1、STD-EIA EIA-815-ENGL 199q aii 3234600 Ob24446 031 m EIA STANDARD Miniature Aluminum Electrolytic Capacitor (Leaded) Qualification Specification - EIA-815 AUGUST 1999 ELECTRONIC INDUSTRIES ALLIANCE ELECTRONIC COMPONENTS, ASSEMBLIES, EQUIPMENT approval levels and sampling plan Page 1 1 1 1 1 1 1 2 2 2
2、 2 2 2 2 2 2 2 3 3 3 3 3 3 4 4 4 4 4 5 5 5 6 6 6 6 7 7 7 7 7 3 I O STD*EIA EIA-815-ENGL LSqq 3234600 Ob24449 840 . Foreword This specification was prepared by the P-2.4 Subcommittee on Aluminum Electrolytic Capacitors of the Electronic Industries Alliances sector Electronic Components, Assemblies, E
3、quipment b) c) d) e) f) g) the parts shall be subjected to rated voltage for 2000 hours at rated operating temperature (85 OC, 105 OC, or 125 “C ); test time may be extended at the prerogative of the user or the supplier; measurements shall be taken at O h, 500 h, 1000 h, and 2000 h; extended testin
4、g should have measurements at 1000 hour increments; capacitance change shall be 5 20% from initial limits; dissipation factor (DF) shall be 5 200% of initial limit; equivalent series resistance (ESR) shall be 5 200% of initial limit; DC leakage current shall meet initial limit. 4.5 Load humidity tes
5、t Capacitors shall be tested per MIL-STD-202, Method 103B, except: a) preconditioning is required; b) c) d) e) f) g) apply maximum rated voltage for 500 hours; measurements shall be taken at O hours and 500 hours; capacitance change shall be 5 20% from initial limits; DF shall be 5 200% of initial l
6、imit; ESR shall be 5 200% of initial limit; DC leakage current shall meet initial limit. 4.6 Thermal shock Capacitors shall be tested per MIL-STD-202, Method 107( air-to-air). a) preconditioning is required; b) c) d) e) f) the maximum and minimum temperatures will be per the product specification; t
7、he parts shall be subjected to 300 cycles; the maximum transfer time shall be 20 seconds; the dwell time shall be 30 minutes; capacitance, DF, ESR, and leakage shall be measured after testing and meet initial limits as specified in the detailed specification. STD=EIA EIA-L5-ENGL L999 II 3234600 062i
8、r454 LOB II EIA-8 15 Miniature aluminum electrolytic capacitor qualification specification Page 5 4.7 Exposure (storage) Capacitors shaII be tested per MIL-STD-202, Method 108, with the following exceptions: a) preconditioning is required; b) c) d) capacitors shall be unpowered; e) f) g) twenty samp
9、les shall be stored at maximum and twenty samples at minimum temperature per product specification; exposure time shall be 1000 hours; capacitors shall meet the visual requirements per 4.3; capacitance change shall be 5 10% from initial limits.; DF, ESR and leakage shall meet initial limit. 4.8 Surg
10、e voltage Capacitors shall be tested per the following procedure: a) preconditioning is required; b) c) d) test procedure; capacitance shall be measured and samples identified; surge voltage shall be a minimum of 1.15 rated voltage for capacitors rated 5 315 V; capacitors rated at 315 V shall be tes
11、ted at a minimum of 1.10 rated voltage; Capacitors, while mounted in the vertical position, shall be subjected to 1000 cycles of DC surge voltage as specified in the table below. Nonpolarized styles shall be subjected to 1000 cycles in each direction. Each cycle shall consist of a 30 second surge vo
12、ltage application, followed by a 5.5 minute discharge period. Voltage application shall be made through a resistor (1000 ohms f 50 ohms for capacitance values of less than 2500 pF and 100 ohms k 5 ohms for capacitance values of 2500 pF and greater) in series with the capacitor and the voltage source
13、. Each surge voltage cycle shall be performed in such a manner that the capacitor is discharged through the resistor at the end of the 30 second application. The test shall be terminated on the discharge position of the cycle. a) b) capacitance change from initial value shall not exceed r 15%; DF, E
14、SR and DC leakage current must meet initial limits. 4.9 Vibration Capacitors shall be tested per MIL-STD-202, Method 204, Test Condition D, except: preconditioning is required; capacitors shall be mounted on a 203 mm x 127 mm ( 8 in x 5 in ) PCB, 0.79 mm(0.03lin) thick, with 7 secure points on one 2
15、03 mm(8 in) side and 2 secure points on corners of opposite sides. Parts shall be mounted within 51mm(2 in) from any secure point. Capacitors shall be soldered and attached to the board as normally intended. The body of the capacitor shall be rigidly secured to prevent lead breakage; leaded capacito
16、rs shall subjected to 12 cycles in each of three orientations; the capacitors shall be subjected to a simple harmonic motion having an amplitude of either 1.5 mm (0.06 in) double amplitude (maximum total excursion) or 20.0 g, (peak) , whichever is less; frequency shall be varied between 10 Hz and 20
17、00 Hz. The entire frequency range shall be traversed in 20 minutes; during the last cycle, electrical characteristics (capacitance, DF and ESR) shall be monitored to determine stability; post-test requirements. Not applicable, since the same parts will be used for shock. STD-EIA EIA-815-ENGL 3777 M
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECAEIA8151999MINIATUREALUMINUMELECTROLYTICCAPACITORLEADEDQUALIFICATIONSPECIFICATION 微型 铝电解电容器 合格 规范 PDF

链接地址:http://www.mydoc123.com/p-704493.html