DOD MIL-A-89400-1995 U S AIR TARGET CHART - SERIES 200 (ATC-200)《U S AIR TAR美国空中目标图200系列》.pdf
《DOD MIL-A-89400-1995 U S AIR TARGET CHART - SERIES 200 (ATC-200)《U S AIR TAR美国空中目标图200系列》.pdf》由会员分享,可在线阅读,更多相关《DOD MIL-A-89400-1995 U S AIR TARGET CHART - SERIES 200 (ATC-200)《U S AIR TAR美国空中目标图200系列》.pdf(138页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-A-89400( DMA) - Superseding PSl4AAl380 January 1981 MILITARY SPECIFICATION U. S. AIR TARGET CHART - SERIES 200 (ATC-200) Thls specification is approved for use by the Defense Mapping Agency, and is available for use by ali Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scooe
2、. This general specification defines requirements for the Defense Mapping Agencys (DMA) U. S. Air Target Chart - Series 200 (ATC-200) which supports the radar/intelligence requirements of tactical and strategic air forces. 1.2 -. The purpose of this specification is to assure uniformity of treatment
3、 among mapping and charting elements, primarily DMA and its contractors, engaged in a coordinated production and maintenance program for this product. Feature requirements are stated in terms of DMAs Feature/Attribute Coding Standard (FACS), to maintain consistency between various DMA production met
4、hods. The use of FACS in this specification is not intended to imply any external digital data coding standard. FACS is the internal coding standard used by DMAs Digital Production System (DPS), which is the primary intended, but not exclusive, method for production of this product at this time. The
5、 Digital Geographic Information Exchange Standard (DIGEST) Feature Attribute Coding Catalog (FACC), not FACS, is the approved coding standard for the exchange of digital geographic data, as well as the standard for DMAs Vector Product Format (VPF) product line. FACC may be included in, or replace FA
6、CS in a future edition of this specification. 1.3 -. . This specification is 1.3.1 an .I s. UNCLAS S IF IED . . The security classification 1.3.2 Security classification of oroduct of the products generated by the use of these specifications will be the lowest category practicable. When it is necess
7、ary to assign a security classification to the product, it shall be in accordance with established national security procedures. Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving thls document should be addressed to: Director, Defense
8、 Mapping Agency, ATTN: PR, ST A-13, 8613 Lee Highway, Fairfax, VA 22031 -21 37 by using the Standardization Document Improvement Proposai (DD Form 1426) appearing at the end of this document or by letter. AMSC: NIA AREA: MCGT PISTRIBUTION STATF MENT 9. Approved for public release: Distribution unlim
9、ited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-A-89400 m 9999906 2030430 5T3 m MIL-A-89400 2. APPLICABLE DOCUMENTS 2.1 Government. . The following 2.1.1 SDeclfications. standards.00- specifications, standards, and handbooks form a part of
10、this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the current Department of Defense Index of Specifications and Standards (DODISS) and the supplement thereto, cited in the solicitation. (See 6.2) e. MILITARY STANDARDS: MIL-STD
11、-129 MIL-STD-2402 (DMA) MIL-STD-2403 (DMA) MIL-STD-2408 (DMA) MIL-STD-2409 MIL-STD-2410 (DMA) MIL-S TD-2 4 14 (DMA) - Marking for Shipment and Storage - MC Each 20,000 meter or yard grid line shall be shown across the face of the chart. (2) Additional ticks; Each 10,000 meter or yard unit shall be t
12、icked on the 20,000 meter or yard grid lines. The 10,000 meter or yard tick shall be centered on the 20,000 meter or yard grid. In addition, a 10,000 meter or yard cross tick shall be centered within each 20,000 meter or yard grid square. The lineweight of the cross tick shall be the same as other t
13、icks and the length (overall length) of each two ticks shall be 7.6 mm (0.3 inch). c. Ellipsoid, major grid and grid zone junctions shall be shown by a solid line extending from calibrated ruler type scale to bleeding edge across chart face. The identifying names of the ellipsoids or grids shall be
14、shown on each side of, and parallel with, the respective junction line. Example : NOTE: Exception is required when a junction line is coincident with a geographic limits of the chart. For those locations neither the junction line or the identifying names are to be shown. Respective data line(s) and
15、only label(s) which are pertinent to geographic interior of chart shall be shown in the grid reference box diagram. (See 3.10.1.2.f) BESSEL ELLIPSOID INTERNATIONAL ELLIPSOID UTM GRID ZONE DESIGNATION 37R MALAY GRID d. The grid square identification (100,000 unit squares) shall be shown at each 100,0
16、00 unit grid line intersection. When the system is a British Grid that identifies larger grid squares or areas e.g., 500,000 unit squares, in addition to then 100,000 unit squares, then the extra identification shall be shown in smaller letters (or letters and figures) immediately preceding the 100,
17、000 unit grid square identification. See APPENDIX B - ATC Style Sheet, for type size, style and position. e. Grid Labeling of each 100,000 and 10,000 unit tick shall be identified by a value placed opposite the tick. The value may, however, be moved slightly in order to avoid overprinting other info
18、rmation. When the chart includes more than one major grid ellipsoid or zone, then full grid tick values shall be shown at the first 100,000 or 10,000 unit grid tick in each direction from each corner of chart. (i) A grid zone junction may fall so near the edge of a chart that a 100,000 or 10,000 uni
19、t tick for one of the grid zones does not appear on the chart. In this case, the full value shall be shown for the 1,000 unit 9 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-A-89400 999990b 2030438 894 W MIL-A-89400 tick nearest the edge of the
20、 chart. In addition, full grid tick values shall be shown as specified in paragraph above. (2) When the chart includes only one major grid and the sequence of grid tick values is uniform, then a full grid tick value shall be placed on the first 100,000 or 10,000 unit grid tick in each direction from
21、 the Southwest corner only. (3) Full grid tick values shall include the abbreviated designation of the measuring unit “mug for meters (or tryds“) for yards on some British grids) and the abbreviated geographic designation of the tick, “N“ for Northings and “E“ for Eastings. . (4) Intermediate Tick V
22、alues shall show only the principal digits and digits preceding principal digits. A combination of two type sizes shall be used to show tick values, 6 pt. and 10 pt. Swiss 742. Exception shall be when three major grids appear on a graphic. When this condition occurs, 6 pt. and 10 pt. Swiss 742 light
23、 condensed type shall be used for grid tick values on one of the two grids which are more alike from the standpoint of similarity of values or declination of the grid ticks. (5) When additional labeling is required, the principal figure (one digit) for each 20,000 meter or yard grid value shall be p
24、ositioned to the north of the 10,000 meter or yard easting ticks and the northing values positioned to the east of the 10,000 meter or yard northing ticks. The grid lines shall be broken and the figures centered on the axis of the line. (6) See APPENDIX B - ATC Style Sheet for type style, size and p
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DODMILA894001995USAIRTARGETCHARTSERIES200ATC200USAIRTAR 美国 空中 目标 200 系列 PDF

链接地址:http://www.mydoc123.com/p-701812.html