1、BRITISH STANDARDBS EN 14175-4:2004 Fume cupboards Part 4: On-site test methodsICS 71.040.10; 91.140.30nullnull nullnullnullnullnullnullnull nullnullnullnullnullnullnull nullnullnull nullnullnullnullnullnullnullnullnullnull nullnullnullnullnullnull nullnull nullnullnullnullnullnullnullnullnull nullnu
2、ll nullnullnullnullnullnullnullnullnull nullnullnullIncorporating corrigendum January 2014National forewordThis British Standard is the UK implementation of EN 14175-4:2004. Together with BS EN 14175-1:2003, BS EN 14175-2:2003, BS EN 14175-3:2003, DD CEN/TS 14175-5:2006 and BS EN 14175-6:2006, BS EN
3、 14175-7:2012, it supersedes BS 7258-1:1994, BS 7258-2:1994, BS 7258-3:1994 and BS 7258-4:1994 which are withdrawn.The UK committee advises that prior to purchasing a fume cupboard, a risk assessment should be performed to assess the risks associated with the substances that are to be manipulated. T
4、his would ensure that the fume cupboard is suitable for its intended purpose and that current exposure limits for toxic substances are not exceeded. It is suggested, therefore, that users may need to draw up a specification appropriate to their particular requirements, within the overall permissible
5、 limits of this standard and the information on installation included in the National Annex. For users with little experience of purchasing fume cupboards, it may be helpful for trade associations, employers bodies or other organizations associated with a particular activity to give guidance on a su
6、itable specification. An example would be Building Bulletin 88 from the Architects b) the type designation including the year of production; c) the date of commissioning testing and the reference to the type test report; d) the general room air conditions during air flow tests, including temperature
7、, barometric pressure, air humidity and pressure difference between room and the adjacent space as well as make-up air and room extract air;e) the status of fume cupboards and other extract devices in the room and the specific position of the tested fumecupboard; f) the results of the inspections (s
8、ee 5.2); EN 14175-4:200414 g) the results of the tests perf ormed during the commissioning testing in accordancewith the test resultrequirements specified for each test (see 5.4 to 5.11);h) a reference to this document EN 14175-4 and the testmethod(s) from this document which has/have beenperformed.
9、 Those test results intended to serve as reference values for subsequent routine testing should be documented inan additional table under the header “Reference values for routine testing“. 9.2Test report for routine testing of type tested fume cupboards (see Clause 6)The routine test report shall in
10、clude the fol lowing items as a minimum:a) individual identification number of the fume cupboard and date of test; b) the reference to the type test report, t he commissioning test report and the last routine test report, if available;c) the general room air conditions during air flow tests, includi
11、ng temperature, barometric pressure, air humidity and pressure difference between room and the adjacent space as well as make-up air and room extract air;d) the status of fume cupboards and other extract devices in the room and the specific position of the tested fumecupboard; e) the results of the
12、inspections (see 6.7); f) the results of the tests performed during the routine testing in acc ordancewith the test result requirementsspecified for each test (see 6.2 to 6.6); g) a reference to this document EN 14175-4 and the testmethod(s) from this document which has/have beenperformed. 9.3Test r
13、eport for qualification testing of non type tested fume cupboards (see Clause 7)According to 9.1 as far as applicable. 9.4Test report for routine testing of qualified fume cupboards (see Clause 8)The routine test report shall include the following itemsas a minimum:a) individual identification numbe
14、r of the fume cupboard and date of test; b) the date of qualification testing, the reference to the qualification test report and the last routine test report, ifavailable;c) the general room air conditions during air flow tests, including temperature, barometric pressure, air humidity and pressure
15、difference between room and the adjacent space as well as make-up air and room extract air;d) the status of fume cupboards and other extract devices in the room and the specific position of the tested fumecupboard; e) the results of the inspections (see 6.7); f) the results of the tests performed du
16、ring the routine testing in accordancewith the test result requirementsspecified for each test (see Clause 6); g) a reference to this document EN 14175-4 and the testmethod(s) from this document which has/have beenperformed. EN 14175-4:2004BS EN 14175-4:2004 BSI 2007 15National annex NA (informative
17、)Recommendations for the exchange of information and recommendations for installationNA.1 IntroductionThe requirements contained in the BS EN 14175 series of standards for laboratory fume cupboards supersede the BS 7258 series of standards and these are now withdrawn. However, to ensure completeness
18、 of the requirements in the British implementation of these European standards, the safeguards containedin the BS 7258 series (i.e. recommendations for the exchange of information, installation,selection, use and maintenance) are retained. This informative national annex reproduces clauses 2.1 , 2.2
19、 , 2.3, 2.4, 3.2and 3.3 of BS 7258-2:1994, plus clauses 4.2 and 5 of BS 7258-3:1994.NA.2 Exchange of informationNOTE Clause NA.2 reproduces clauses 2.1, 2.2, 2.3, 2.4 , 3.2 and 3.3 of BS 7258-2:1994.NA.2.1 GeneralIt is strongly recommended that, for laboratory fume cupboards, the information given i
20、nclauses NA.2.2to NA.2.4 of this national annex shouldbe exchanged by the purchaser and the vendor/installer.NA.2.2 Information to be obtained from the purchaser by the vendor/installerNOTE For the purposes of this BritishStandard, it is assumed in this clause that the vendor is the same party as th
21、e installer. Ifthis is not the case both parties should obtain the information listed in items a) to g) but it is necessary only for the installer to obtain the information listed in items h) to n).The following information should be obtainedfrom thepurchaser by the vendor/installer:a) the materialo
22、fconstruction for any part ofthe fume cupboardthat will be affected byfumes emanating from the processes for which thefume cupboard will be used;b) any specific requirements such as minimum flow rate;c) the minimum dimensions of the work surface;d) the normal sash working height, the maintenance sas
23、h height, and the width of the opening in the plane of the sash;e) the services to be fitted;f) the maximum external dimensions of the fume cupboard, and its dismantledcomponents if appropriate, and the dimensions available for access into the building and internal access to where the fume cupboard
24、is to be installed;g) whether the fume cupboard is to be used for manipulation of highly flammable liquids or other particularly hazardous substances;h)the following details of the siting of the fume cupboard:1)general details of the buildingin which the fume cupboard is to be installed,the location
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN1417542004ENFUMECUPBOARDSPART4ONSITETESTMETHODS 通风 部分 现场 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-708768.html