DLA SMD-5962-99544 REV C-2010 MICROCIRCUIT HYBRID LINEAR 3 3 VOLT SINGLE CHANNEL DC DC CONVERTER.pdf
《DLA SMD-5962-99544 REV C-2010 MICROCIRCUIT HYBRID LINEAR 3 3 VOLT SINGLE CHANNEL DC DC CONVERTER.pdf》由会员分享,可在线阅读,更多相关《DLA SMD-5962-99544 REV C-2010 MICROCIRCUIT HYBRID LINEAR 3 3 VOLT SINGLE CHANNEL DC DC CONVERTER.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Table I, Efficiency test, change minimum limit for subgroup 1 from 76% to 74% and subgroup 2,3 from 75% to 74%. Update drawing boilerplate. 03-05-28 Raymond Monnin B Table I, VOUTload regulation test, subgroups 2 and 3 maximum limit, change 20 mV
2、 to 30 mV. 05-11-16 Raymond Monnin C Added footnote 1 to table II, under group C end-point electricals. Updated drawing paragraphs. -sld 10-11-10 Charles F. Saffle REV SHEET REV SHEET REV STATUS REV C C C C C C C C C C C C C C OF SHEETS SHEET 1 2 3 4 5 6 7 8 9 10 11 12 13 14 PMIC N/A PREPARED BY Gar
3、y Zahn DLA LAND AND MARITIME STANDARD MICROCIRCUIT DRAWING CHECKED BY Michael C. Jones COLUMBUS, OHIO 43218-3990 http:/www.dscc.dla.mil THIS DRAWING IS AVAILABLE FOR USE BY ALL DEPARTMENTS APPROVED BY Kendall A. Cottongim MICROCIRCUIT, HYBRID, LINEAR, 3.3 VOLT, SINGLE CHANNEL, DC/DC CONVERTER AND AG
4、ENCIES OF THE DEPARTMENT OF DEFENSE DRAWING APPROVAL DATE 99-05-18 AMSC N/A REVISION LEVEL C SIZE A CAGE CODE 67268 5962-99544 SHEET 1 OF 14 DSCC FORM 2233 APR 97 5962-E470-10Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWI
5、NG SIZE A 5962-99544 DLA LAND AND MARITIME COLUMBUS, OHIO 43219-3990 REVISION LEVEL C SHEET 2 DSCC FORM 2234 APR 97 1. SCOPE 1.1 Scope. This drawing documents five product assurance classes as defined in paragraph 1.2.3 and MIL-PRF-38534. A choice of case outlines and lead finishes which are availab
6、le and are reflected in the Part or Identifying Number (PIN). When available, a choice of radiation hardness assurance levels are reflected in the PIN. 1.2 PIN. The PIN shall be as shown in the following example: 5962 - 99544 01 H X A Federal RHA Device Device Case Lead stock class designator type c
7、lass outline finish designator (see 1.2.1) (see 1.2.2) designator (see 1.2.4) (see 1.2.5) / (see 1.2.3) / Drawing number 1.2.1 Radiation hardness assurance (RHA) designator. RHA marked devices shall meet the MIL-PRF-38534 specified RHA levels and shall be marked with the appropriate RHA designator.
8、A dash (-) indicates a non-RHA device. 1.2.2 Device type(s). The device type(s) identify the circuit function as follows: Device type Generic number Circuit function 01 MOR283R3S DC/DC converter, 66 W, +3.3 V output 1.2.3 Device class designator. This device class designator shall be a single letter
9、 identifying the product assurance level. All levels are defined by the requirements of MIL-PRF-38534 and require QML Certification as well as qualification (Class H, K, and E) or QML Listing (Class G and D). The product assurance levels are as follows: Device class Device performance documentation
10、K Highest reliability class available. This level is intended for use in space applications. H Standard military quality class level. This level is intended for use in applications where non-space high reliability devices are required. G Reduced testing version of the standard military quality class
11、. This level uses the Class H screening and In-Process Inspections with a possible limited temperature range, manufacturer specified incoming flow, and the manufacturer guarantees (but may not test) periodic and conformance inspections (Group A, B, C, and D). E Designates devices which are based upo
12、n one of the other classes (K, H, or G) with exception(s) taken to the requirements of that class. These exception(s) must be specified in the device acquisition document; therefore the acquisition document should be reviewed to ensure that the exception(s) taken will not adversely affect system per
13、formance. D Manufacturer specified quality class. Quality level is defined by the manufacturers internal, QML certified flow. This product may have a limited temperature range. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRA
14、WING SIZE A 5962-99544 DLA LAND AND MARITIME COLUMBUS, OHIO 43219-3990 REVISION LEVEL C SHEET 3 DSCC FORM 2234 APR 97 1.2.4 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows: Outline letter Descriptive designator Terminals Package style T See figure 1 12 Tabbed fl
15、ange mount, lead formed up U See figure 1 12 Flange mount, lead formed down X See figure 1 12 Flange mount, short lead Y See figure 1 12 Tabbed flange mount, short lead Z See figure 1 12 Tabbed flange mount, lead formed down 1.2.5 Lead finish. The lead finish shall be as specified in MIL-PRF-38534.
16、1.3 Absolute maximum ratings. 1/ Input voltage range (VIN) 2/ -0.5 V dc to +50 V dc Power dissipation (PD) . 27 W Lead temperature (10 seconds) +300C Storage temperature . -65C to +150C 1.4 Recommended operating conditions. Input voltage range (VIN) . +16 V dc to +40 V dc Output power . 66 W Case op
17、erating temperature range (TC) -55C to +125C 2. APPLICABLE DOCUMENTS 2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are
18、 those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATION MIL-PRF-38534 - Hybrid Microcircuits, General Specification for. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-883 - Test Method Standard Microcircuits. MIL-STD-1835 - Interface Standard for Electronic Component Case Outline
19、s. DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - List of Standard Microcircuit Drawings. MIL-HDBK-780 - Standard Microcircuit Drawings. (Copies of these documents are available online at https:/assist.daps.dla.mil/quicksearch/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Bui
20、lding 4D, Philadelphia, PA 19111-5094.) 2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exe
21、mption has been obtained. 1/ Stresses above the absolute maximum ratings may cause permanent damage to the device. Extended operation at the maximum levels may degrade performance and affect reliability. 2/ An undervoltage lockout circuit shuts the unit off when the input voltage drops to approximat
22、ely 14.5 volts. Operation of the unit between 14.5 volts and 16 volts is nondestructive, but performance is not guaranteed. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-99544 DLA LAND AND MARITIME COLUMBUS
23、, OHIO 43219-3990 REVISION LEVEL C SHEET 4 DSCC FORM 2234 APR 97 3. REQUIREMENTS 3.1 Item requirements. The individual item performance requirements for device classes D, E, G, H, and K shall be in accordance with MIL-PRF-38534. Compliance with MIL-PRF-38534 may include the performance of all tests
24、herein or as designated in the device manufacturers Quality Management (QM) plan or as designated for the applicable device class. The manufacturer may eliminate, modify or optimize the tests and inspections herein, however the performance requirements as defined in MIL-PRF-38534 shall be met for th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLASMD596299544REVC2010MICROCIRCUITHYBRIDLINEAR33VOLTSINGLECHANNELDCDCCONVERTERPDF

链接地址:http://www.mydoc123.com/p-701370.html