EEMUA PUB NO 182-2004 SPECIFICATION FOR INTEGRAL BLOCK AND BLEED VALVE MANIFOLDS FOR DIRECT CONNECTION TO PIPEWORK (INCORPORATING INFORMATION SHEET NO 20 APPLICATION GUIDELINES 2nd.pdf
《EEMUA PUB NO 182-2004 SPECIFICATION FOR INTEGRAL BLOCK AND BLEED VALVE MANIFOLDS FOR DIRECT CONNECTION TO PIPEWORK (INCORPORATING INFORMATION SHEET NO 20 APPLICATION GUIDELINES 2nd.pdf》由会员分享,可在线阅读,更多相关《EEMUA PUB NO 182-2004 SPECIFICATION FOR INTEGRAL BLOCK AND BLEED VALVE MANIFOLDS FOR DIRECT CONNECTION TO PIPEWORK (INCORPORATING INFORMATION SHEET NO 20 APPLICATION GUIDELINES 2nd.pdf(36页珍藏版)》请在麦多课文档分享上搜索。
1、THE ENGINEERING EQUIPMENT AND MATERIALS USERS ASSOCIATION SPECIFICATION FOR INTEGRAL BLOCK AND BLEED VALVE MANIFOLDS FOR DIRECT CONNECTION TO PIPEWORK (2nd Edition) PUBLICATION No 182 : 2004 CORRIGEN DA, JUNE 2004 The corrections/omissions set out below are issued under the authority of the EEMUA Va
2、lves Technical Committee which has responsibility for the maintenance of this publication. 1: 95.2.1 In the second line, amend the date of ASME B16.34 to 1996. 2: 95.4.4 In the first line, after forging insert: or casting,. 3: Section 11, S2 Surface Examination At the end of the subsection insert ad
3、ditional sentence: The acceptance standard for all items less than DN 50 shall be no recordable defects . EEMUA Jun. 2004 PUB 182 CORR THE ENGINEERING EQUIPMENT AND MATERIALS USERS ASSOCIATION SPECIFICATION FOR INTEGRAL BLOCK AND BLEED VALVE MANIFOLDS FOR DIRECT CONNECTION TO PIPEWORK (INCORPORATING
4、 INFORMATION SHEET NO 20: APPLICATION GUIDELINES) (2nd EDITION) PUBLICATION No 182 : 2004 Copyright O 2004 The Engineering Equipment and Materials Users Association ISBN O 85931 125 2 3rd Floor, 20 Long Lane LONDON ECIA 9HL Telephone: 020 7796 1293 Fax: 02077961294 e-mail: website: w.eemua.co. u k s
5、aieseem u a. Co. u k . . . . . . , . ,.,.:.:;:?$s . . . . . $y .A 30 J minimum. 6.10 The seals and gland packings of high temperature (as defined in 5.1.2 (b) manifolds shall be of graphite incorporating a passivating corrosion inhibitor. 6.1 1 Where the seat of metal seated valves is formed from an
6、d integral with the material of the body, the disc or gate shall be harder than the seat. 6.12 Where specified on the data sheet or where dirty or abrasive service is specified, manifolds whose outlets are connected to process pipework shall be provided with main isolating valves having gates, balls
7、, plugs and seats hard-faced with tungsten carbide, Stellite etc. 7 7.1 7.2 7.3 8 8.1 FIRE SAFETY Manifolds incorporating thermoplastic or elastomeric seats or seals shall be covered by fire type-test certification in accordance with IS0 10497, BS 6755 Pt 2,* API Spec. 6FA, API Std 607 or an alterna
8、tive standard acceptable to the purchaser. The complete manifold shall be fire tested. * At the time of writing, IS0 10497 was undergoing revision for reissue as EN IS0 10497. Once the BS EN IS0 is published, BS 6755 Pt 2 will be withdrawn. A test on one valve within a fully assembled manifold quali
9、fies other valves of a similar design subject to the restrictions on size, pressure rating and materials imposed by the relevant fire type-test standard. Manifolds incorporating metal-to-metal sealing and graphite seals may be acceptable without fire test certification by agreement with the purchase
10、r. TESTING The fully assembled manifold shall be hydrostatically tested in accordance with IS0 5208 subject to the following amendments: The test medium shall be fresh water containing, where appropriate, a water-soluble rust inhibitor and wetting agent. In the case of stainless steel manifolds, the
11、 chloride content shall be 20 ppm max. and the pH between 6 and 8.5. Vent connections and threaded outlet connections shall be plugged during the test. 0 Test duration shall be a minimum of 2 min. There shall be no detectable leakage from gland packings or body joints during the test. 9 Manifold bod
12、ies shall be free from external constraints applied in the direction of the pipe axis during the hydrostatic shell test. 8.2 Following hydrostatic testing and with the manifold at its rated pressure, each valve unit shall be operated (opened and closed) three times by hand to demonstrate easy and co
13、nsistent operation. Each valve unit shall then be seat leak tested in accordance with IS0 5208 subject to the following amendments: The test medium shall be: (1) for manifolds incorporating ball or slab gate valves, air or nitrogen at 6 f 1 bar; (2) for all other manifolds and valve types, liquid at
14、 1 .I x rated pressure. Test liquid shall be as in 8.1 above. 0 Test duration shall be a minimum of 1 min. 0 Stabilisation time shall be a maximum of 1 min. Allowable leak rates: (1) soft-seated valves, plug valves and all needle valves-Rate A (2) metal-seated ball and gate valves-Rate C. Each valve
15、 seat shall be tested individually. Testing shall be conducted in a direction from inlet to outlet only, unless otherwise specified by the purchaser, or where manifolds are intended to be fully bi-directional. 8.3 Test equipment shall have been calibrated in accordance with a recognised standard as
16、required by the manufacturers independently assessed and approved quality system, with the results recorded. The accuracy of pressure gauges used in testing shall be in accordance with EN 837-1 Table 1 1, class 1.6 or better. The gauges shall display the test pressure between 25% and 75% of full gau
17、ge range, and have a minimum face diameter of 150 mm. 9 MARKING 9.1 The manifold blocks shall be marked (by vibro-etching or low stress stamping) with the information listed below. Alternatively this information may be chemically etched, vibro- etched or stamped on a stainless steel nameplate attach
18、ed by screws or driven pins. Manufacturers name or trademark manufacturers figure or type number material specification of body and connections (eg Al 05) rating based on inlet flange (eg CI. 900) minimum and maximum working temperatures, from 5.1.2, in OC (e.9. 2Cb120 C) unique serial number IS0 15
19、156 or NACE MR0103 as appropriate min. flow passage bore (mm) with letter S if straight through port (e.9. IO S). For items being put into service in the EEA, marking shall include the CE mark, PED conformity assessment category and module, and, where appropriate, notified body ID. 9.2 Connections s
20、hall be marked as follows: nominal size of inlet flange size, thread type etc. of outlet connection size, thread type etc. of vent connection. 10 10 DOCUMENTATION 10.1 Purchasers Data Sheet As part of the order, the purchaser will provide the manufacturer with a data sheet specifying the requirement
21、s. A model data sheet is given in Appendix C. 10.2 Documentation to be Supplied and/or Retained by the Manufacturer 10.2.1 Material and Test Certification 10.2.1 .I All manifolds shall be certified as complying with this Specification, the requirements of the order, and, for items put into service i
22、n the EEA, the requirements of the PED. 10.2.1.2 Material of the manifold block, valve bonnets and other pressure retaining parts shall be certified in accordance with EN 10204 and provided with a Type 3.1 B certificate. 10.2.1.3 Material of other wetted parts and any bolting shall be provided with
23、a Type 2.2 certificate. 10.2.1.4 All manifolds shall have a certificate confirming satisfactory completion of hydrostatic and seat leak tests. 10.2.1.5 All mill certificates shall be originals or authenticated copies unless otherwise agreed with purchaser. 10.2.2 Traceability Traceability of the man
24、ifold block, valve bonnets and other pressure retaining parts (with the exception of bolting) shall be maintained such that cast / heat numbers can be accessed from the serial number. 10.2.3 Other Documentation 10.2.3.1 Copies of the certificate of conformity and test certificate shall be supplied w
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EEMUAPUBNO1822004SPECIFICATIONFORINTEGRALBLOCKANDBLEEDVALVEMANIFOLDSFORDIRECTCONNECTIONTOPIPEWORKINCORPORATINGINFORMATIONSHEETNO20APPLICATIONGUIDELINES2NDPDF

链接地址:http://www.mydoc123.com/p-704961.html