DOD MIL-F-42024-1987 FORCEPS HEMOSTATIC CLIP (SMALL)《止血夹镊子(小的)》.pdf
《DOD MIL-F-42024-1987 FORCEPS HEMOSTATIC CLIP (SMALL)《止血夹镊子(小的)》.pdf》由会员分享,可在线阅读,更多相关《DOD MIL-F-42024-1987 FORCEPS HEMOSTATIC CLIP (SMALL)《止血夹镊子(小的)》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-F-42024 (DM) 26 February 1987 ATTN: Directorate of Medical Materiel, DPSC-RST, 2800 S. 20th Street, Philadelphia, PA 19101, by using self-addressed Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter. MILITARY SPECIFICATION FORCEPS, HEM
2、OSTATIC CLIP (Small) This specification is approved for use within the Defense- Personnel Support Center and is available for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers a small size hemostatic cli applying forceps for small hemosta
3、tic clips. -L 2 . APPLICABLE DOCUMENTS 2.1 Government documents. 2.1.1 Specifications and standards. The following specifications and standards form a part of this specification to the extent specified herein. Unless otherwise specified, the issues of these documents shall be those listed in the iss
4、ue of the Department of Defense Index of Specifications and Standards (DoDISS) and supplement thereto, cited in the solicitation. SPEC1 FI CATIONS FEDERAL THIS DOCUMENT CONTAINS / PAGES. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-F-42024 (DM
5、) MILTARY MIL-P- S. 16 - Preservation, Methods of. MIL-L-10547 - Liners, Case and Sheet, Overwrap; Water- Vaporproof or Waterproof, Flexible, STANDARDS MILITARY MfL-STD-LOS - Sampling Procedures and Tables for Inspection by Attributes. MIL-STD-129 - Marking for Shipment and Storage. MIL-STD-147 - Pa
6、lletized Unit Loads. MIL-STD-794 - Parts and Equipment, Procedures for Packaging of . 2.1.2 Drawing. The following drawing forms a part of this specification ta the extent specified herein. Unless otherwise specified, the issues shall be those in effect: on the date of the solicitation. DRAWING Defe
7、nse Personnel Support Center (DPSC) 23350 “ FORCEPS, HEMOSTATIC CLIP, Applying (Copies of specifications, standards, and drawing required by contractore in connection with specific acquisition functions should he obtained from the contracting activity or as directed by the contiacting activity.) 2,2
8、 Other publications. The following documents form a part of this specification to the extent specified herein. Unless otherwise specified, the issues of the documents which are DoD adopted shall be those listed in the issue of the DoBISS specified in the solicitation. Unless otherwise specified, the
9、 issues of documents not listed in the RoDXSS shall be the issue of the nongovernment documents which is current on the date of the solicitation. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-F-Ll202q 65 39933Ob 02b7433 b d MIL-F-42024 (DM) A
10、MERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) STANDARDS E ia - Rockwell Hardness and Rockwell Superficial Hardness of Metallic Materials, Tests for. E 92 - Vickers Hardness of Metallic Materials, Tests for. E 140 - Hardness Conversion Tables for Metals (Relationship Between Brinell Hardness, Vick
11、ers Hardness, Rockwell Hardness, Rockwell Superficial Hardness and Knoop Hardness). F 899 - Stainless Steel Billet, Bar and Wire for Surgical Instruments. F 921 - Standard Definition of Terms Relating to Hemostatic Forceps. (Application for copies should be addressed to the American Societ for Testi
12、ng and Materials, 1916 Race St., Philadelphia, PA 19103.) (Nongovernment standards and other publications are normally available from the organizations which prepare or which distribute th documents. These documents also may be available in or through libraries or other informational services. 2.3 O
13、rder of precedence. In the event of a conflict between the text of this specification and the references cited herein, the text of this specification shall take precedence. Nothing in this specification, however, shall supersede applicable laws and regulations unless a specific exemption has been ob
14、tained. 3 . REQUIREMENTS 3.1 General requirements. The forceps shall be in accordance wit the applicable requirements of GG-1-526 and as specified herein. It shall-be compatibe with small hemostatic clips.- Where referenced ir; this document, the term clip shall mean small hemostatic clip. 3 Provide
15、d by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.2 Style, desiqn and dimensions. The orceps shall be a ringed clip applying forceps suitable for holding and the application o small size hemostatic clips. The forceps shall be approximately 7-1/2 inches in l
16、ength with the distal clip holding jaw at a 15 degree angle to the handles. The handles shall be color coded to match the color coding of the hemostatic clips. The forceps shall be in strict accordance with DelEense Personnel Support Center (DPSC) Drawing 23350. The forceps shall have a spring betwe
17、en the handles so that the forceps are held in the Eully open position. The forceps shall contain a mechanism that limits the opening of the distal tip jaws to the maximum opening as shown on DPSC Drawing 23350. The tip of the jaws shall close first and the clip holding section shall be the only par
18、t o the jaws to close completely. 3.3 Material. The forceps shall be fabricate from Class 4, martensitic etainless steel in accordance with ASTM F899. 3.4 Hardness. Forceps shall have a Rockwell hardness o C40 to C47 when tested as specified in 4.4.1. The requirements of GG-1-526 tmii apply. 3.5 Pas
19、sivation. The forceps shall be properly passivated. 3.6 Clip retention. When tested as specified in 4.4.2, the clips shall not fall out of the jaws of the forceps when the forceps are held with jaws vertically downwmd. 3.7 Performance. When tested in accordance with 4.4.3, the orceps shall close the
20、 clips as specified. 3,8 Lucks. Shall be of box lock type. The box lock construction shall be accuEately fitted, and shall be without crevices, burrs, or sharp edges at any place in the lock construction. permanently secured. The joint performance shall be smooth, of equal resistance, and non-bindin
21、g in all positions when opening or closing the orceps (the lock may be lubricated). Further, under no circumstances shall looseness or free play of either shank permit any misalignment of the jaws in closing. NOTE: This paragraph shall replace the requirements specieied in GG-1-526 for locks. Pin or
22、 rivet shall 3.9 Finish. Finish shall be entirely mirror, satin or matte. Should the forceps be of mirror finish, the locks and ratchets shall be polished smooth, but need not possess a mirror finish. The matte einfeh shall exhibit a uniform non-directional surface texture equivalent to that produce
23、d by lightly blasting the prepared surface with Eine abrasives under pressure. 3,J.O Identification markinq. In addition to the requirements specified in GG-1-526, forceps o foreign manufacture shall be marked “etaSnless, 4 O E 4 a e Provided by IHSNot for ResaleNo reproduction or networking permitt
24、ed without license from IHS-,-,-MIL-F-42024 (DM) 3.11 Workmanship. The forceps shall be free from burrs, cracks, pits, sharp edges, scale, corrosion, or other defects which detract from its appearance or impair its serviceability. O 4. QUALITY ASSURANCE PROVISIONS 4.1 Responsibility for inspection.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。