ECA EIA-468-C-2008 Lead Taping of Components in the Radial Configuration for Automatic Handling.pdf
《ECA EIA-468-C-2008 Lead Taping of Components in the Radial Configuration for Automatic Handling.pdf》由会员分享,可在线阅读,更多相关《ECA EIA-468-C-2008 Lead Taping of Components in the Radial Configuration for Automatic Handling.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、 EIA STANDARD Lead Taping of Components in the Radial Configuration for Automatic Handling EIA-468-C (Revision of EIA-468-B ) October 2013 EIA-468-CANSI/EIA-468-C-2013 Approved: December 30, 2008 Reaffirmed: October 18, 2013 NOTICE EIA Engineering Standards and Publications are designed to serve the
2、 public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standards
3、and Publications shall not in any respect preclude any member or nonmember of ECIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than ECIA members, wheth
4、er the standard is to be used either domestically or internationally. Standards and Publications are adopted by ECIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, ECIA does not assume any liability to any patent owner, nor does it assume any oblig
5、ation whatever to parties adopting the Standard or Publication. This EIA Standard is considered to have International Standardization implication, but the International Electrotechnical Commission activity has not progressed to the point where a valid comparison between the EIA Standard and the IEC
6、document can be made. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applicability of regu
7、latory limitations before its use. (From Standards Proposal No. 5263, formulated under the cognizance of the Automated Component Handling Committee). Published by Electronic Components Industry Association 2013 Engineering Department 2214 Rock Hill Road, Suite 170 Herndon, VA 20170 PLEASE! DONT VIOL
8、ATE THE LAW! This document is copyrighted by the ECIA and may not be reproduced without permission. Organizations may obtain permission to reproduce a limited number of copies through entering into a license agreement. For information, contact: IHS 15 Inverness Way East Englewood, CO 80112-5704 or c
9、all USA and Canada (1-877-413-5184), International (303-397-7956) i Lead Taping of Components in the Radial Configuration for Automatic Handling CONTENTS SECTIONS PAGE 1. INTRODUCTION AND SCOPE 1 2. NORMATIVE REFERENCES 1 3. DIMENSIONS 1 4. REQUIREMENTS 5 5. ACKNOWLEDGEMENTS 9 FIGURES AND TABLES FIG
10、URE 1 Coordinate System 1 FIGURE 2 Lead Taping Dimensions 2 FIGURE 3 Component Pitch 4 FIGURE 4 Reference Plane 5 FIGURE 5 Reel Configuration 7 FIGURE 6 Fan Fold Box Configuration 7 FIGURE 7 Reel Label Location 8 FIGURE 8 Fan Fold Box Label and Marking Locations 8 TABLE 1 Lead Taping Dimensions 3 TA
11、BLE 2 Component Pitch 4 TABLE 3 Reel Dimensions 7 TABLE 4 Fan Fold Box Dimensions 7 EIA-468-C Page 1 LEAD TAPING OF COMPONENTS IN THE RADIAL CONFIGURATION FOR AUTOMATIC HANDLING Revision of EIA Standard 468-B, formulated under the cognizance of the EIA Automated Component Handling (ACH) Committee 1.
12、 INTRODUCTION AND SCOPE This standard was formulated to provide dimensions and tolerances necessary to lead tape components in the radial format (unidirectional leads) such that they may be automatically handled. Automatic handling includes insertion, preforming and other operations. The emphasis of
13、 this standard is on the requirements for high-speed automatic insertion. This standard covers the lead taping requirements for components having two or more radial configured leads, provided these components may be taped in accordance with the requirements of this document. 2. NORMATIVE REFERENCES
14、The following standards contain provisions which, through reference in this Standard, constitute provisions of this Standard. All normative documents are subject to revision. 2.1 ANSI/ESD S541-2003 “Packaging Materials for ESD Sensitive Items“ 2.2 ANSI/ESD S20.20-2007 “Protection of Electrical and E
15、lectronic Parts, Assemblies and Equipment” 2.3 IPC/JEDEC J-STD-020C “Moisture/Reflow Sensitivity Classification for Nonhermetic Solid State Surface Mount Devices” 2.4 IPC J-STD-033B “Handling, Packing, Shipping and Use of Moisture/Reflow Sensitive Surface Mount Devices” 2.5 BS EN ISO 14001:2004 Envi
16、ronmental Management 3. DIMENSIONS 3.1 The coordinate system common to tapes and taped components with radial configured leads shall be used. The abscissa is a straight line through the centers of the sprocket holes. The ordinate is a line perpendicular to the abscissa through the center of the spro
17、cket hole that follows the component to be checked. All dimensions referencing the component leads are to the centerline of the lead. EIA-468-C Page 2 EIA-468-C Page 3 Table 1: Lead Taping Dimensions (See Figures 2 and 3) SYMBOL DESCRIPTION DIMENSIONS (mm) REFERENCE A Component Body Height 23 maximu
18、m Requirement 4.3 D0Sprocket Hole Diameter 4.00.2 d0Lead diameter 0.36 minimum 0.86 maximum Requirements 4.4 and 4.5 d1Lead width (non-circular leads) 0.35 minimum 0.75 maximum Requirement 4.5 d2Lead thickness (non-circular leads) 0.35 minimum 0.75 maximum Requirement 4.5 d3Lead diagonal (non-circul
19、ar leads) 0.85 maximum Requirement 4.5 F 2 Leaded Component Lead Spacing See Table 2, +0.6, -0.2 F1, F23 Leaded Component Lead Spacing 2.50 +0.4, -0.1 or 2.54 +0.4, -0.1 Requirement 4.6 F3Minimum inner spacing between leads F= 2.5 1.65 minimum F= 5.0 4.19 minimum F= 7.5 6.73 minimum F4Maximum outer
20、spacing of leads F= 2.5 3.68 maximum F= 5.0 6.22 maximum F= 7.5 8.76 maximum H Height to Seating Plane (Straight Leads) 18-20 Requirement 4.8 H0Height to Seating Plane (Formed Leads) 16.00.5 Requirement 4.7 H1Overall Height Above Abscissa 38.5 maximum Requirement 4.3 h Front-to-Back Deviation 1.0 ma
21、ximum Requirement 4.9 L Cut Out Length 11 maximum L1Lead Protrusion 1.0 maximum P Component Pitch (Nominal Dimension) See Table 2 P0Sprocket Hole Pitch 12.70.3 or 15.00.3 Requirement 4.10 P1Ordinate to Adjacent Component Lead See Table 2, 0.7 Requirement 4.6 and Figure 3 P2Ordinate to Component Cent
22、er Lead (3 Leaded Components) P0= 12.7 6.350.7 Fig. 3, Table 2 and Requirement 4.6 P0= 15.0 7.50.7 P3Lead Deviation in Carrier Tape 1.0 maximum Requirement 4.21 p Side-to-Side Deviation 1.3 maximum Requirement 4.9 t Composite Tape Thickness 0.9 maximum Requirement 4.11 t1Overall Tape and Lead Thickn
23、ess 2.0 maximum Requirement 4.11 W Carrier Tape Width 18 +1, -0.5 Requirements 4.12 and 4.13 W0Hold Down Tape Width 5 minimum Requirements 4.12 and 4.13 W1Sprocket Hole Position 9 +0.75, -0.5 W2Adhesive Tape Position 3 maximum Requirement 4.12 EIA-468-C Page 4 3.2 Component Pitch: The component pitc
24、h P depends on the pitch of the sprocket holes P0and the size of the component body, B. The positioning of the components shall be symmetrical in relation to the sprocket holes on the tape. Table 2: Component Pitch Nominal Dimensions (See Table 1) HOLE PITCH P0COMPONENT PITCH P FIG. LEAD SPACING F (
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECAEIA468C2008LEADTAPINGOFCOMPONENTSINTHERADIALCONFIGURATIONFORAUTOMATICHANDLINGPDF

链接地址:http://www.mydoc123.com/p-704372.html