EN 13757-5-2015 en Communication systems for meters - Part 5 Wireless M-Bus relaying《仪表通信系统 第5部分 无线计量总线中继》.pdf
《EN 13757-5-2015 en Communication systems for meters - Part 5 Wireless M-Bus relaying《仪表通信系统 第5部分 无线计量总线中继》.pdf》由会员分享,可在线阅读,更多相关《EN 13757-5-2015 en Communication systems for meters - Part 5 Wireless M-Bus relaying《仪表通信系统 第5部分 无线计量总线中继》.pdf(112页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationBS EN 13757-5:2015Communication systems for metersPart 5: Wireless M-Bus relayingBS EN 13757-5:2015 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 13757-5:2015. It supersedes BS EN 13757-5:2008 which is withdrawn.The UK participation in
2、 its preparation was entrusted to Technical Committee PEL/894, Remote Meter Reading.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its
3、 correct application. The British Standards Institution 2015. Published by BSI Standards Limited 2015ISBN 978 0 580 84088 3 ICS 33.200; 35.100.10; 35.100.20 Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the
4、 Standards Policy and Strategy Committee on 30 November 2015.Amendments/corrigenda issued since publicationDate T e x t a f f e c t e dBS EN 13757-5:2015EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 13757-5 November 2015 ICS 33.200; 35.100.10; 35.100.20 Supersedes EN 13757-5:2008 English Vers
5、ion Communication systems for meters - Part 5: Wireless M-Bus relaying Systmes de communication - Partie 5: Relais de transmission sans fil M-Bus Kommunikationssysteme fr Zhler - Teil 5: Weitervermittlung This European Standard was approved by CEN on 22 August 2015. CEN members are bound to comply w
6、ith the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Man
7、agement Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same s
8、tatus as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Ma
9、lta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 C
10、EN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13757-5:2015 E BS EN 13757-5:2015EN 13757-5:2015 (E) 2 Contents Page European foreword . 5 1 Scope 6 2 Normative references 6 3 Terms and definitions . 6 4 Symbols . 9 5 Introduction 9
11、 5.1 General 9 5.2 Use of retransmission 9 5.3 Repeating 10 5.4 Relaying . 12 5.4.1 Overview . 12 5.4.2 Use of routers 15 5.4.3 Use of gateways . 15 5.4.4 Data duplication . 16 5.4.5 Use of power strobed units . 17 5.4.6 Error handling . 18 5.4.7 Time synchronization . 18 5.5 Protocol possibilities
12、20 6 Mode P, protocol using routers . 20 6.1 General . 20 6.2 Physical Layer protocol 20 6.2.1 General . 20 6.2.2 Transmitter 21 6.2.3 Receiver . 22 6.3 Data encoding 23 6.3.1 Manchester encoding 23 6.3.2 Order of transmission of the encoded data 23 6.3.3 Wake up and preamble chip sequences . 23 6.4
13、 Data Link Layer protocol . 23 6.4.1 General . 23 6.4.2 Frame format . 23 6.4.3 C-field 25 6.4.4 M- and A-fields . 26 6.4.5 The CI-field . 26 6.4.6 Message handling . 26 6.4.7 Timing requirements 27 6.5 Network Layer protocol . 28 6.5.1 General . 28 6.5.2 Network Layer format 28 6.5.3 Relaying rules
14、 29 6.6 Application Layer protocol . 30 6.6.1 CI-field 30 6.6.2 Error reporting service 30 6.6.3 Network management service . 32 BS EN 13757-5:2015EN 13757-5:2015 (E) 3 7 Mode R2, protocol using gateways . 38 7.1 General . 38 8 Mode Q, protocol supporting precision timing 38 8.1 General . 38 8.2 Phy
15、sical Layer protocol 38 8.2.1 General . 38 8.2.2 Transmitter . 38 8.2.3 Receiver 39 8.3 Data Encoding 40 8.3.1 NRZ encoding . 40 8.3.2 Order of transmission of the encoded data . 40 8.3.3 Wake up and preamble bit sequences 41 8.4 Data Link Layer protocol . 41 8.4.1 General . 41 8.4.2 Frame format .
16、41 8.4.3 Normal Data Link Layer frame handling 44 8.4.4 Search Link Layer frame handling 45 8.5 Mode Q, Network Layer protocol 47 8.5.1 General . 47 8.5.2 Network layer format 47 8.5.3 Address conversion rules 50 8.5.4 Routing rules 50 8.5.5 Timing requirements 53 8.6 Mode Q, Application Layer proto
17、col 54 8.6.1 General . 54 8.6.2 EN 13757-1 Application Layer . 54 8.6.3 Error reporting 55 8.6.4 Alarm reporting 57 8.6.5 Network Management service . 58 8.6.6 Timing requirements 62 8.6.7 COSEM extension. 63 9 Single-hop repeaters . 64 9.1 General . 64 9.1.1 Ways of operating . 64 9.1.2 Unregistere
18、d repetition . 64 9.1.3 Registered repetition 65 9.1.4 Assigned repetition 65 9.2 Physical Layer protocol and data encoding 65 9.3 Media Access duty cycle . 66 9.4 Timing . 66 9.4.1 General . 66 9.4.2 Uplink delay default time slot . 66 9.4.3 Uplink delay optional timeslot . 67 9.4.4 Uplink delay -
19、randomly delayed repetition . 67 9.4.5 Downlink delay and FAC-Transmission delay 67 9.4.6 Installation announcement delay . 68 9.4.7 Other Device response delay 68 9.5 Data Link Layer protocol . 68 9.5.1 General . 68 9.5.2 C-Field . 68 9.5.3 Address . 69 9.6 Transport Layer and Extended Link Layer p
20、rotocol 69 BS EN 13757-5:2015EN 13757-5:2015 (E) 4 9.6.1 General . 69 9.6.2 Hop Count, (H-field) 69 9.6.3 Repeated Access (R-field) . 70 9.6.4 Transfer of H- and R-fields within a frame . 70 9.7 Application Layer Protocol . 71 9.7.1 General . 71 9.7.2 Common functions . 71 9.7.3 CI field . 72 9.7.4
21、Repeater management data elements 72 9.8 Error Reporting Services . 75 9.8.1 General . 75 9.8.2 Error type 75 9.9 Management Functions 76 9.9.1 General . 76 9.9.2 Data elements 76 9.9.3 Meter Management 78 9.9.4 Get List 81 9.9.5 Radio Scan List 84 9.9.6 Repeater Status . 86 Annex A (informative) Ti
22、ming Diagrams for a Single Hop Repeater 89 Annex B (informative) Message examples . 100 B.1 Command to Repeater and response 100 B.1.1 General . 100 B.1.2 Configuration . 100 B.1.3 Detailed data, command 101 B.1.4 Detailed data, acknowledge . 102 B.2 Readout of Radio Scan List 102 B.2.1 General . 10
23、2 B.2.2 Configuration . 102 B.2.3 Detailed data, command 103 B.2.4 Detailed data, acknowledge . 104 B.2.5 Detailed data, request 105 B.2.6 Detailed data, response . 106 Bibliography . 108 BS EN 13757-5:2015EN 13757-5:2015 (E) 5 European foreword This document (EN 13757-5:2015) has been prepared by T
24、echnical Committee CEN/TC 294 “Communication systems for meters”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by May 2016, and conflicting national standa
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN1375752015ENCOMMUNICATIONSYSTEMSFORMETERSPART5WIRELESSMBUSRELAYING 仪表 通信 系统 部分 无线 计量 总线 中继 PDF

链接地址:http://www.mydoc123.com/p-708250.html