EN 1026-2016 en Windows and doors - Air permeability - Test method《门窗-透气性-试验方法》.pdf
《EN 1026-2016 en Windows and doors - Air permeability - Test method《门窗-透气性-试验方法》.pdf》由会员分享,可在线阅读,更多相关《EN 1026-2016 en Windows and doors - Air permeability - Test method《门窗-透气性-试验方法》.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、BS EN 1026:2016Windows and doors Airpermeability Test methodBSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06BS EN 1026:2016 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 1026:2016.It supersedes BS EN 1026:2000 which is withdraw
2、n.The UK participation in its preparation was entrusted to TechnicalCommittee B/538/1, Windows and doors.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are
3、responsible for its correctapplication. The British Standards Institution 2016.Published by BSI Standards Limited 2016ISBN 978 0 580 82209 4ICS 91.060.50Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStand
4、ards Policy and Strategy Committee on 30 June 2016.Amendments/corrigenda issued since publicationDate T e x t a f f e c t e dBS EN 1026:2016EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 1026 March 2016 ICS 91.060.50 Supersedes EN 1026:2000English Version Windows and doors - Air permeability -
5、 Test method Fentres et portes - Permabilit lair - Mthode dessai Fenster und Tren - Luftdurchlssigkeit - Prfverfahren This European Standard was approved by CEN on 9 January 2016. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
6、 European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official ve
7、rsions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austri
8、a, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden,
9、 Switzerland, Turkey andUnited Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2016 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN na
10、tional Members. Ref. No. EN 1026:2016 EBS EN 1026:2016EN 1026:2016 (E) 2 Contents Page European foreword . 3 1 Scope 5 2 Normative references 5 3 Terms and definitions . 5 4 Principle of test 6 5 Test apparatus 6 6 Preparation of test specimen 7 7 Test procedure . 7 7.1 Preliminaries 7 7.2 Air perme
11、ability of test chamber 7 7.2.1 General 7 7.2.2 Test chamber with known air permeability 7 7.2.3 Test chamber with unknown air permeability 7 7.3 Overall air permeability of test specimen and the test chamber positive pressures . 8 7.3.1 General 8 7.3.2 Measurement of air permeability for windows an
12、d external pedestrian doorsets 8 7.3.3 Measurement of air permeability for internal pedestrian doorsets 8 7.4 Overall air permeability of test specimen and the test chamber negative pressures 8 8 Test result 8 9 Test report . 9 Annex A (informative) Test pressure sequences . 16 Bibliography . 17 BS
13、EN 1026:2016EN 1026:2016 (E) 3 European foreword This document (EN 1026:2016) has been prepared by Technical Committee CEN/TC 33 “Doors, windows, shutters, building hardware and curtain walling”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a nationa
14、l standard, either by publication of an identical text or by endorsement, at the latest by September 2016, and conflicting national standards shall be withdrawn at the latest by September 2016. Attention is drawn to the possibility that some of the elements of this document may be the subject of pat
15、ent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 1026:2000. The revision of this European Standard clarifies the test method and does not affect existing test evidence of EN 1026:2000. In comparison with EN 1026:2
16、000, the following significant changes were made: a) Clause 2: Deletion of “Normative references“; b) Clause 3: Supplement of definition “closing condition”; c) Sub-clause 3.2: Simplification of definition “test pressure”; d) Sub-clause 3.4 and 3.5: Revision of definition opening joint“; e) Sub-clau
17、se 5.4: Revision of definition accuracy“; f) Sub-clause 7.3: Addition of closing condition“; g) Sub-clause 7.3: Separate test methods for measurement of air permeability for windows and external pedestrian doorsets in 7.3.2 and for internal pedestrian doorsets in 7.3.3; h) Clause 9: Supplement of ne
18、cessary description of test specimen; i) Clause 9: Revision of Figures 1 and 2; j) Clause 9: Supplement of figures: - Figure 3 - Sliding door test specimen; - Figure 4 - Single leaf test specimen with fixed glazing; - Figure 5 - Single leaf test specimen with fixed glazing, extension profiles and sh
19、utter boxes; - Figure 6 - External / internal pedestrian doorset; k) Revision of Annex A: Separation of figures into Figures A.1 and A.2. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard:
20、Austria, Belgium, Bulgaria, BS EN 1026:2016EN 1026:2016 (E) 4 Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Rom
21、ania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 1026:2016EN 1026:2016 (E) 5 1 Scope This European Standard defines the test method to be used to determine the air permeability of completely assembled windows and doorsets of any material, when submitted to p
22、ositive or negative test pressures. This test method is designed to take account of conditions in use, when the window or doorset is installed in accordance with the manufacturers specification and the requirements of relevant European Standards and codes of practice. This European Standard does not
23、 apply to the joints between the window or door frame and the building construction. 2 Normative references Not applicable. 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 closing condition 3.1.1 closed movable part rest in or at the fixed pa
24、rt in a way in which they may be fastened (latched and/or locked) 3.1.2 fastened where the movable part is restrained at one or more points and shall be described by at least one of the two as listed below: 3.1.2.1 latched movable part is returned to its closed position and restrained by either a) a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN10262016ENWINDOWSANDDOORSAIRPERMEABILITYTESTMETHOD 门窗 透气性 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-705337.html