EN 12152-2002 en Curtin Walling - Air Permeability - Performance Requirements and Classification《幕墙 透气率 性能要求和分类》.pdf
《EN 12152-2002 en Curtin Walling - Air Permeability - Performance Requirements and Classification《幕墙 透气率 性能要求和分类》.pdf》由会员分享,可在线阅读,更多相关《EN 12152-2002 en Curtin Walling - Air Permeability - Performance Requirements and Classification《幕墙 透气率 性能要求和分类》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、Curtain walling Air permeability Performance requirements and c1assii:ication The European Standard EN 12152:2002 has the status ofa British Standard ICs 91.060.10 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW BS EN 12152:2002 BS EN 12152:2002 Amd. No. National foreword Date
2、 Comments This British Standard, having been prepared under the direction of the Building and Civil Engineering Sector Policy and Strategy Committee, was published under the authority of the Standards Policy and Strategy Committee on 26 March 2002 This British Standard is the official English langua
3、ge version of EN 12152:2002. The UKparticipation in its preparation was entrusted by Technical Committee B/53 8, Doors, windows, shutters, hardware and curtain walling, to Subcommittee B/538/6, Curtain walling, which has the responsibility to: - - aid enquirers to understand the text; present to the
4、 responsible European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. - A list of organizations represented on this subcommittee can be obtained on reque
5、st to its secretary. Cr oss-r e fer enc e s The British Standards which implement international or European publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Find” facility
6、 of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligation
7、s. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 10, an inside back cover and a back cover. The BSI copyright date displayed in this document indicates when the document was last issued. O BSI 26 March 2002 ISBN O 580 39416 6 EUROPEAN ST
8、ANDARD NORME EUROPENNE EUROPISCHE NORM EN 12152 February 2002 ICs 91.060.10 English version Curtain walling - Air permeability - Petformance requirements and classification Faades rideaux - Permabilit lair - Exigences de performance et classification Vorhangfassaden - Luftdurchlssigkeit - Leistungsa
9、nforderungen und Klassifizierung This European Standard was approved by CEN on 9 November 2001 CEN members are bound to comply with the CENKENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-dat
10、e lists and bibliographical references concerning such national standards may be obtained on application to the Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the re
11、sponsibility of a CEN member into its own language and notified to the Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Ma
12、lta, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION EUROPISCHES KOMITEE FR NORMUNG COMIT EUROPEN DE NORMALISATION Management Centre: rue de Stassart, 36 B-1050 Brussels O 2002 CEN All rights of exploitation in any form and by any
13、means reserved worldwide for CEN national Members. Ref. No. EN 12152:2002 E EN 12152:2002 (E) Contents Foreword . . 3 1 Scope 4 2 Normative references . 4 3 Terms and definitions . 4 4 Requirements . 5 5 Test method . 6 6 Class if icatio n . 6 . 10 Bib I i og ra p h y . 2 EN 12152:2002 (E) Foreword
14、This document EN 12152:2002 has been prepared by Technical Committee CEN/TC 33 “Doors, windows, shutters, building hardware and curtain walling”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical
15、text or by endorsement, at the latest by August 2002, and conflicting national standards shall be withdrawn at the latest by August 2002. This European Standard is part of a series of European Standards dedicated to curtain walling products and derives from performance requirements. This European St
16、andard forms part of a series of curtain walling standards as specified in the Product Standard prEN 13830. According to the CENICENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Czech Republ
17、ic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and the United Kingdom. 3 EN 12152:2002 (E) 1 Scope This European Standard specifies requirements and classification of air permeability of both fixed
18、and openable parts of curtain walling, under positive and negative static air pressure. NOTE This European Standard applies to curtain walling as specified in prEN 13830. 2 Normative references This European Standard incorporates by dated or undated reference, provisions from other publications. The
19、se normative references are cited at the appropriate places in the text, and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision. For unda
20、ted references the latest edition of the publication referred to applies (including amendments). EN 121 53, Curtain walling -Air permeability - Test method. EN 12207, Windows and doors -Air permeability - Classification. prEN 131 19, Curtain walling - Terminology. prEN 13830, Curtain walling - Produ
21、ct Standard. ENV 1991 -2-4, Eurocode I: Basis of design and actions on structures - Part 2-4: Actions on structures - Wind action. 3 Terms and definitions For the purposes of this European Standard, the terms and definitions given in prEN 13119 together with the following apply: 3.1 test pressure di
22、fferential air pressure between the two faces of the test specimen, expressed in Pascals (Pa) 3.2 positive pressure when the outer face is subjected to higher air pressure than the inner face 3.3 negative pressure when the outer face is subjected to lower air pressure than the inner face 3.4 air per
23、meability passage of air through the curtain walling when subjected to positive or negative air pressure The volume being expressed as a rate in cubic metres per hour (m3/h), this rate being related to the overall area of the curtain walling. Alternatively, the rate can be related to the metre lengt
24、h of joint. 4 EN 12152:2002 (E) 3.5 f xed joint all joints except openable joints of the curtain walling (see Figure 3) 3.6 fixed joint length sum of the length of all fixed joints within the curtain walling measured along the line of the air seal/barrier. Where a window is included within the curta
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN121522002ENCURTINWALLINGAIRPERMEABILITYPERFORMANCEREQUIREMENTSANDCLASSIFICATION 幕墙 透气 率性 要求 分类 PDF

链接地址:http://www.mydoc123.com/p-705909.html