EN 12976-2-2017 en Thermal solar systems and components - Factory made systems - Part 2 Test methods《太阳供热系统和部件-工厂制造系统-第1部分 试验方法》.pdf
《EN 12976-2-2017 en Thermal solar systems and components - Factory made systems - Part 2 Test methods《太阳供热系统和部件-工厂制造系统-第1部分 试验方法》.pdf》由会员分享,可在线阅读,更多相关《EN 12976-2-2017 en Thermal solar systems and components - Factory made systems - Part 2 Test methods《太阳供热系统和部件-工厂制造系统-第1部分 试验方法》.pdf(80页珍藏版)》请在麦多课文档分享上搜索。
1、BS EN 12976-2:2017Thermal solar systems andcomponents Factory madesystemsPart 2: Test methodsBSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06BS EN 12976-2:2017 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 12976-2:2017. It supe
2、rsedes BS EN 12976-2:2006 which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee RHE/25, Solar Heating.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the neces
3、sary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2017.Published by BSI Standards Limited 2017ISBN 978 0 580 86105 5 ICS 27.160 Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was
4、 published under the authority of the Standards Policy and Strategy Committee on 31 January 2017.Amendments/corrigenda issued since publicationDate T e x t a f f e c t e dBS EN 12976-2:2017EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 12976-2 January 2017 ICS 27.160 Supersedes EN 12976-2:2006
5、English Version Thermal solar systems and components - Factory made systems - Part 2: Test methods Installations solaires thermiques et leurs composants -Installations prfabriques en usine - Partie 2 : Mthodes dessai Thermische Solaranlagen und ihre Bauteile - Vorgefertigte Anlagen - Teil 2: Prfverf
6、ahren This European Standard was approved by CEN on 15 April 2016. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical
7、 references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of
8、 a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Mac
9、edonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALIS
10、ATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2017 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 12976-2:2017 EBS EN 12976-2:2017EN 12976-2:2017 (E) 2 Contents Page European
11、 foreword . 6 Introduction 8 1 Scope . 10 2 Normative references . 10 3 Terms and definitions 10 4 Symbols and abbreviations 10 5 Testing 11 5.1 Freeze resistance 11 5.1.1 General . 11 5.1.2 Systems using antifreeze fluid . 11 5.1.3 Drain-back systems . 11 5.1.4 Drain-down systems . 12 5.1.5 Freeze
12、protection and combined control functions 12 5.1.6 Other systems 12 5.2 Over temperature protection 13 5.2.1 Purpose 13 5.2.2 Apparatus 13 5.2.3 Procedure 13 5.2.4 Reporting requirements 14 5.3 Pressure resistance . 14 5.3.1 Purpose 14 5.3.2 Apparatus 14 5.3.3 Safety precaution . 15 5.3.4 Procedure
13、15 5.3.5 Reporting requirements 16 5.4 Water contamination 16 5.5 Testing the resistance against mechanical load . 17 5.5.1 Purpose 17 5.5.2 Apparatus 17 5.5.3 Safety precaution . 17 5.5.4 Calculation procedure for the mechanical load 18 5.5.5 Procedure 20 5.5.6 Reporting requirements 20 5.6 Lightni
14、ng protection . 21 5.7 Safety equipment 21 5.7.1 Safety valves . 21 5.7.2 Safety lines and expansion lines . 22 5.7.3 Blow-off lines . 22 5.8 Labelling 22 5.9 Thermal performance characterization 22 5.9.1 Introduction . 22 5.9.2 Test procedure 23 5.9.3 Prediction of yearly performance indicators . 2
15、4 5.10 Ability of solar-plus-supplementary systems to cover the load 31 BS EN 12976-2:2017EN 12976-2:2017 (E) 3 5.10.1 General . 31 5.10.2 Boundary conditions for auxiliary heating . 31 5.10.3 Boundary conditions for daily load 32 5.10.4 Determination of the ability to cover the maximum daily load b
16、y means of testing the system 33 5.10.5 Determination of the ability to cover the maximum daily load by means of numerical simulations 33 5.10.6 Determination of the ability to cover the daily load defined by the European load profiles by means of numerical simulations . 33 5.10.7 Requirements for m
17、ixed water at 40 C . 34 5.11 Reverse flow protection . 36 5.12 Electrical safety . 36 Annex A (normative) Thermal performance presentation sheet 37 Annex B (normative) Reference conditions for performance prediction . 39 B.1 General . 39 B.2 Pipe diameter and insulation thickness . 42 B.3 Calculatio
18、n of cold water temperature at reference location 43 B.4 Additional set of reference conditions for annual performance calculations 44 B.5 Reference conditions for the performance of the auxiliary heater 47 Annex C (informative) Assessment of the ability of solar DHW systems to resist the extreme cl
19、imatic conditions . 48 C.1 Indoor and outdoor test procedure for assessment of the frost resistance of solar DWH systems with outdoor storage tank or system using heat transfer fluid with the risk of freezing . 48 C.1.1 Objective and applicability 48 C.1.2 Apparatus and mounting of the system 48 C.1
20、.3 Test procedure 49 C.1.4 Test conditions Determination of the test conditions for freezing period . 50 C.1.5 Results 50 C.2 Indoor test procedure for assessment of the reliability of solar DWH systems in respect of overheating protection 51 C.2.1 Objective and applicability 51 C.2.2 Apparatus and
21、mounting of the system 51 C.2.3 Test procedure 53 C.2.4 Test conditions 53 C.2.5 Results 55 Annex D (informative) Ageing test for thermostatic valves . 57 D.1 General . 57 D.2 Test arrangement . 57 D.3 Test Procedure 58 D.4 Results 59 Annex E (informative) Lightning protection test for solar heating
22、 systems 60 E.1 Field of application. 60 E.2 Purpose 60 E.3 Requirements . 60 E.4 Apparatus 61 E.5 Test procedure 61 E.5.1 Test conditions 61 E.5.2 Solar heating system installation 61 E.5.3 Separation distance St. 61 BS EN 12976-2:2017EN 12976-2:2017 (E) 4 E.5.4 Size of the bonding cable or strip .
23、 61 E.5.5 Bridging between tank and supports . 61 E.5.6 Bridging between collectors and supports . 62 E.5.7 Bridging between collectors and tank 62 E.5.8 Connecting terminal with Lightning Protection System (LPS) 62 E.5.9 Metal sheets covering parts of the solar heating system . 62 E.5.10 Heating ef
24、fects due to lightning currents 62 E.5.11 Mechanical durability due to lightning mechanical loads . 62 E.6 Report . 62 E.7 Conclusions. 62 Annex F (informative) Lightning Protection testing sheet . 63 Annex G (normative) Reporting format in the framework of the EU Regulations CDR 811, 812 and 814 da
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN1297622017ENTHERMALSOLARSYSTEMSANDCOMPONENTSFACTORYMADESYSTEMSPART2TESTMETHODS 太阳 供热 系统 部件 工厂 制造 部分

链接地址:http://www.mydoc123.com/p-707041.html