1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 12812:2008Falsework Performance requirements and general designBS EN 12812:2008 BRITISH STANDARDA list of organizations represented on this committee can beobtained on requ
2、est to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. BSI 2011 ISBN 978 0 580 60505 5 ICS 91.220 Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Stand
3、ard was published under the authority of theStandards Policy and Strategy Committee on 31 January 2011.Amendments issued since publicationDateT e x t a f f e c t e dNational forewordThis British Standard is the UK implementation of EN 12812:2008. It supersedes BS EN 12812:2004 which is withdrawn.The
4、 UK participation in its preparation was entrusted to TechnicalCommittee B/514, Access and support equipment.The design methodology within BS EN 12812:2008 is significantly different from that in BS 5975. Technical Committee B/514 advises that caution should be taken when applying BS EN 12812:2008.B
5、S EN 12812:2008 specifies performance requirements for the design of falsework in accordance with one of three classes: A, B1 and B2. Limit state design methods are specified for design Classes B1 and B2. It does not provide guidance for the structural design of Class A. BS 5975, which exists in par
6、allel with this standard and provides recommendations on the design of falsework, without definition of classes or physical parameters and using permissible stress methods, is recommended by Technical Committee B/514 as a suitable method for the structural design of Class A falsework, as defined in
7、BS EN 12812:2008.The Bragg Report, published in 1975 by the Advisory Committee on Falsework, first introduced a minimum lateral stability force. This force was subsequently incorporated, as a minimum horizontal disturbing force of 2.5 % of the applied vertical load in BS 5975, assuming first-this fo
8、rce has made a significant contribution to the safe use of falsework in the UK since its introduction. Technical Committee B/514 also advises that BS EN 12812:2008 does not recommend a minimum horizontal force.BS EN 12812:2008 does not provide guidance on procedures necessary for the successful mana
9、gement of work on site. The recommendations of the Bragg Report in respect of the falsework coordinator have not been included in it. BS 5975 includes procedural controls for all temporary works, including falsework, for the design, independent checking of the design, and for the successful manageme
10、nt of work on site, including the appointment of a temporary works coordinator. Technical Committee B/514 reaffirms the importance of these controls.This standard contains a National Annex NA that provides informative guidance on its application. It should be noted that there are a number of textual
11、 and numerical differences between the 2004 and 2008 editions; only those that are considered to be material are commented on in the National Annex NA. It is therefore not a comprehensive listing of all of the differences. Further, the UK committee advises that the symbols used in this standard shou
12、ld be read with caution.order analysis. Technical Committee B/514 advises that the application of EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 12812July 2008ICS 91.220 Supersedes EN 12812:2004 English VersionFalsework - Performance requirements and general designEtaiements - Exigences de perfor
13、mance et mthodes deconception et calculsTraggerste - Anforderungen, Bemessung und EntwurfThis European Standard was approved by CEN on 7 June 2008.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a
14、 national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version
15、in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark,
16、Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROP
17、ISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2008 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 12812:2008: EEN 12812:2008 (E) 2 Contents Page Foreword. 3 Introduction 4 1 Scope . 5 2 Normative re
18、ferences . 5 3 Terms and definitions. 6 4 Design classes 7 4.1 General. 7 4.2 Design class A 7 4.3 Design class B 7 5 Materials 8 5.1 General. 8 5.2 Basic requirements for materials 8 5.3 Weldability . 8 6 Brief 8 7 Design requirements 8 7.1 General. 8 7.2 Thickness of material . 9 7.3 Connections 9
19、 7.4 Flexibility of prefabricated support towers 9 7.5 Foundation 10 7.6 Towers providing support . 12 8 Actions. 13 8.1 General. 13 8.2 Direct actions 13 8.3 Indirect actions . 17 8.4 Other actions “Q9” 17 8.5 Load combinations. 17 9 Structural design for classes B1 and B2 18 9.1 Technical document
20、ation 18 9.2 Structural design 20 9.3 Imperfections and boundary conditions 23 9.4 Calculation of internal forces 30 9.5 Characteristic values of resistance and friction values . 37 Annex A (informative) Relation with site activities . 40 Annex B (informative) . 41 Bibliography . 42 BS EN 12812:2008
21、EN 12812:2008 (E) 3 Foreword This document (EN 12812:2008) has been prepared by Technical Committee CEN/TC 53 “Temporary works equipment”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or b
22、y endorsement, at the latest by January 2009, and conflicting national standards shall be withdrawn at the latest by January 2009. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible fo
23、r identifying any or all such patent rights. This document supersedes EN 12812:2004. This European Standard is one of a package of standards that includes also EN 12810-1, EN 12810-2, EN 12811-1, EN 12811-2, EN 12811-3, EN 12813. According to the CEN/CENELEC Internal Regulations, the national standa
24、rds organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Por
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN128122008ENFALSEWORKPERFORMANCEREQUIREMENTSANDGENERALDESIGN 脚手架 性能 要求 一般 设计 PDF

链接地址:http://www.mydoc123.com/p-706822.html