EN 1191-2012 en Windows and doors - Resistance to repeated opening and closing - Test method《窗户和门 重复开闭阻力 试验方法》.pdf
《EN 1191-2012 en Windows and doors - Resistance to repeated opening and closing - Test method《窗户和门 重复开闭阻力 试验方法》.pdf》由会员分享,可在线阅读,更多相关《EN 1191-2012 en Windows and doors - Resistance to repeated opening and closing - Test method《窗户和门 重复开闭阻力 试验方法》.pdf(58页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationWindows and doors Resistance to repeated opening and closing Test methodBS EN 1191:2012BS EN 1191:2012National forewordThis British Standard is the UK implementation of EN 1191:2
2、012. It supersedes BS EN 1191:2000 which is withdrawn.The UK participation in its preparation was entrusted by Technical Committee B/538, Doors, windows, shutters, hardware and curtain walling, to Subcommittee B/538/1, Windows and doors.A list of organizations represented on this subcommittee can be
3、 obtained on request to its secretary.BSI, as a member of CEN, is obliged to publish EN 1191 as a British Standard. However, attention is drawn to the fact that during the development of this European Standard, the UK committee voted against its approval as a European Standard.The reason for this vo
4、te by the UK committee B/538, Doors, windows, shutters, hardware and curtain walling, is due to concerns regarding the Test order in clause H.4.1. It is not clear whether the door should be returned to the closed position (H.2.7), closed and fastened position (H.2.8) or closed, fastened and locked p
5、osition (H.2.9) at the end of each cycle. Therefore, it is of the opinion of the UK committee that the relevant closed condition in the Test order in clause H.4.1 could be clarified.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its
6、 correct application. The British Standards Institution 2013. Published by BSI Standards Limited 2013ISBN 978 0 580 73952 1ICS 91.060.50Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and
7、 Strategy Committee on 31 May 2013.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDEUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 1191 December 2012 ICS 91.060.50 Supersedes EN 1191:2000English Version Windows and doors - Resistance to repeated opening and closi
8、ng - Test method Fentres et portes - Rsistance louverture et fermeture rpte - Mthode dessai Fenster und Tren - Dauerfunktionsprfung - PrfverfahrenThis European Standard was approved by CEN on 27 October 2012. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate t
9、he conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standar
10、d exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the nation
11、al standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slova
12、kia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2012 CEN All rights of exploitation in any form and by any means reserved wo
13、rldwide for CEN national Members. Ref. No. EN 1191:2012: EBS EN 1191:2012EN 1191:2012 (E) 2 Contents Page Foreword 4Introduction .51 Scope 62 Normative references 63 Terms and definitions .74 Test equipment 94.1 Test rig 94.2 Operating equipment .94.3 Measuring equipment 94.4 Velocity measurement 10
14、5 Test requirements . 105.1 General . 105.2 Number of cycles 105.3 Reference velocity 105.4 Rest time 115.5 Operation of the fastening systems 116 Preparation for testing . 127 Test procedure 127.1 Pre-test operation . 127.2 Initial measurements 137.3 General cycle description 137.4 Measurements and
15、 maintenance 147.5 Stroke . 157.6 Special cases 157.7 Final measurements . 158 Test results 159 Test report . 16Annex A (normative) Test procedures for Tilt and Turn, Tilt-First, Turn-Only or Tilt-Only windows and door-height windows 17A.1 Scope . 17A.2 General . 17A.3 Testing . 17Annex B (normative
16、) Test procedures for Sliding, Lift and Slide or Lift and Slide and Tilt windows and door-height windows 23B.1 Scope . 23B.2 Terms and definitions 23B.3 General . 24B.4 Testing . 24Annex C (normative) Test procedures for Tilt and Slide windows and door-height windows 28C.1 Scope . 28C.2 Terms and de
17、finitions 28C.3 General . 29C.4 Testing . 29Annex D (normative) Test procedures for Fold and Slide windows and door-height windows 34D.1 Scope . 34BS EN 1191:2012EN 1191:2012 (E) 3 D.2 General . 34D.3 Testing . 34Annex E (normative) Test procedures for horizontal or vertical pivot windows and door-h
18、eight windows . 37E.1 Scope . 37E.2 Terms and definitions 37E.3 General . 38E.4 Testing . 38Annex F (normative) Test procedures for Vertical Sliding windows 40F.1 Scope . 40F.2 Terms and definitions 40F.3 General . 41F.4 Testing . 41Annex G (normative) Test procedures for side-hung and top-hung wind
19、ows, opening outwards (including reversible windows) . 43G.1 Scope . 43G.2 Terms and definitions 43G.3 General . 44G.4 Testing . 44Annex H (normative) Test procedures for side-hung pedestrian doorsets excluding power operated doors 46H.1 Scope . 46H.2 Terms and definitions 46H.3 General . 47H.4 Test
20、ing . 49Annex I (normative) Test procedures for power-operated (automatic) side-hung single action pedestrian doorsets . 52I.1 Scope . 52I.2 Terms and definitions 52I.3 General . 52I.4 Testing Test order 52Bibliography . 54BS EN 1191:2012EN 1191:2012 (E) 4 Foreword This document (EN 1191:2012) has b
21、een prepared by Technical Committee CEN/TC 33 “Doors, windows, shutters, building hardware and curtain walling”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the la
22、test by June 2013, and conflicting national standards shall be withdrawn at the latest by June 2013. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such
23、patent rights. This document supersedes EN 1191:2000. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association. The most important changes compared with the previous version EN 1191:2000 are: reference velocities for manually ope
24、ration scaled according to weight; different velocities for translatory, rotatory and tilt movement; force level for operation of fastening system clearly described; more precise description of the testing cycles; minor mode of operation and cleaning and maintenance mode of operation defined; termin
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN11912012ENWINDOWSANDDOORSRESISTANCETOREPEATEDOPENINGANDCLOSINGTESTMETHOD 窗户 重复 开闭 阻力 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-705713.html