EN 1063-1999 en Glass in Building - Security Glazing - Testing and Classification of Resistance Against Bullet Attack《建筑玻璃 安全玻璃窗 抗子弹攻击的试验和分类》.pdf
《EN 1063-1999 en Glass in Building - Security Glazing - Testing and Classification of Resistance Against Bullet Attack《建筑玻璃 安全玻璃窗 抗子弹攻击的试验和分类》.pdf》由会员分享,可在线阅读,更多相关《EN 1063-1999 en Glass in Building - Security Glazing - Testing and Classification of Resistance Against Bullet Attack《建筑玻璃 安全玻璃窗 抗子弹攻击的试验和分类》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、STD=BSI BS EN 1063-ENGL 2000 m Lb24669 0860404 TTL I BRITISH STANDARD Glass in building - Security glazing - Testing and classification of resistance against bullet attack The European Standard EN 1063:1999 has the status of a British Standard ICs 13.310; 81.040.20 NO COPYING WITHOUT BSI PERMISSION
2、EXCEPT AS PERMIITED BY COPYRIGHT LAW 5s EN .063:2000 STD=BSI BS EN LOb3-ENGL 2000 Lb24bb9 0860405 938 = been prepared under the direction of the Sector Committee for Building and Civil Engineering, was published under the authorily of the Standards Committee and comes into effect on 15 July Zoo0 Amd
3、. No. 0 BSI 07-2000 ISBN O 580 36105 5 BS EN 1063:2000 Date Comments National foreword This British Standard is the official Engiish language version of EN 1063.1999. The UK participation in its preparation was entrusted by Technical Committee B/520, Glass and glazing in building, to Subcommittee W5
4、20/3, Security glazing, which has the responsibility to: - aid enquirers to understand the text; - present to the responsible European committee any enquiries on the - monitor related international and European developments and promuigate interpretation, or proposals for change, and keep the UK inte
5、ress informed; them in the UK A list of organizations represented on this subcommittee can be obtained on request to its secretary. This British Standard supersedes BS 5051-1: 1988 immediately for the testing and classification of glass and glasdplastics composites. BS 5051-1 wil however remain avai
6、lable for the testing and Classification of plastics glazing sheet materiais until a corresponding British Standard is published for these products. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Stan
7、dards Catalogue under the section entitled “International Standards Correspondence Index“, or by using the “Find“ facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a conkact. Users of British standards are responsible f
8、or their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, the EN titie page, pages 2 to 9 and a back cover. The BSI copyright notice displayed in this docu
9、ment indicates when the document was last issued. STDWBSI BS EN LOb3-ENGL 2000 = Lb24bb9 08b040b 874 H EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 1063 November 1999 ICs 13.310; 81.040.20 English version Glass in building - Security glazing - Testing and classification of resistance against
10、 bullet attack Verre dans la construction -Vitrage de scurite - Mise essai et classification de la rsistance lattaque par balle Glas im Bauwesen - Sicherheitssonderverglasung - Prfverfahren und Klasseneinteilung fr den Widerstand gegen Beschu This European Standard was approved by CEN on 16 April 19
11、99. CEN members are bound to comply with the CENICENELEC Internal Regulations which stipulate the conditions for giving this Europmn Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning sich national standards may be obtained o
12、n application to the Central Secretariat or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by tmslation under the responsibility of a CEN member into its own language and notified to the Central Secretariat
13、has the same status as he official versions. CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMI
14、TTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Central Secretariat: rue de Stassart, 36 B-1050 Brussels O 1999 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 1063:1999 E STD-BSI BS EN LOb3-E
15、NGL 2000 m Lb24bb9 08b0407 700 m Page 2 EN 1063:1999 Content Page Foreword 3 1 2 3 4 5 6 7 7.1 7.2 8 9 Scope . 3 Normative references . _ . 3 Definitions . 4 Classification of the levels of bullet-resistance and test conditions 4 Test pieces for type testing 6 Performance requirements ._ . 6 Test me
16、thod . 7 Apparatus . 7 Test performance . 8 Report 9 Marking . 9 (o BSI 07-2000 STD-BSI BS EN 1063-ENGL 2000 1bZ4bb7 0860408 b43 Page 3 EN 1063:1999 Foreword This European Standard has been prepared by Technical Committee CENEC 129 “Glass in building“, the secretariat of which is held by IBN. This E
17、uropean Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by May 2000, and conflicting national standards shall be withdrawn at the latest by May 2000. According to the CENKENELEC Internal Regulations, the national
18、standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and the United Kingdom. The ma
19、in requirement for bullet-resistant glazing is to prevent the passage of projectiles from various types of weapon. The classification of bullet-resistance of glazing in this standard is a technical classification, based on common weapons and ammunition, in order of attacking power. As the variety of
20、 weapons and ammunition does not allow them all to be taken into account, a selection had to be made that covers most weapons and ammunition. The choice of bullet-resistant glazing is established by the user for each individual case. 1 Scope This standard specifies performance requirements and test
21、methods for the classification of the bullet- resistance of glass (consisting of one or more layers of glass) and glass/plastic composites. NOTE 1 : The term “bullet-resistant glazing“ applies to products that have the obvious characteristics of glass, but it is understood to include also laminated
22、products of glass and plastics. This standard applies to: -attack by handguns, rifles and shotguns; -glazing in buildings, for interior and exterior use; NOTE 2: For interior use at a temperature of (18 f 5) OC. For exterior use the influence of outside temperature and weathering should be considere
23、d. Any additional requirements should be agreed between the purchaser and the vendor. -the glazing product itself, assuming proper fixing. NOTE 3: The protection provided by bullet-resistant glazing depends not only on the product itself, but also upon the design and fixing of the glass. 2 Normative
24、 references This European Standard incorporates by dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN10631999ENGLASSINBUILDINGSECURITYGLAZINGTESTINGANDCLASSIFICATIONOFRESISTANCEAGAINSTBULLETATTACK 建筑

链接地址:http://www.mydoc123.com/p-705499.html