ECA 416-1974 Filters Radio Interference《无线电干扰滤波器》.pdf
《ECA 416-1974 Filters Radio Interference《无线电干扰滤波器》.pdf》由会员分享,可在线阅读,更多相关《ECA 416-1974 Filters Radio Interference《无线电干扰滤波器》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、EIA 4Lb 74 m 3234600 00b82bq T m / -3 AMERICAN NATIONAL STANDARD C83.102 - 1973 . Approved January 9, 1974 American National Standards Institute EIA STANDARD Filters, Rahbo Interference RS-416 March 1974 Engineering Department ELECTRONIC INDUSTRIES ., ASSOCIATION I EIA 41b 74 3234b00 00b8270 b NOTIC
2、E EIA engineering standards are desiged to serve the public interest through eliminating niis- understandings between manufacturers and purchasers, facilitating interchangeability and improve- ment of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper prod
3、uct for his particular need. Existence of such standards shall not in any respect pre- clude any member or non-member of EIA from manufacturing or selling products not conforming to such standards. Recommended standards are adopted by EIA without regard to whether or not their adoption may involve p
4、atents on articles, materials, or processes. By such action, EIA does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the recommended standards. Published by ELECTRONIC INDUSTRIES ASSOCIATION Engineering Department 2001 Eye Street, N,W., W
5、ashington, D. C. 20006 Electronic Industries Association 1974 .4ii rigliis rcscrwtl Price $1.50 Prinfed in U.S.A. EIA 416 74 m 3234600 0068271 8 m RS-416 Page 1 Filters, Radio Interference (From EI4 Standards Proposal No. 11 34-A, revision of Standards Proposal 11 34, formulated under the cognizance
6、 of EIA Working Group P-3.3 on Interference Filters). 1. SCOPE 1.1 This Standard covers the general requirements for current-carrying filters, alternating-current (ac) and direct-current (dc), for use primarily in the reduction of broadband radio interference. I 1.2 Portions of latest revisions of E
7、IA Standard RS-186 (Standard Test Methods for Passive Electronic Component Parts), and of MIL-STD-220 (Method of Insertion Loss Measurements), when specified, form a part of this Standard. a 2, STANDARD DESIGNATION . 2.1 The EIA Standard designation shall consist of six constituent parts as illustra
8、ted below: T Operating Class Style Current Insertion-Loss Terminal 2.1.1 2.1.2 Rating Characteristic Identification Temperature 2.1.3 2.1.4 2.1.5 Range 2.1.6 2.1.1 Class designation signifies the component is a Radio Interference Filter made to the requirements of EIA Standard RS-416. 2.1.2 Style is
9、 identified by the two-letter symbol “XX” followed by a two-digit number. The letters identify radio-interference filters; the digits identify the general shape, voltage rating, and mounting of the case. Each style designation may include a family of case sizes. 2.1.3 The current rating is identifie
10、d by a single letter in accordance with Table I. RC-416 . Page 2 EIA 4Lb 74 m 3234b00 00b272 T m Table 1 - Current Rating Symbol Rated Current A o. 1 B O. 3 C O. 5 D 1.0 E 1.5 F 2. o G 3.0 H 5. O J 7. O K 10.0 Symbol Rated Current L M N P R S T U v 20.0 30.0 55.0 70.0 100.0 150.0 200.0 300.0 500.0 2
11、.1.4 The insertion-loss characteristic is identified by.a single letter in accordance with Table II. Table II - Minimum Insertion-Loss Under Full Load Per MIL-STD-2ZOA Symbol Frequency in megahertz shown as column head and insertion-loss in column. 0.15 O. 3 0.6 1 10 20 100 1,000 dB A. 40. B. 50 C.
12、40 D. 45 E. 60 F. 8Q G. ., 20 dB 50 60 40 60 70 80 20 dB 60 60 40 80 80 80 20 dB 60 60 40 80 80 80 40 dB 60 60 40 80 80 80 40 dB dB 60 60 60 60 40 _ 80 70 80 80 80 80 40 40 w. For insertion-loss other than shown. dB 60 60 _ 70 -80 80 _ b . EIA 416 74 m 3234600 0068273 1 m RS-416 Page 3 2.1.5 Termina
13、ls are identified by a number in accordance with Table III. The number identifies the type of terminal. Table III - Terminal Types Number Type of Terminal 1 Solder lug 2 Radially tapped permanent stud 3 Threaded stud d 4 Lead wire 5 Connector 6 Other types 2.1.6 Operating temperature range is identi
14、fied by a single letter in accordance with Table IV. Table IV - Operating Temperature Range Symbol -20 to +?O IB -55 to +85 -55 to +lo5 -55 to +125 3, STANDARD TESTS 3.1 Standard Test Conditions 3.1.1 Unless otherwise specified, the atmospheric conditions at which tests are to be made or to which te
15、sts are to be referred, are as follows: Temperature. . . . . . . . . . . . . . . . . . . . . . . 25OC plus 10C minus SOC Barometric Pressure. . . , . . . . . . . . . . . . . 96.7 x 10 to 110.5 x 10 kg/m2 (27.95 to 31.93 in. of mercury) Relative Humidity. . . . . . . . . . . . . . . . . . Less than 8
16、0% 2 2 EIA 4Lb 74 I 3234600 0068274 3 9 . RS-416 Page 4 3.2 Testing Program 3.2.1 When required, recommended tests shall be made in the sequence iisted in Table V. Table V - Testing Program Group I Mechanical Inspection Marking Seal Test Dielectric- Withstanding- Voltage DC Resistance (dc units) Vol
17、tage Drpp (ac units) Insulation Resistance Insertion Loss Check Points Group II (AU Samples) 3.3.1 3.3.2 3.13 3.5 3.14.1 3.14.2 3.8 3.16.2 (1/3 of Samples) Insertion Loss 3.16.1 Overload 3.6 Temperature and Immersion Cycling 3.12 Leakage Current (when specified) 3.10 Mechanical Tests 3.4 Temperature
18、 Rise 3.7 , Group III (1/3 of Samples) Vibration 3.15 Moisture Resistance 3.9 Group IV (U3 of Samples) ,Higli-Ambient-Temperature Life 3.1 3.2.2 The number of samples and allowable failures shall be determined by agreement between the user and the supplier. 3.2.3 After Group 1 tests, no sample shall
19、 be subjected to tests of more than one group. 3.3 Mechanical Inspection 3.3.1 Dimensions must be within the tolerances allowed. 3.3.2 Marking shall be legible, complete and correct. EIA 4Lb 74 3234600 0068275 5 = RS-416 Page 5 3.4 Mechanical Tests 3.4.1 Full Test 3.4.1.1 Terminals shall withstand a
20、 steady pull of 2.00 kilograms (4.4 lbs.) applied axially for 10 seconds, per RS-186, Method 6, Type I. Terminal shall not fracture or break, nor shall there be any damage to the filter or seal. 3.4.2 Bending Test / 3.4.2.1. Filters with wire leads shall have a load of 1.00 kilogram (2.2 Ibs.) suspe
21、nded freely from each of its leads in turn, 2 (two) bends per RS-186, Method 6, Type III test. Two bends in opposite directions shall be applied. The leads shall not fracture or break, nor shall there be any damage to the filter or seal. 3.4.3 Ductility Test 3.4.3.1 Five complete turns of each wire
22、lead shall be Wou-nd qoun,d a cylinder haiing a diameter equal to the nominal diameter of the lead wire. The leads and lead coating shall not fracture or break. 3.4.4 Torsion Test 3.4.4.1 Threaded screw or stud terminals shall withstand without damage the torsion requirements of RS-186, Method 6, Ty
23、pe IV test. The following torque values shall be used: Screw Size 6-32 8-32 10-32 12-24 %-20 51 16- 24 3/8-24 7/16-20 1/2-28 1/2-20 Torque Meter-Kilograms .lo4 .161 .207 .265 .346 .576 1.15 1.73 2.30 2.88 (Lb. -inches) 9 14 18 23 30 50 100 150 200 250 3.5 Dielectric- Withstanding- Voltage Test 3.5.1
24、 Filters shall be tested in accordance with the applicable portions of EIA Standard RS-186, Method 4 for no less than one second and no. more than five seconds by applying between ter- minais and case a potential of 200% rated dc voltage or dc voltage equal to 2.828 times ac voltage unless otherwise
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ECA4161974FILTERSRADIOINTERFERENCE 无线电 干扰 滤波器 PDF

链接地址:http://www.mydoc123.com/p-704002.html