1、MIL-C-3 7066 5 September 1974 MILITARY SPECIFICATION CASE, MEDICAL INSTRUMENT AND SUPPLY SET NYLON, NONRIGID, NO. 6 This specification is approved for use by all Departments and.Agencies of the Department of Defense. 1. SCOPE - 1.1 This specification covers an empty nylon case intended to hold instr
2、uments and supplies listed hereinafter,. and be suitable for use in minor surgical procedures in the field. 2. APPLICABLE DOCUMENTS 2.1 The following documents, of the issue in effect on the date of invitation for bids or request for proposals, form a part of this specification to the extent specifi
3、ed herein. .- SPECIFICATIONS Federal V-T-285 DDD-L-20 PPP-B- 5 6 6 PPP-B-5 85 PPP-By601 PPP-B- 6 21 PPP-B- 6 36 PPP-B-6 76 Military MIL-T-5038 MIL-F-21840 MIL-C-43128 Thread, Polyester Label; for Clothing, Equipage, and Tentage, (General Boxes , Foding, Paperbord Boxes, Wood, Wirebound Boxes , Cleat
4、ed-Plywood Boxes, Wood, Nailed and Lock-Corner Boxes, Shipping, Fiberboard Boxes, Setup Use) Tape, Textile and Webbing, Textile, Reinforcing, Nylon Fastener Tapes, Hook the sample size, the date of testing, the test method, individual test results, and the specification requirements. 4.2 Quality con
5、formance inspection. The examinations and tests required to assure conformance of those items or lots of items to be offered for acceptance are classified as specified in tables II and III (see 4.2.1 and 4.2.2) and 4.3, 4.2.1 Sampling for examination. Sampling for examination shall be conducted in a
6、ccordance with MIL-STD-105. The inspection levels and acceptable quality levels shall be as indicated in table II. purposes shall be one case, Unit of product For examination 5 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-C-370bb b5 m 77777Ob
7、0264375 3 m MIL-C- 3706 6 Table II. Sampliig for Visual Defects Inspection AQL (defects per level 100 units) Major II 2.5 Total (Major and Minor combined) II 6.5 4.2.2. Examination. The case shall be examined for defects including, but not limited to, those listed in table III, Table III. Classifica
8、tion of Defects Ma j or 101 102 103 10 4 105 106 107 108 109 110 111 112 Minor - 201 202 203 204 205 206 207 208 .209 6 Any component part missing. Any required operation omitted or improperly performed. Any hole, cut, tear, mend, patch or unauthorized splice. Needle chews that may develop into a ho
9、le. Any weakening defect such as smash, multiple float, or J.oose slub, that may develop into a hole. One or more spots or stains of an obviously permanent nature. Any seam twisted, puckered, affecting appearance or serviceability. Any open seam - 114 inch or more. Raw edges. - Tape fastener imprope
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DODMILC370661974CASEMEDICALINSTRUMENTANDSUPPLYSETNYLONNONRIGIDNO66 刚性 尼龙 医学 器械 供给 装置 容器 PDF

链接地址:http://www.mydoc123.com/p-701816.html