1、 EIA STANDARD TP-56E Resistance to Soldering Heat Test Procedure for Electrical Connectors and Sockets EIA-364-56E (Revision of EIA-364-56D) November 2011 Electronic Components Industry Association EIA-364-56E ANSI/EIA-364-56E-2011 (R2017) Approved: November 15, 2011 Reaffirmed: February 10, 2017 NO
2、TICE EIA Engineering Standards and Publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay
3、 the proper product for his particular need. Existence of such Specifications and Publications shall not in any respect preclude any member or nonmember of ECIA from manufacturing or selling products not conforming to such Specifications and Publications, nor shall the existence of such Specificatio
4、ns and Publications preclude their voluntary use by those other than ECIA members, whether the Specification is to be used either domestically or internationally. Specifications and Publications are adopted by ECIA in accordance with the American National Standards Institute (ANSI) patent policy. By
5、 such action, ECIA does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the Specification or Publication. This EIA Specification is considered to have International Standardization implications, but the International Electrotechnical Commi
6、ssion activity has not progressed to the point where a valid comparison between the EIA Specification and the IEC document can be made. This Specification does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of th
7、e user of this Specification to establish appropriate safety and health practices and to determine the applicability of regulatory limitations before its use. (From Standards Proposal No. 5382.05, formulated under the cognizance of the CE-2.0 Committee on EIA National Connector and Sockets Standards
8、) Published by Electronic Components Industry Association 2017 EIA Standards or Procedure 6, convection reflow . 6 5 Details to be specified . 8 6 Test documentation . 8 Table 1 Test conditions 6 2 Test levels . 7 Annex A Normative . A-1 (This page left blank) EIA-364-56E Page 1 TEST PROCEDURE No. 5
9、6E RESISTANCE TO SOLDERING HEAT TEST PROCEDURE FOR ELECTRICAL CONNECTORS AND SOCKETS (From EIA Standards Proposal No. 5220, formulated under the cognizance ECIA CE-2.0 Committee on National Connector Standards, and previously published in EIA-364-56D.) 1 Introduction 1.1 Scope This standard establis
10、hes a test method for determining if connectors or sockets can withstand exposure to soldering conditions either by soldering iron, solder dip, solder wave, or reflow soldering techniques. 1.2 Object Soldering conditions may affect the electrical characteristics of the connector or socket and/or cau
11、se damage to component materials. They may also result in loosening of terminations, softening or distortion of insulation materials, opening of solder seals, weakening of mechanical joints, etc. 1.3 Reference documents The following documents form a part of this standard to the extent indicated her
12、ein. In the event of conflict between this standard and the referenced document this standard shall take precedence. ANSI/EIA/IPC J-STD-004: Requirements for Soldering Fluxes ANSI/EIA/IPC J-STD-006: Requirements for Electronic Grade Solder Alloys and Fluxed and Non-Fluxed Solid Solders for Electroni
13、c Soldering Applications IPC-CH-65: Guidelines for Cleaning Printed Circuit Boards and Assemblies IPC/JEDEC J-STD-020: Moisture/Reflow Sensitivity Classification for Non-hermetic Solid State Surface Mount Devices EIA-364-56E Page 2 2 Test resources 2.1 Equipment 2.1.1 Solder pot A solder pot of suff
14、icient size to accommodate a mounting board (see 2.1.3) and of sufficient depth so that connector or socket terminations do not touch the bottom of the pot shall be used. This apparatus shall be capable of maintaining the solder at the specified temperature. The temperature shall be measured in the
15、center of the pot at a depth of at least 12.70 millimeters (0.500 inch), but no deeper than 25.4 millimeters (1.00 inch) below the surface of the solder. 2.1.2 Heat sinks or shielding The use of heat sinks or shielding is prohibited except when it is part of the connector or socket. When applicable,
16、 heat sinks or shielding shall be specified in the referencing document along with details such as materials of construction, part dimensions, method of attachment, and location of the necessary protection. 2.1.3 Mounting board 2.1.3.1 A mounting board suitable for the specified test temperature may
17、 be used. When applicable, the through-hole size shall be such that the diametrical clearance between it and the component terminals shall not exceed 0.71 millimeter (0.028 inch) nor be less than 0.15 millimeter (0.0006 inch), unless otherwise specified in the referencing document. For Procedure 3,
18、the board shall have no circuitry or copper surfaces. For Procedures 5 and 6, through-holes may be plated through. 2.1.3.2 The mounting board shall be of appropriate size so that it protrudes 19.05 millimeters (0.750 inch) minimum around the periphery of the connector or socket. For Procedure 3, its
19、 thickness shall allow the component terminals to protrude at least 0.762 millimeter (0.030 inch). 2.1.4 Reflow chambers The reflow chambers or equivalent equipment shall be of sufficient size to accommodate the mounting board or substrate containing the connector or socket to be evaluated. They sha
20、ll be capable of generating the specified temperature and environment. 2.1.5 Pre-heat equipment A suitable air circulating chamber shall be used that will maintain the temperature of the connector or socket within the tolerance and for the duration specified. EIA-364-56E Page 3 2.2 Material 2.2.1 So
21、lder The solder alloy shall conform to EIA/IPC J-STD-006, unless otherwise specified in the referencing document. In any case, it shall be suitable to attain the specified solder temperature. 2.2.2 Flux When applicable, the flux shall conform to either a no clean, a mildly activated, a highly activa
22、ted, or a corrosive (pH 1-2) type as found in EIA/IPC J-STD-004. If not specified in the referencing document a mildly activated type ROM0 (previously RMA) shall be used. In any case, it shall be suitable to insure solder wicking on the connector or socket terminations. 3 Test specimen 3.1 Descripti
23、on The test specimens shall be selected from an actual lot of production connectors or sockets per the referencing document. 3.2 Preparation 3.2.1 All test specimens shall be tested in their normal condition for assembly soldering. 3.2.2 The test specimens shall not be touched by fingers or otherwis
24、e contaminated, nor shall their terminations be wiped, cleaned, scraped, or abraded. Special preparation of terminations, such as bending or re-orienting before testing, shall be specified in the referencing document. 4 Test procedure Testing shall be performed with solder terminations attached to t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECAEIA36456E2011TP56ERESISTANCETOSOLDERINGHEATTESTPROCEDUREFORELECTRICALCONNECTORSANDSOCKETSPDF

链接地址:http://www.mydoc123.com/p-704286.html