1、A-A-54937 9999974 0162327 OLib 9 INCH-POUND A-A-5 4 9 3 7 25 January 1994 COMMERCIAL ITEM DESCRIPTION VACUUM CLEANER, PLASTER The General Services Administration has authorized the use of this Commercial Item Description. This Commercial Item Description covers a portable vacuum cleaner used to disp
2、ose of plaster dust during orthopedic procedures. Salient characteristics: The portable plaster vacuum cleaner, shall be 12 inches long x 11 inches high x 5 inches wide, suitable for use in collecting plaster dust during cast cutting/trimming orthopedic procedures. As an alternate, the vacuum cleane
3、r may be approximately 9 inches diameter by 23 inches high. The unit shall operate on 115/230 volt, 50- 60 Hz, AC. The vacuum cleaner shall be capable of generating a minimum of 46 inches of water operating with a motor drawing no more than 1.16 horsepower (865 watts). Materials and constructions. T
4、he vacuum cleaner shall have a high impact plastic casing with a handle integrated into the top of the casing. A minimum of 5 feet of 1-1/4 inch I.D. plastic tubing shall be distally attached to an opening on the front of the vacuum cleaner with a twist- lock mechanism. The opposite (proximal) end o
5、f the tubing shall have a metal male connecting piece that secures in place on the blade (distal) end of tne cast cutter. Input power-.- from the following line sources: 110 vclts, plus and miniis 10 percent, and 230 volts, plus and minus 10 percent alternating current, multiple frequency, 50 and 60
6、 Hz plus or minus 2 Hz. The cleaner shall be capable of operating AMSC N/A FSC 6515 DI-STRIBCTION STATEMENT A: distribution is unlimited. Approved for public release; Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A - A-5 4 9 3 7 H 9799974 OLb2328 T
7、82 H A-A- 5 4 9 3 7 Modifications to the offerors standard commercial item which will allow operation on all the above voltage levels and 50/60 Hz may be acceptable. The design modification may be integral to the equipment or may consist of a separate external eqUil;ment itcm(s). The conversion kit
8、shall include adequate instructions for the Government to perform the modifications. modifications requiring more than orie manhour to accomplish are not acceptable. Complex Metal parts shall be fabricated of a suitable corrosion- resisting steel, properly hardened and passivated. Material used in t
9、he fabrication of the vacuum cleaners shall be of the highest quality throughout and suitable in all respects for the intended use. The vacuum cleaner shall have an electric cable approximately 12 inches long attached to the lateral portion of the metal tube connection. This cable shall be equipped
10、with a female plug end that is compatible with the 3-prong hospital grade male plug end on the cast cutter electrical cable. The cleaner shall alsc be provided with a 5 to 6 foot power cable with proper provisions for plugging into 115 or 230 volts. Accessories. The vacuum cleaner shall be supplied
11、with a plastic or coated metal wall mounting bracket, a semi- disposable cloth plastic bag, and all other components necessary to perform its function. Compatability. The distal end of the vacuum cleaner hose shall have a male connecting piece specifically designed to attach to the blade housing of
12、an orthopedic cast cutting saw used to cut casts without patient injury. Note 1. See 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-54937 9999974 OLb2329 919 Identification markin% The following marking shall be furnished: a. Name or registere
13、d trademark of the manufacturer. b. Type or model number. c. Serial number. d. Electrical characteristics. e. National Stock Number (NSN). f. Federal Supply Code for Manufacturers (FSCM). g. Quarter and year of manufacture (3Q81 - designates third quarter of 1981). Nameplates shall be permanently an
14、d securely attached to the equipment. Adhesives shall not be used. Equipment shall be permanently and legibly marked in accordance with the general marking requirements of MIL-STD-130. The nameplate shall be located on an external equipment surface which is readily accessible. Interchanqeability, Pa
15、rts having the same manufacturers part number shall be fully and functionally interchangeable. All major components of the assembled system having the same model number shall be physically and functionally interchangeable. Enqineerinq desiqn chanqes. The contractor shall notify the provisioning acti
16、vity of all changes whether of a production or modification type which are approved for incorporation into the end item furnished under the contract and which modify, add to, delete, or supersede parts in the end item or its supporting equipment. O Safe& All items shall conform to the applicable req
17、uirements of a nationally recognized standard for the safety of medical equipment such as UL544 or equal of the issue in effect on the date of solicitation. All items shall be approved as conforming to such a standard by an nationally recognized testing laboratory. Service data. The contractor shall
18、 furnish, with each unit, two copies of service data containing complete instructions for assembly, operation, maintenance, and a list of component parts. All information contained in the manual shall be indexed so that the replacement parts can be ordered by the manufacturers part number, and witho
19、ut confusion as to the item identification. Identical or interchangeable replacement parts shall be identified by a single part number only. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-54937 = 9999974 0162330 630 A-A-5 4 93 7 - Reusable con
20、tainer. No reusable container is required. Workmanship2 Workmanship shall be first class throughout. Vacuum cleaners shall be free from defects which detract from their appearance or which may impair their serviceability. Unit. Each (EA). One vacuum cleaner, complete with all accessories and manuals
21、, as specified, constitutes one unit of issue. Qu a 1 it y As sur anc e P r ov-i s-o is2 Responsibility for inspection. Unless otherwise specified in the contract or purchase order, the contractor is responsible for the performance of all inspection requirements as specified herein. Except as otherw
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DODAA549371994VACUUMCLEANERPLASTER 石膏 真空 吸尘器 PDF

链接地址:http://www.mydoc123.com/p-701798.html