ECA EIA-364-69A-2002 TP-69A Low Level Induction Measurement for Electrical Contacts of Electrical Connectors《TP-69A 电连接器的电触点的低水平感应测量》.pdf
《ECA EIA-364-69A-2002 TP-69A Low Level Induction Measurement for Electrical Contacts of Electrical Connectors《TP-69A 电连接器的电触点的低水平感应测量》.pdf》由会员分享,可在线阅读,更多相关《ECA EIA-364-69A-2002 TP-69A Low Level Induction Measurement for Electrical Contacts of Electrical Connectors《TP-69A 电连接器的电触点的低水平感应测量》.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、 EIA STANDARD TP-69A Low Level Induction Measurement for Electrical Contacts of Electrical Connectors EIA-364-69A (Revision of EIA-364-69) March 2002 ANSI/EIA-364-69A-2002(R2015) Approved: March 6, 2002 Reaffirmed: March 27, 2015 EIA-364-69ANOTICE EIA Engineering Standards and Publications are desig
2、ned to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of
3、 such Standards and Publications shall not in any respect preclude any member or nonmember of ECIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than ECI
4、A members, whether the standard is to be used either domestically or internationally. Standards and Publications are adopted by ECIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, ECIA does not assume any liability to any patent owner, nor does it
5、assume any obligation whatever to parties adopting the Standard or Publication. This EIA standard is considered to have International Standardization implication, but the International Electrotechnical Commission activity has not progresses to the point where a valid comparison between the EIA Stand
6、ard and the IEC document can be made. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the appli
7、cability of regulatory limitations before its use. (From Standards Proposal No. 4830, formulated under the cognizance of the CE-2.0 Committee on EIA National Connector and Socket Standards, and reaffirmed per Standards Proposal No. 5346.05). Published by Electronic Components Industry Association 20
8、15 Standards resolution: 0.1 nH; test frequency range: appropriate for the value of inductance being measured. See figure 1 for recommended test frequency plot. test frequency accuracy: 0.1%. EIA-364-69A Page 2 Figure 1 - Recommended test frequency range plot as a function of specimen inductance NOT
9、E Check the equipment manufacturers application notes or operating manuals for information regarding the minimum reactance required in the test specimen to optimize measurement accuracy at the desired measurement frequency(s). 2.2 Fixture The test fixture shall be a mechanically stable assembly. The
10、 spacing between test points should be adjustable to accept the specimen without the use of additional conductors. In general, the conductors of the test fixture should be perpendicular to the test sample as shown in figure A.1. NOTES 1 One-piece connectors require the use of a special fixture to al
11、low connection to the measuring equipment. This fixture shall have a known inductance if it cannot be zeroed out with the reference rod. 2 It is recommended that the fixtures provided by the equipment manufacturer be used as they typically improve measurement accuracy. Recommendedmeasurement areaEIA
12、-364-69A Page 3 3 Test specimen 3.1 Description The test specimen shall consist of one of the following: an individual contact; a mated contact assembly that would normally be installed in a connector; one-piece connectors (e.g. card edge connectors or chip sockets); mated two-piece connectors. 4 Te
13、st procedure Unless otherwise specified in the referencing document, the test frequency(s) should be in the recommended area shown in figure 1. The plot identifies the minimum frequency to ensure the minimum 5 ohms inductive reactance required to minimize measurement error using typical 50 ohm measu
14、rement equipment. The test professional should be aware of the limitations and associated accuracy levels when measuring values below 20 nanohenrys. Place the specimen a minimum of 5 cm from any objects that would affect measured results. 4.1 The inductance of at least three specimens shall be measu
15、red unless otherwise specified in the referencing document. In the case of multi-contact connectors, at least three specimens of each type of contact from at least three connector specimens shall be measured unless otherwise specified in the referencing document. For pin and socket contacts the dept
16、h of engagement shall be the nominally designed engagement depth unless specified in the referencing document. 4.2 The point of measurement shall be between the termination points of the specimen as shown in figure A.1. 4.3 Adjust the spacing of the test fixture test points to accept the specimen. 4
17、.4 Remove the specimen from the fixture, and in its place insert a round rod of known diameter having a length equal to that of the test sample. The rod diameter should be chosen to yield a calculated value slightly lower than that expected for the specimen. 4.4.1 The reference rod shall remain stra
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECAEIA36469A2002TP69ALOWLEVELINDUCTIONMEASUREMENTFORELECTRICALCONTACTSOFELECTRICALCONNECTORSTP69A 连接器

链接地址:http://www.mydoc123.com/p-704304.html