ECA EIA-540B0AA-A-2001 Detail Specification for Production Ball Grid Array (BGA) High Pin Count (1089 Pins and Greater) Socket for Use in Electronic Equipment (Revision of EIA-540B.pdf
《ECA EIA-540B0AA-A-2001 Detail Specification for Production Ball Grid Array (BGA) High Pin Count (1089 Pins and Greater) Socket for Use in Electronic Equipment (Revision of EIA-540B.pdf》由会员分享,可在线阅读,更多相关《ECA EIA-540B0AA-A-2001 Detail Specification for Production Ball Grid Array (BGA) High Pin Count (1089 Pins and Greater) Socket for Use in Electronic Equipment (Revision of EIA-540B.pdf(40页珍藏版)》请在麦多课文档分享上搜索。
1、 EIA STANDARD Detail Specification for Production Ball Grid Array (BGA), High Pin Count (1089 Pins and Greater) Socket for Use in Electronic Equipment EIA-540B0AA-A (Revision of EIA-540-B0AA) October 2001 Stabilized: March 2014 EIA-540B0AA-A ANSI/EIA-540B0AA-A-2001 Approved: October 8, 2001 NOTICE E
2、IA Engineering Standards and Publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the p
3、roper product for his particular need. Existence of such Standards and Publications shall not in any respect preclude any member or nonmember of ECIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications p
4、reclude their voluntary use by those other than ECIA members, whether the standard is to be used either domestically or internationally. Standards and Publications are adopted by ECIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, ECIA does not ass
5、ume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the Standard or Publication. This EIA Standard is considered to have International Standardization implication, but the International Electrotechnical Commission activity has not progressed to the p
6、oint where a valid comparison between the EIA Standard and the IEC document can be made. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate saf
7、ety and health practices and to determine the applicability of regulatory limitations before its use. (From Standards Proposal No. 5328.11, formulated under the cognizance of the CE-2.0 Committee on EIA National Connector and Socket Standards). Published by Electronic Components Industry Association
8、 2014 Engineering Department 2214 Rock Hill Road, Suite 265 Herndon, VA 20170 EIA-540BOAA-A Page 1 Systems Standard Organization ELECTRONICS INDUSTRIES ALLIANCE GENERIC SPECIFICATION NUMBER EIA-5400000-A Socket Outline Drawing See figures 1 and 2 for dimensional information. Tolerances: 2 0.13 mm (2
9、 0.005 in) on all figures except where noted. DETAIL SPECIFICATION NUMBER EIA-540BOAA-A SECTIONAL SPECIFICATION NUMBER EIA-540B000 BLANK DETAIL SPECIFICATION NUMBER None Product Description This specification is for use with BGA devices described in Annex F. Product Requirements The complete require
10、ments for the interconnect system shall consist of this Detail Specification and where applicable the latest issue of EIA-540B000. TYPICAL CONSTRUCTION Contact Material : Copper alloy Outermost Contact Finish: Tin-lead Termination Finish : Tin-lead Insulator Material : High temperature thermoplastic
11、 APPLICATION/ASSESSMENT LEVEL For use in commercial, computer, and communications equipment. EIA-540BOAA-A Page 2 1 Scope and purpose This specification covers interconnect systems typically used for production ball grid array (BGA) devices with pin counts of 1089 and greater. 1.2 Purpose The purpos
12、e of this detail specification is to provide all information required for the identification and assessment of the BGA socket described herein. The information, contained herein or by reference, is complete and sufficient for inspection purposes. 2 Normative references The following standards contai
13、n provisions that, through reference in this text, constitute provisions of this standard. At the time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this standard are encouraged to investigate the possibility of applying
14、the most recent editions of the standards indicated below. EIA-364-C, Electrical Connector Test Procedures Including Environmental Classifications (December, 1994). EIA-5400000-A , Generic Specification (August, 1996). EIA-540B000, Sectional Specification (November, 1997). Socket details Contact pla
15、ting The outermost plating of the contact area shall be tin-lead or tin-lead compatible and shall satisfy the requirements specified in the qualification test sequence. The contact plating systems utilized shall be compatible to the systems they are mated to, such as: a) Tin-lead b) Other NOTE: Gold
16、-plated contact surfaces mated to tin-lead plated contact surfaces are not an acceptable plating combination. EIA-540BOAA-A Page 3 3.2 Contact fiiish at the termination area shall be as indicated in Table 1. Contact finish at termination area Table 1 Contact finish at termination area Contact finish
17、 Tin-lead 3.3 Actuation method The actuation of the socket shall be as indicated in table 2. Table 2 Actuation type Actuation method ZIF with Lever Actuation 3.4 Mounting Method The mounting of the socket shall be as indicated in table 3. Table 3 Mounting method Mounting method Surface Mount Other E
18、IA-540BOAA-A Page 4 Atmospheric conditions General controlled 3.5 Socket dimensions Temperature Air Relative pressure humidity 15 OC to 35 OC 87 Wa to 107 Wa (59 OF to 95 OF) (650 mmHg to 800 mmHg) 80% or less The configuration of the BGA socket is optional within the limits of the dimensions within
19、 figure 1 and the mounting dimensions within figure 2. 3.6 Contact spacing The contact spacing shall be as indicated in table 4. Table 4 Contact spacing Contact spacing Other 4 Mating devices Mating devices shall be in accordance with JEDEC specifications. Said devices shall be internally wired in o
20、rder to perform the appropriate electrical measurements such as low-level circuit resistance (LLCR). 5 Atmospheric conditions for testing The interconnect system shall be tested at the atmospheric conditions as specified in table 5, general controlled. 40.64 (1.600) Surface Mount Amlication Solder T
21、ail Stvle 40.64 (1.600) Socket housing 33 x 33 Socket housing 50.80 (2.000) 50.80 (2.000) 25 x 25 Figure 1 Housing dimensions EIA-540BOAA-A Page 6 Socket outline I I I I I I I I I I I I I I I I I I I I I 0 o I I I I I I I I I I I I o o A Notes (Su rface mount application; a) SMT pad size b) SMT pad
22、plating : 0.86 mm +/- 0.05 mm diameter (0.034 in +/- 0.002 in diameter) : Tin-Lead Notes (Plated throuph hole annlication; a) Finished PTH size b) PTH plating : Tin-Lead : 0.86 mm +/- 0.05 mm diameter (0.034 in +/- 0.002 in diameter) Figure 2 - Recommended board pattern EIA-540BOAA-A Page 7 6 Test s
23、equence This test sequence shows all tests and the order in which they shall be carried out as well as the requirements to be met. The baseline test sequence (figure 3) illustrates the order of tests by group. In the following test sequence tables, where an EL4 test is specified without a letter suf
24、fix, the latest approved version of that test shall be used. EIA-540BOAA-A Page 8 DITIONING I LLCR SAMPLE PREPARATION LLCR DITIONING RESISTANCE I TOSOLDER LLCR HEAT I DURABILIY IR MECH. SHOCK MECH. SHOCK RANDOM VIBRATION LIFE SOLVENT THERMAL RESISTANCE I SHOCK LLCR LLCR ATC LLCR RANDOM LLCR VIBRATIO
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECAEIA540B0AAA2001DETAILSPECIFICATIONFORPRODUCTIONBALLGRIDARRAYBGAHIGHPINCOUNT1089PINSANDGREATERSOCKETFORUSEINELECTRONICEQUIPMENTREVISIONOFEIA540BPDF

链接地址:http://www.mydoc123.com/p-704403.html