DLA W-F-1814 1 C-2009 FUSE CARTRIDGE HIGH INTERRUPTING CAPACITY CLASS G (CURRENT-LIMITING) 600 VOLTS 0-15 AMPERES.pdf
《DLA W-F-1814 1 C-2009 FUSE CARTRIDGE HIGH INTERRUPTING CAPACITY CLASS G (CURRENT-LIMITING) 600 VOLTS 0-15 AMPERES.pdf》由会员分享,可在线阅读,更多相关《DLA W-F-1814 1 C-2009 FUSE CARTRIDGE HIGH INTERRUPTING CAPACITY CLASS G (CURRENT-LIMITING) 600 VOLTS 0-15 AMPERES.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、 AMSC N/A FSC 5920 W-F-1814/1C 21 July 2009 SUPERSEDING W-F-1814/1B 25 June 2004 FEDERAL SPECIFICATION SHEET FUSE, CARTRIDGE, HIGH INTERRUPTING CAPACITY, CLASS G (CURRENT-LIMITING) 600 VOLTS, 0-15 AMPERES The General Services Administration has authorized the use of this federal specification sheet
2、by all federal agencies. The complete requirements for procuring the fuses described herein shall consist of this document and the latest issue in effect of W-F-1814. Inches mm .006 .15 .03 .76 .281 7.14 .375 9.53 .406 10.31 1.31 33.27 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are gi
3、ven for general information only. 3. Minimum acceptable thickness of ferrule side wall .025 (.64 mm). 4. Unless otherwise specified, tolerances are .02 (0.51 mm) for two-place decimals and .005 (0.13 mm) for three-place decimals. FIGURE 1. Configuration and dimensions. INCH-POUND Provided by IHSNot
4、for ResaleNo reproduction or networking permitted without license from IHS-,-,-W-F-1814/1C 2 REQUIREMENTS: Interface and physical dimensions: See figure 1. Physical: Nonrenewable. Terminals: Ferrule type. Material: Brass, copper, or copper alloy. Strength: 2 pound-inches torque between body and ferr
5、ules. Body: Insulating material: Fiber, ceramic, melamine-impregnated glass fiber, or other suitable material. Electrical: Voltage: 600 volts or less. Frequency: 48 Hz to 60 Hz. Current: See table l. Current carrying capacity: 100 percent indefinitely with temperature rise not to exceed 75C above am
6、bient on the ferrules. Overload interrupt: Instantaneous: Shall interrupt within 1 hour at 135 percent of rated current and within 4 minutes at 200 percent of rated current. Time delay: In addition to the above requirement, the fuse shall not interrupt 200 percent of rated current within 12 seconds.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAWF18141C2009FUSECARTRIDGEHIGHINTERRUPTINGCAPACITYCLASSGCURRENTLIMITING600VOLTS015AMPERESPDF

链接地址:http://www.mydoc123.com/p-701564.html