1、APPROVED: October 28, 1988 EIA STANDARD Metallized Film Dielectric Capacitors for Alternating Current Application EIA-456-A JANUARY 1989 ELECTRONIC INDUSTRIES ASSOCIATION ENGINEERING DEPARTMENT EIA 456-A 89 M 3234b00 0070325 7 M NOTICE EIA Engineering Standards and Publications are designed to serve
2、 the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standa
3、rds and Publications shall not in any respect preclude any member or non-member of EIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than EIA members, wh
4、ether the standard is to be used either domestically or internationally. Recommended Standards and Publications are adopted by EIA without regard to whether or not their adoption may involve patents on articles, materials, or processes. By such action, EIA does not assume any liability to any patent
5、 owner, nor does it assume any obligation whatever to parties adopting the Recommended Standard or Publication. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to es
6、tablish appropriate safety and health practices and to determine the applicability of regulatory limitations before its use. O (From Standards Proposal No. 1913, formulated under the cognizance of the EIA P-2.6 Subcommittee on A.C. Capacitors.) Copyright 1989 Published by ELECTRONIC INDUSTRIES ASSOC
7、IATION Engineering Department 1722 Eye Street, N.W. Washington, D.C. 20006 All rights reserved Price: $19.00 Printed in U.S.A. . EIA 45b-A 89 W 3234b00 0070126 9 W EIA- 4 56 -A FIXED METALLIZED FILM DIELECTRIC CAPACITORS FOR ALTERNATING CURRENT APPLICATIONS TABLE OF CONTENTS REFERENCE Page Scope . P
8、aragraph 1 1 Definitions Paragraph 2 . 1 Standard Designations . i Paragraph 3 . 2 Applicable Documents Paragraph 4 . 5 Standard Test Conditions . Paragraph 5 . 5 Quality Assurance Visual and Mechanical Examination Marking Dielectric Withstanding Voltage e . Capacitance . DissipationFactor SealTest
9、. Vibration . Saltspray Paragraph 6 . . 5 Paragraph 7 . 7 Paragraph 8 . 7 Paragraph 9 . 7 Paragraph 10 . 8 Paragraph 11 . 8 Paragraph 12 . 8 Paragraph 13 . 8 Paragraph 14 . 8 Humidity . Paragraph 15 . 8 Solderability Paragraph 16 . 9 Terminal Strength . 1. . Paragraph 17 . 9 Protective Device . Para
10、graph 18 . 9 Leakage Current Test . Paragraph 19 . 9 Capacitance Change With Temperature High Room Temperature Life Test . Paragraph 20 . 9 Paragraph 21 . 9 i EIA 45b-A 89 m 3234600 0070327 O m J REFERENCE Room Temperature Life Test Paragraph 22 . 11 Appiication Notes . Paragraph .2 3. 11 Appendix A
11、 Explanation of Rating Tabulations . 13 Appendix B :; Summary of EN Standard . Designation . 14 Appendix C . Bushing and Terminal Details . 1517 to Appendix D. ; . Case ode from Nominal Black -6% to -3% White -3% to o Yellow o to t3% Red +3% to +6% 3.8 Design options are described in Paragraphs 3.8.
12、1 through 3.8.5. 3.8.1 3.8.2 3.8.3 3.8.4 Protective device shall be identified by the letter “P”. Capacitors containing the protective device shall be recognized by Underwriters Laboratories, or equivalent. 3.8.1.1 3.8.1.2 This protective device is intended to prevent case rupture and expulsion of i
13、nternal material when used within the current and voltage fault rating of this device. A minimum clearance above the capacitor terminais is required for effective opera- tion of the protective device. Manufacturer should be consulted for minimum recommended clearance after installation. Discharge re
14、sistor shall be identified by the letter “R” and shall discharge the capacitor to 50 volts or leas within one minute after disconnection of the capacitor from the voltage Ground lug shall be identified by the letter “G”. (See Appendix for ground lug details.) supply* ,- Leakage current to case, 3.8.
15、4.1 Low leakage current to case, required by UL1012 and UL1029, for some lighting and power 8upply applications shall be identified by the letter “K”. The leakage current value shall be determined by agreement between the supplier and the user. Low leakage current to case for motor application shall
16、 be identified by the . option letter “L”. When 115 volts 60 Hz is applied between the shorted capacitor terminale and the bare case the leakage current shail not exceed the following values: 3.8.4.2 EIA Li5b-A 89 323LibOO 0070332 4 EIA-456-A Page 5 Nominal Capacitance 0-14pF 14.1-2OpF 20.1 to 35pF
17、35.1 to 55pF O to 1OpF Voltage Rating 0-500 0-500 0-500 0-500 501 -660 Max. Leakage Micro Amperes 60 70 1 O0 150 1 O0 3.8.5 Room temperature life test - where a room temperature life test is required, it shall be identified by the letter “S”. The test is described in Paragraph 22. 4. APPLICABLE DOCU
18、MENTS The latest revisions of the following standards when specified form part of this document. (a) E.I.A. Standard RS-186, Standard Test Methods for Electronics Component Parts. (b) Bulletin E.I.A. Source Code and Date Code. (c) NEMA Standard Publication DC2-1970 Residential Controls (Quick-Connec
19、t Terminals). (d) U. L. Standards UL1012, Power Supplies, and UL1029, HID Lamp Ballasts. E.I.A. publications may be obtained from Electronic Industries Association, 2001 Eye Street, N.W., Washington, D.C. 20006. NEMA publications may be obtained from National Electrical Manufacturers Association, 21
20、01 L Street, Suite 300, Washington, D.C. 20037. U. L. Standards may be obtained from Underwriters Laboratories, Inc., Publications Department, 207 East Ohio Street, Chicago, Illinois 60611. 5. STANDARD TEST CONDITIONS 5.1 Standard atmospheric conditions under which tests are to be conducted or refer
21、red to shall be as shown below unless otherwise specified. Temperature: 20C to 35C (referred to 23C +2”C values) Barometric Pressure: 28 to 32 inches (94 to 110 kilopascals) Relative Humidity: Less than 80% 5.2 Standard test frequency is at 60 Hz. Measurements at other frequencies shall be referred
22、to 60 Hz. 6. QUALITY ASSURANCE 6.1 Recommended order of tests shall be as shown in Table 1. (See Page 7). No sample shall be sub- jected to more than one group of tests in Group 2, and Group 3 and Group 4. 6.2 Number of samples and allowable failures shall be as determined by agreement between the u
23、ser and the supplier. EIA 45b-A 89 W 3234600 0070333 b EIA- 4 5 6-A Page 6 TABLE 1 QUALITY ASSURANCE TEST PROGRAMS Requirements GROUP 1 (100% of Sample) Mechanical Inspection Paragraph 7 Marking Paragraph8 Dielectric Withstanding Voltage .-. . Paragraph 9 Capacltance Paragraph 10 Dissipation Factor
24、. Paragraph 11 Seal . Paragraph 12 Leakage Current to Case Paragraph 19 GROUP2 . (10% of Sample) Vibration Paragraph 13 Salt Spray (For Plated or Fainted Cases) . . .-. Paragraph 14 GROUP 3 (20% of Sample) Solderability (where required) Paragraph 16 Terminal Strength .Paragraph 17 Humidity Paragraph
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECA456A1989METALLIZEDFILMDIELECTRICCAPACITORSFORALTERNATINGCURRENTAPPLICATION 金属 薄膜 介质 交流 电容器 PDF

链接地址:http://www.mydoc123.com/p-704018.html