《ECA EIA-364-17C-2011 TP-17C Temperature Life With or Without Electrical Load Test Procedure for Electrical Connectors and Sockets.pdf》由会员分享,可在线阅读,更多相关《ECA EIA-364-17C-2011 TP-17C Temperature Life With or Without Electrical Load Test Procedure for Electrical Connectors and Sockets.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、 EIA STANDARD TP-17C Temperature Life With or Without Electrical Load Test Procedure for Electrical Connectors and Sockets EIA-364-17C (Revision of EIA-364-17B) November 2011 Electronic Components Industry Association EIA-364-17C ANSI/EIA-364-17C-2011 (R2017) Approved: August 11, 2011 Reaffirmed: Fe
2、bruary 10, 2017 NOTICE EIA Engineering Standards and Publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining
3、with minimum delay the proper product for his particular need. Existence of such Specifications and Publications shall not in any respect preclude any member or nonmember of ECIA from manufacturing or selling products not conforming to such Specifications and Publications, nor shall the existence of
4、 such Specifications and Publications preclude their voluntary use by those other than ECIA members, whether the Specification is to be used either domestically or internationally. Specifications and Publications are adopted by ECIA in accordance with the American National Standards Institute (ANSI)
5、 patent policy. By such action, ECIA does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the Specification or Publication. This EIA Specification is considered to have International Standardization implications, but the International Elec
6、trotechnical Commission activity has not progressed to the point where a valid comparison between the EIA Specification and the IEC document can be made. This Specification does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the re
7、sponsibility of the user of this Specification to establish appropriate safety and health practices and to determine the applicability of regulatory limitations before its use. (From Standards Proposal No. 5382.02, formulated under the cognizance of the CE-2.0 Committee on EIA National Connector and
8、 Sockets Standards) Published by Electronic Components Industry Association 2017 EIA Standards & Technology Department 2214 Rock Hill Road, Suite 265 Herndon, VA 20170 PLEASE ! DONT VIOLATE THE LAW! This document is copyrighted by the ECIA and may not be reproduced without permission. Organizations
9、may obtain permission to reproduce a limited number of copies through entering into a license agreement. For information, contact: IHS 15 Inverness Way East Englewood, CO 80112-5704 or call USA and Canada (1-800-854-7179), International (303-397-7956) i CONTENTS Clause Page 1 Introduction . 1 1.1 Sc
10、ope . 1 1.2 Atmospheric pressure 1 2 Test resources 1 2.1 Equipment . 1 3 Test specimen 2 3.1 Description 2 3.2 Preparation 2 4 Test procedure . 2 4.1 Method A, without electrical load 2 4.2 Method B, with electrical load for connectors (superseded by method C) . 3 4.3 Method C, with electrical load
11、 3 4.4 Examination 4 5 Details to be specified . 4 6 Test documentation . 5 Table 1 Test chamber temperature without electrical load 2 2 Test time condition (duration) 3 ii (This page left blank) EIA-364-17C Page 1 TEST PROCEDURE No. 17C TEMPERATURE LIFE WITH OR WITHOUT ELECTRICAL LOAD TEST PROCEDUR
12、E FOR ELECTRICAL CONNECTORS AND SOCKETS (From EIA Standards Proposal No. 5156, formulated under the cognizance EIA CE-2.0 Committee on National Connector Standards, and previously published in EIA 364-17B.) 1 Introduction 1.1 Scope This standard establishes a test method to determine the ability of
13、an electrical connector and sockets to withstand elevated temperatures with or without electrical loading. 1.2 Atmospheric pressure This procedure for elevated temperature is performed at ambient (sea level) pressure. High altitude and space vacuum applications may require testing at reduced pressur
14、e as required by the referencing document. 2 Test resources 2.1 Equipment 2.1.1 Test Chamber (Applicable to all methods). A suitable air circulating chamber and equipment shall be used that will maintain, monitor and record the test temperature to the tolerance and for the duration specified in the
15、referencing document. The chamber size or capacity shall be such that the specimen under test shall be capable of dissipating the internally generated (I2R) specimen heat. 2.1.2 Current source (Applicable to Method C only) 2.1.3 Temperature monitoring equipment (Applicable to Method C only) EIA-364-
16、17C Page 2 3 Test specimen 3.1 Description The specimen shall consist of a fully assembled, mated with the specified number of contacts. Proper wire type, size, and preparation, sealing plugs, other hardware, and test boards shall be as specified in the referencing document. 3.2 Preparation 3.2.1 Un
17、less otherwise specified in the referencing document, the specimens, test boards, wires, and fixtures shall be normally positioned in the chamber so that there will be no restriction of the air flow. Unless otherwise specified in the referencing document, the specimens shall have the same size conta
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECAEIA36417C2011TP17CTEMPERATURELIFEWITHORWITHOUTELECTRICALLOADTESTPROCEDUREFORELECTRICALCONNECTORSANDSOCKETSPDF

链接地址:http://www.mydoc123.com/p-704233.html