ECA EIA-520E000-A-2000 Sectional Specification In-Line Switches of Certified Quality《已质量认证的直插式开关分规范》.pdf
《ECA EIA-520E000-A-2000 Sectional Specification In-Line Switches of Certified Quality《已质量认证的直插式开关分规范》.pdf》由会员分享,可在线阅读,更多相关《ECA EIA-520E000-A-2000 Sectional Specification In-Line Switches of Certified Quality《已质量认证的直插式开关分规范》.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、ANSI/EIA-520E000-A-2000 Approved: October 25,2000 EIA SPECIFICATION Sectional Specification In-Line Switches of Certified Quality EIA-520E000-A (Revision of EU-520E000) OCTOBER 2000 ELECTRONIC COMPONENTS, ASSEMBLIES degradations are not permitted. 2 General 2.1 Related Documents The following docume
2、nts of the issue in effect form a part of this specification to the extent specified herein: EIA-5200000 Generic Specification for Special Use Electromechanical Switches of Certified Quality 2.2 Terminology Terminology shall be in accordance with EIA-5200000. Terminology peculiar to detail specifica
3、tion shall be defined in those documents. Terminology peculiar to the products covered by this specification shall be defined herein. 2.3 Preferred Ratings and Characteristics Whenever possible, the values, ratings, and characteristics shall be selected from the following: 2.3.1 Preferred ratings: T
4、he electrical ratings shall be as specified in detail specifications EIA-520E000-A Page 2 2.3.1.1 Rated Voltage; The following voltage ratings are preferred; 50 V dc, 6 V dc, 20 mV dc. 2.3.1.2 Rated Current; The following current ratings are preferred; 250 mA, 100 mA, 10 mA. 2.3.2 Preferred Characte
5、ristics; 2.3.2.1 Low Temperature Rating; The following low temperature ratings are preferred; -10 OC, -25 OC, -40 OC, -55 OC. 2.3.2.2 High Temperature ratings; The following high temperature ratings are preferred; 55 OC, 70 OC, 85 oC,lOO OC, 125 OC. 2.5 Marking The switches shall be marked with the
6、following information; a) terminal or actuator identification whenever specified in b) Manufacturers name, trademark, or code identification C) Identifying number (EIA part number, manufacturers part d) Date code - the date code is a four digit number consisting the detail specification. number. num
7、ber, or users part number. of the last two digits of the year and another two digits for the week of the year. Foe example; a date code of 8822 denotes the 22nd week of 1988. Other markings may be applied to the switch provided they do not interfere with, obscure, or confuse those markings specified
8、 above. Where size, surface condition, or other design considerations will not allow full marking of the part, the markings shall be in the order of preference shown above. Any required markings which cannot be applied to the switch shall be applied to the package containing the switch. 2.6 Informat
9、ion to be Given in the Detail Specification Detail specifications shall be derived from thee relevant Blank Detail Specification and shall contain all the required information. Detail specifications shall not specify requirements inferior to those of the generic or Sectional specifications. When mor
10、e severe requirements are included, they shall be listed in the detail specification and indicated in the test schedule with an asterisk (for example). The detail specification shall contain the complete technical requirements for the inspection including the quality conformance test schedule. If th
11、e technical requirements of the generic and/or Sectional specification relative to inspection are not entirely suitable (either for technical reasons or for special applications) to the component described in the detail specification, the detail specification shall set out clearly the various amendm
12、ents which are to be made to those requirements. EIA-520E000-A Page 3 3 OUALITY ASSESSMENT PROCEDURES 3.1 Qualification Approval Procedures The qualification approval procedures shall be in accordance with EIA- 5200000 and the following additional requirements; 3.1.1 Qualification inspection tests;
13、The qualification inspection tests are described in table I herein. The minimum qualification inspection for any in- line switch shall be Groups A and B in Table I. Additional Test Groups C, D and E may be added to the qualification requirements for a specific detail specification as necessary, as c
14、an test beyond those of Table I. When Test Groups C through E are prescribed by the detail specification, the identity of the Test Group, the sequence of tests, and the minimum sample quantity shall be in accordance with Table I. When the detail specification prescribes tests not in Table I, the add
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECAEIA520E000A2000SECTIONALSPECIFICATIONINLINESWITCHESOFCERTIFIEDQUALITY 质量 认证 直插式 开关 规范 PDF

链接地址:http://www.mydoc123.com/p-704400.html