareils gaz Automatische Absperrventile fr Gasbrenner und Gasgerte This European Standard was approved by CEN on 20 February 2011 and includes Amendment 2 approved by CEN on 10 June 2012 and Amendment 3 approved by CEN on 10 November 2012. CEN mem
8、bers are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on applicat
9、ion to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Manage
10、ment Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
11、 Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 B
12、russels 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 161:2011+A3:2013: EEN 161:2011+A3:2013 (E) 2 Contents Page Foreword 4 1 Scope 6 2 Normative references 6 3 Terms and definitions .7 4 Classification 8 5 Units of measurem
13、ent and test conditions .9 6 Construction requirements .9 7 Performance 14 8 EMC/Electrical requirements . 22 9 Marking, installation and operating instructions 24 Annex A (informative) Gas connections in common use in the various countries . 26 Annex B (informative) Leak-tightness test volumetric m
14、ethod 27 Annex C (informative) Leak-tightness test pressure loss method . 28 Annex D (normative) Conversion of pressure loss into leakage rate . 29 Annex E (normative) Electrical/electronic component fault modes . 30 Annex F (normative) Additional requirements for safety accessories and pressure acc
15、essories as defined in EU Directive 97/23/EC . 31 Annex G (normative) Materials for pressurized parts 32 Annex H (informative) Additional materials for pressurized parts 33 Annex I (normative) Requirements for controls used in DC supplied gas burners and gas burning appliances . 34 Annex AA (normati
16、ve) %Method for the determination of Performance Level (PL) b) normative references: ISO 4400 and ISO 6952 are changed to EN 175301-803; c) terms and definitions are aligned to #EN 13611:2007+A2:2011$; d) %sub-clause 6.2.105, Balanced valves, has been changed; e) sub-clause 6.2.107, Additional requi
17、rements for shut-off function, has been changed; g) %sub-clause 7.105.1, Sealing force requirements, has been changed; BS EN 161:2011+A3:2013EN 161:2011+A3:2013 (E) 5 i) %addition of new Annexes AA and BB; b) leak tightness; c) sealing force (ability to withstand backpressure, to be checked by testi
18、ng or calculation); d) closing force friction force; e) closing time including the influence to the Burner Control (EN 298); f) no uncontrolled opening of the automatic shut-off valve. As a result of this failure mode analysis, additional constructional requirements shall be fulfilled and/or additio
19、nal faults compared to #EN 13611:2007+A2:2011$, Annex E shall be included into the fault assessment. The outcome of the analysis shall provide a set of conditions under which the new design can be used in an automatic shut-off valve. These conditions involve construction requirements, safety require
20、ments, performance requirements and test methods. The fault reaction time shall be declared by the manufacturer. Failure of mechanical parts adversely affecting the performance requirements of this European Standard is considered as an abnormal situation and can therefore be considered as a first fa
21、ult according to the test method in #EN 13611:2007+A2:2011$, 6.6. BS EN 161:2011+A3:2013EN 161:2011+A3:2013 (E) 12 However, if mechanical parts are designed according to the constructional requirements of Clause 6 of this European Standard, failure of these parts is not considered. # 6.2.107 Additio
22、nal requirements for shut-off function 6.2.107.1 Diaphragms that assist the shut-off function Shut-off functions using a diaphragm to apply (part of) the closing force to the closure member shall be designed in such a way that, when the diaphragm is damaged, the closure member closes and the maximum
23、 internal leakage rate of the valve is limited to 1 dm/h. Conformity shall be verified by the method given in 6.2.107.2. 6.2.107.2 Leakage test Remove or rupture the part(s) assisting the shut-off function. De-energize the valve. Measure the internal leakage rate of the valve according to 7.3.$ 6.3
24、Materials 6.3.1 General material requirements Shall be according to #EN 13611:2007+A2:2011$, 6.3.1. 6.3.2 Housing Shall be according to #EN 13611:2007+A2:2011$, 6.3.2. 6.3.3 Test for leakage of housing after removal of non-metallic parts Shall be according to #EN 13611:2007+A2:2011$, 6.3.3. 6.3.4 Zi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN1612011ENAUTOMATICSHUTOFFVALVESFORGASBURNERSANDGASAPPLIANCESINCORPORATESAMENDMENTA32013 自动 切断 气体 燃烧

链接地址:http://www.mydoc123.com/p-709131.html