DOD MIL-STD-188-125-1-1998 HIGH-ALTITUDE ELECTROMAGNETIC PULSE (HEMP) PROTECTION FOR GROUND-BASED C41 FACILITIES PERFORMING CRITICAL TIME-URGENT MISSIONS PART 1 FIXED FACILITIES《基于.pdf
《DOD MIL-STD-188-125-1-1998 HIGH-ALTITUDE ELECTROMAGNETIC PULSE (HEMP) PROTECTION FOR GROUND-BASED C41 FACILITIES PERFORMING CRITICAL TIME-URGENT MISSIONS PART 1 FIXED FACILITIES《基于.pdf》由会员分享,可在线阅读,更多相关《DOD MIL-STD-188-125-1-1998 HIGH-ALTITUDE ELECTROMAGNETIC PULSE (HEMP) PROTECTION FOR GROUND-BASED C41 FACILITIES PERFORMING CRITICAL TIME-URGENT MISSIONS PART 1 FIXED FACILITIES《基于.pdf(107页珍藏版)》请在麦多课文档分享上搜索。
1、METRICMIL-STD-188-125-117 July 1998SUPERSEDINGMIL-STD-188-125A15 February 1994(3$570(17 2) ()(16(,17(5)$ distribution is unlimited.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-STD-188-125-1iiHIGH-ALTITUDE ELECTROMAGNETIC PULSE (HEMP) PROTECTIO
2、N FOR FIXED GROUND-BASED C I FACILITIES PERFORMING CRITICAL,4TIME-URGENT MISSIONSF O R E W O R D1. This military standard is approved for use by all Departments and Agencies of theDepartment of Defense (DoD). 2. Originally, Military Standard 188 (MIL-STD-188) covered technical standards for tactical
3、and long-haul communications, but later evolved through revisions (MIL-STD-188A, MIL-STD-188B) into a document applicable to tactical communications only (MIL-STD-188C).3. The Defense Information Systems Agency (DISA) published DISA circulars (DISAC)promulgating standards and engineering criteria ap
4、plicable to the long-haul DefenseCommunication System and to the technical support of the National Military CommandSystem.4. As a result of a Joint Chiefs of Staff action, standards for all military communications arenow being published in a MIL-STD-188 series of documents. The MIL-STD-188 series is
5、subdivided into a MIL-STD-188-100 series, covering common standards for tactical and long-haul communications; a MIL-STD-188-200 series, covering standards for tacticalcommunications only; and a MIL-STD-188-300 series, covering standards for long-haulcommunications only. Emphasis is being placed on
6、developing common standards for tacticaland long-haul communications published in the MIL-STD-188-100 series.5. This two-part document contains technical requirements and design objectives for high-altitude electromagnetic pulse (HEMP) protection of ground-based systems and facilities thatare nodes
7、in HEMP-hardened networks for performing critical and time-urgent command,control, communications, computer, and intelligence (C I) missions. This part 1 of the4document addresses HEMP hardening for fixed facilities; Part 2 addresses transportablesystems. The requirements are stringent, in order to
8、avoid both damage and functional upsetsthat prevent mission accomplishment within operationally prescribed timelines. The standardsapply uniformly to all systems and facilities in the end-to-end chain, since disruption of asingle node may result in network failure.6. Use of the standard for HEMP pro
9、tection of other fixed ground-based communications-electronics facilities that require HEMP hardening is encouraged to the extent permitted bycost constraints.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-STD-188-125-1iii7. Performance, accepta
10、nce test, and verification test requirements are contained in the bodyof the standard. HEMP-unique acceptance and verification test techniques are provided inAppendices A, B, and C.8. Implementation of MIL-STD-188-125-1 is supported by MIL-HDBK-423, “High-Altitude Electromagnetic Pulse (HEMP) Protec
11、tion for Fixed and Transportable Ground-BasedFacilities, Volume I: Fixed Facilities.“ The handbook also includes HEMP program planning,management, logistics, and data requirements for critical, time-urgent, fixed ground-basedfacilities.9. Beneficial comments (recommendations, additions, deletions) a
12、nd any pertinent datawhich may be of use in improving this document should be addressed to: Defense SpecialWeapons Agency/ESE, 6801 Telegraph Road, Alexandria, VA 22310-3398, by using theStandardization Document Improvement Proposal (DD Form 1426) appearing at the end ofthis document or by letter.Pr
13、ovided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-STD-188-125-1C O N T E N T SPARAGRAPH PAGEivFOREWORD ii 1. SCOPE . 1 1.1 Purpose . 1 1.2 Scope . 1 1.3 Applications 1 1.4 Objectives . 1 2. APPLICABLE DOCUMENTS 2 2.1 General . 2 2.2 Government docume
14、nts . 2 2.2.1 Specifications, standards, and handbooks 2 2.2.2 Other Government documents, drawings, and publications . 3 2.3 Non-Government publications 3 2.4 Order of precedence 4 3. DEFINITIONS . 5 3.1 Acronyms used in this standard . 5 3.2 Sources for definitions 7 3.3 Definitions . 8 3.3.1 Aper
15、ture point-of-entry (POE) 8 3.3.2 Conductive POE . 8 3.3.3 Continuous wave (CW) immersion . 8 3.3.4 Corrective maintenance . 8 3.3.5 Electromagnetic barrier . 8 3.3.6 Electromagnetic closure . 8 3.3.7 Electromagnetic stress 8 3.3.8 Facility HEMP shield . 8 3.3.9 HEMP acceptance test 9 3.3.10 HEMP ha
16、rdness . 9 3.3.11 HEMP hardness assurance 9 3.3.12 HEMP hardness configuration baseline . 9 3.3.13 HEMP hardness critical item (HCI) 9 3.3.14 HEMP hardness critical process (HCP) . 9 3.3.15 HEMP hardness maintenance (HM) 9 3.3.16 HEMP hardness maintenance and hardness surveillance (HM/HS) . 9 3.1.17
17、 HEMP protection subsystem 10 3.3.18 HEMP hardness surveillance (HS). . 10 3.3.19 HEMP hardness surveillance/reverification testing 10 3.3.20 Low-risk HEMP hardening . 10 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-STD-188-125-1C O N T E N T
18、SPARAGRAPH PAGEv3.3.21 Main barrier electrical POE protective device . 10 3.3.22 Mission-critical systems (MCS) 10 3.3.23 Norton equivalent circuit or Norton source 10 3.3.24 Penetrating conductor 10 3.3.25 Penetration entry area 11 3.3.26 Performance degradation . 11 3.3.27 Point-of-entry (POE) 11
19、3.3.28 POE protective device or POE treatment 11 3.3.29 Preventive maintenance . 11 3.3.30 Primary special electrical POE protective device 11 3.3.31 Protected volume 11 3.3.32 Pulsed current injection (PCI) 11 3.3.33 Residual internal stress 11 3.3.34 Retrofit HEMP hardening . 12 3.3.35 Secondary s
20、pecial electrical POE protective device 12 3.3.36 Shielded enclosure leak detection system (SELDS) 12 3.3.37 Special protective measures 12 3.3.38 Special protective volume . 12 3.3.39 Verification testing . 12 3.3.40 Vulnerability threshold (of an equipment) . 12 3.3.41 Waveguide below cutoff (WBC)
21、 12 3.3.42 Waveguide-below-cutoff array 13 4. GENERAL REQUIREMENTS 14 4.1 General . 14 4.1.1 HEMP protection overview 14 4.1.2 Integration with related requirements . 14 4.2 Hardness program overview 14 4.3 HEMP hardening design 15 4.3.1 Facility shield . 15 4.3.2 POEs . 15 4.3.3 MCS . 15 4.3.3.1 MC
22、S within the electromagnetic barrier. 15 4.3.3.2 MCS outside the electromagnetic barrier 15 4.3.3.3 HEMP-hardened electrical power 16 4.3.4 Special protective measures 16 4.4 HEMP testing . 16 4.4.1 Quality assurance program . 16 4.4.2 Acceptance testing . 16 4.4.3 Verification testing . 17 Provided
23、 by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-STD-188-125-1C O N T E N T SPARAGRAPH PAGEvi4.5 HM/HS . 17 4.5.1 HM/HS program development 17 4.5.2 HM/HS program implementation 17 5. DETAILED REQUIREMENTS . 18 5.1 HEMP protection subsystem topology 18 5.
24、1.1 Electromagnetic barrier topology 18 5.1.2 Penetration entry area . 18 5.2 Facility grounding . 18 5.2.1 Equipotential ground plane . 18 5.2.2 Grounding to the facility HEMP shield . 18 5.3 Facility HEMP shield . 19 5.3.1 Shielding effectiveness 19 5.3.2 Shield configuration 19 5.3.3 Shield monit
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DODMILSTD18812511998HIGHALTITUDEELECTROMAGNETICPULSEHEMPPROTECTIONFORGROUNDBASEDC41FACILITIESPERFORMINGCRITICALTIMEURGENTMISSIONSPART1FIXEDFACILITIES

链接地址:http://www.mydoc123.com/p-701847.html