EN 1076-2009 en Workplace exposure - Procedures for measuring gases and vapours using pumped samplers - Requirements and test methods《工作场所暴露 泵送样品用测量气体和蒸气用程序 要求和试验方法》.pdf
《EN 1076-2009 en Workplace exposure - Procedures for measuring gases and vapours using pumped samplers - Requirements and test methods《工作场所暴露 泵送样品用测量气体和蒸气用程序 要求和试验方法》.pdf》由会员分享,可在线阅读,更多相关《EN 1076-2009 en Workplace exposure - Procedures for measuring gases and vapours using pumped samplers - Requirements and test methods《工作场所暴露 泵送样品用测量气体和蒸气用程序 要求和试验方法》.pdf(46页珍藏版)》请在麦多课文档分享上搜索。
1、BS EN 1076:2009ICS 13.040.30NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDWorkplace exposure Procedures formeasuring gasesand vapours usingpumped samplers Requirements and testmethodsThis British Standardwas published under theauthority of the StandardsPolicy
2、and StrategyCommittee on 31 March2010. BSI 2010ISBN 978 0 580 58633 0Amendments/corrigenda issued since publicationDate CommentsBS EN 1076:2009National forewordThis British Standard is the UK implementation of EN 1076:2009. Itsupersedes BS EN 1076:1997 which is withdrawn.The UK participation in its
3、preparation was entrusted to TechnicalCommittee EH/2/2, Work place atmospheres.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisionsof a contract. Users are responsible for its correc
4、t application.Compliance with a British Standard cannot confer immunityfrom legal obligations.BS EN 1076:2009EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 1076 December 2009 ICS 13.040.30 Supersedes EN 1076:1997English Version Workplace exposure - Procedures for measuring gases and vapours us
5、ing pumped samplers - Requirements and test methods Exposition sur les lieux de travail - Procdures pour le mesurage des gaz et vapeurs laide de dispositifs de prlvement par pompage - Exigences et mthodes dessaiExposition am Arbeitsplatz - Messung von Gasen und Dmpfen mit pumpenbetriebenen Probenahm
6、eeinrichtungen - Anforderungen und Prfverfahren This European Standard was approved by CEN on 1 November 2009. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alte
7、ration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by tra
8、nslation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germ
9、any, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG
10、 Management Centre: Avenue Marnix 17, B-1000 Brussels 2009 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 1076:2009: EBS EN 1076:2009EN 1076:2009 (E) 2 Contents Page Foreword 3Introduction .41 Scope 52 Normative references 53 Term
11、s and definitions .54 Symbols and abbreviated terms 55 Types of samplers .76 Requirements .76.1 General 76.2 Sampler requirements .76.3 Measuring procedure requirements . 107 General test conditions 127.1 Reagents 127.2 Apparatus 127.3 Independent method 137.4 Generation of the calibration gas mixtu
12、re . 138 Test methods . 148.1 General . 148.2 Sampler test methods 148.3 Measuring procedure test methods 158.4 Uncertainty of measurement . 229 Test report . 23Annex A (informative) Examples for the determination of the breakthrough volume 24A.1 Direct method 24A.2 Chromatographic method 24Annex B
13、(informative) Estimation of uncertainty of measurement . 26B.1 General . 26B.2 Uncertainty associated with sampled air volume . 26B.3 Uncertainty associated with sampling efficiency 28B.4 Uncertainty associated with sample storage and transportation 28B.5 Uncertainty associated with method recovery
14、28B.6 Uncertainty associated with method variability 32B.7 Calculation of combined standard uncertainty . 35Annex C (informative) Example of estimation of expanded uncertainty 37Bibliography . 41BS EN 1076:2009EN 1076:2009 (E) 3 Foreword This document (EN 1076:2009) has been prepared by Technical Co
15、mmittee CEN/TC 137 “Assessment of workplace exposure to chemical and biological agents”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by June 2010, and con
16、flicting national standards shall be withdrawn at the latest by June 2010. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This docume
17、nt supersedes EN 1076:1997. The major technical changes between this European Standard and the previous edition are as follows: a) adaptation of the framework for assessing the performance of procedures for measuring gases and vapours against the general requirements for the performance of procedure
18、s for measuring chemical agents in workplace atmospheres as specified in EN 482; b) revision of the calculation model for the uncertainty of measurement to comply with EN 482 and ENV 13005; c) modification of the classification scheme for sampler types; d) deletion of the informative annexes on the
19、evaluation of pumped samplers by means of field tests. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, Fran
20、ce, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 1076:2009EN 1076:2009 (E) 4 Introduction This European Standard provides a framewo
21、rk for assessing the performance of procedures for measuring gases and vapours against the general requirements for the performance of procedures for measuring chemical agents in workplace atmospheres as specified in EN 482. It enables manufacturers and users of pumped samplers and developers and us
22、ers of procedures for measuring gases and vapours to adopt a consistent approach to method validation. BS EN 1076:2009EN 1076:2009 (E) 5 1 Scope This European Standard specifies performance requirements and test methods under prescribed laboratory conditions for the evaluation of pumped samplers use
23、d in conjunction with an air sampling pump and of procedures using these samplers for the determination of gases and vapours in workplace atmospheres. This European Standard is applicable to pumped samplers and measuring procedures using these samplers in which sampling and analysis are carried out
24、in separate stages. This European Standard is not applicable to: pumped samplers which are used for the direct determination of concentrations, for example, length-of-stain detector tubes; samplers which rely on sorption into a liquid, and subsequent analysis of the solution (bubblers). 2 Normative
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN10762009ENWORKPLACEEXPOSUREPROCEDURESFORMEASURINGGASESANDVAPOURSUSINGPUMPEDSAMPLERSREQUIREMENTSANDTESTMETHODS

链接地址:http://www.mydoc123.com/p-705528.html