DOD A-A-53483-1988 STAPLER SURGICAL (GASTRO-INTESTINAL)《外科原材料(胃与肠的)》.pdf
《DOD A-A-53483-1988 STAPLER SURGICAL (GASTRO-INTESTINAL)《外科原材料(胃与肠的)》.pdf》由会员分享,可在线阅读,更多相关《DOD A-A-53483-1988 STAPLER SURGICAL (GASTRO-INTESTINAL)《外科原材料(胃与肠的)》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、A-A-53483 65 7777774 0030873 5 p-3)- 91 A-A-53 48 3 8 May 1988 COMMERCIAL ITEM DESCRIPTION STAPLER, SURGICAL (Gastro-intestinal) The General Services Administration has authorized the use of this commercial item description. This commercial item description covers a gastro-intestinal surgical staple
2、r. Salient characteristics: Style and design. Shall be a gastro-intestinal surgical stapler. The stapler shall consist of a cartridge half and an anvil half. Style and design of the cartridge half shall be in accordance with Figure 1. The cartridge half shall consist of a handle and channeled cartri
3、dge fork, Both components shall be attached by means of a distal pivot (see Figure 1). The handle shall have a proximal snap-anchor and transverse bar. The snap-anchor shall be designed to hold the cartridge fork in place until manually detached. The cartridge fork shall contain four alignment slots
4、; two on each side, identically spaced on both sides of the fork. This arrangement shall permit the fork to accept a compatible staple unit . Style and design of the anvil half shall be in accordance with Figure 2. The anvil half shall consist of an anvil fork and lock lever. The proximal end of the
5、 lock lever shall be joined to the mid-point of the anvil by means of the lock-lever pivot. The anvil fork shall have a distal engagement hook and a proximal anvil. The anvil shall contain 52 staple-clinching pockets arranged in two double-staggered rows. The pocket pattern shall match the staple- c
6、hannel pattern contained in the compatible staple unit. Performance. The stapler shall be capable of undergoing repeated assembly and disassembly cycles without jamming or breakage. When the user loads a compatible staple unit and follows the operating manual, the stapler shall place 52 surgical sta
7、ples, arranged in two duble-staggered rows, into tissue and split the tissue between the staples. AMSC N/A FSC 6515 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. THIS DOCUMENT CONTAINS PAGES. Provided by IHSNot for ResaleNo reproduction or networking permitted wit
8、hout license from IHS-,-,-A-A-53483 65 qqqqlq 0030874 ? e A-A-53 48 3 I Materials. The stapler shall be fabricated rom rigid plastic and corrosion-resisting steel, to ASTMDesignation F899. All materials shall be suitable for the purpose intended, Corrosion-resisting steel shall conform Instructions.
9、 The stapler shall be supplied with a “Directions for fEGPTKual . Workmanship. The stapler shall be free from defects that detract grorri fts appearance or impair its serviceability, - Unit. Each (EA). One stapler, as specified, constitutes one unit. Quality Assurance Provisions. Unless otherwise sp
10、ecified in the contract or purchase order, the contractor is responsible for the performance of all inspection requirements as specified herein, Except ar; otherwise specified in the contract or purchase order, the contractor may use hic own or any facilities suitable for the performance of the insp
11、ection requirements specified herein, unless disapproved by the Government. The Government reserves the right to perform any o the inspections set forth in the specification where such inspections are deemed necessary to assure supplies and services conrorm to prescribed requirements. Records o exam
12、inations and tests performed by or or the 6ontaactoT shall be maintained by the contractor and made available to the Government upon the Governments request, at any time, or from time to time, during the performance of the contract and or a period of three years after delivery of the supplies to whi
13、ch such records relate. Re8ponsibility or inspection. Recorde. Ins oction. Inspection, as used herein, is defined as both examination + such as visual or auditory investigation without the use o special laboratory appliances or procedures) and testing (determination by technical means o physical and
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DODAA534831988STAPLERSURGICALGASTROINTESTINAL 外科 原材料 PDF

链接地址:http://www.mydoc123.com/p-701674.html