1、 EIA STANDARD TP-11C Resistance to Solvents Test Procedure for Electrical Connectors and Sockets EIA-364-11C (Revision of EIA-364-11B) May 2014 EIA-364-11C ANSI/EIA-364-11C Approved: May 29, 2014 NOTICE EIA Engineering Standards and Publications are designed to serve the public interest through elim
2、inating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standards and Publications shall not in
3、 any respect preclude any member or nonmember of ECIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than ECIA members, whether the standard is to be used
4、 either domestically or internationally. Standards and Publications are adopted by ECIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, ECIA does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties ado
5、pting the Standard or Publication. This EIA Standard is considered to have International Standardization implication, but the International Electrotechnical Commission activity has not progressed to the point where a valid comparison between the EIA Standard and the IEC document can be made. This St
6、andard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations before its
7、 use. (From Standards Proposal No. 5324, formulated under the cognizance of the CE-2.0 Committee on EIA National Connector and Sockets Standards.) Published by Electronic Components Industry Association 2014 EIA Standards & Technology Department 2214 Rock Hill Road, Suite 265 Herndon, VA 20170 PLEAS
8、E ! DONT VIOLATE THE LAW! This document is copyrighted by the ECIA and may not be reproduced without permission. Organizations may obtain permission to reproduce a limited number of copies through entering into a license agreement. For information, contact: IHS 15 Inverness Way East Englewood, CO 80
9、112-5704 or call USA and Canada (1-877-413-5186), International (303-397-7956) i CONTENTS Clause Page 1 Introduction . 1 1.1 Scope . 1 2 Test resources 1 2.1 Equipment . 1 2.2 Material . 1 3 Test specimen 3 3.1 Description 3 4 Test procedure . 3 5 Details to be specified . 4 6 Test documentation . 4
10、 Table 1 Solvents . 2 ii (This page left blank) EIA-364-11C Page 1 TEST PROCEDURE No. 11C RESISTANCE TO SOLVENTS TEST PROCEDURE FOR ELECTRICAL CONNECTORS AND SOCKETS (From EIA Standards Proposal No. 5324 formulated under the cognizance EIA CE-2.0 Committee on National Connector Standards, and previo
11、usly published in EIA-364-11B.) 1 Introduction 1.1 Scope This procedure is to determine the ability of connector materials to withstand solvents that may be used to clean components. NOTE The test solutions indicated herein shall be considered as test mediums only. They shall not be considered as an
12、 indication, approval, recommendation or acknowledgment of industry usage. 2 Test Resources 2.1 Equipment 2.1.1 Beaker, container or vapor degreaser made of non-reactive material and of sufficient size 2.1.2 Wire mesh basket of sufficient size, if applicable 2.1.3 Weight scale accurate to within 1 g
13、ram 2.2 Material 2.2.1 One of the two groups of solvents as shown in table 1 shall be chosen to perform the test, contingent on the cleaning process involved. Test specimens shall be exposed to group 1 solvents, unless otherwise specified in the referencing document. 2.2.2 In the event solutions oth
14、er than those specified in table 1, are to be used, those solutions shall be specified in the referencing document along with the time and temperature levels involved. EIA-364-11C Page 2 CAUTION The solvents in table 1 exhibit some potential for health and safety hazards. The following safety precau
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECAEIA36411C2014TP11CRESISTANCETOSOLVENTSTESTPROCEDUREFORELECTRICALCONNECTORSANDSOCKETSPDF

链接地址:http://www.mydoc123.com/p-704225.html