DLA SMD-5962-92054 REV C-2012 MICROCIRCUIT HYBRID LINEAR 90-VOLT SYNCHRO TO DIGITAL CONVERTER.pdf
《DLA SMD-5962-92054 REV C-2012 MICROCIRCUIT HYBRID LINEAR 90-VOLT SYNCHRO TO DIGITAL CONVERTER.pdf》由会员分享,可在线阅读,更多相关《DLA SMD-5962-92054 REV C-2012 MICROCIRCUIT HYBRID LINEAR 90-VOLT SYNCHRO TO DIGITAL CONVERTER.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Correct notes to tests in table I and figure 1. Update drawing requirements to MIL-PRF-38534. 01-06-14 Raymond Monnin B Rewrite paragraphs 4.2.a.2. and 4.3.3.b.2 to add TC. 04-06-18 Raymond Monnin C Updated drawing paragraphs. -sld 12-02-13 Charl
2、es F. Saffle REV SHEET REV SHEET REV STATUS REV C C C C C C C C C C C OF SHEETS SHEET 1 2 3 4 5 6 7 8 9 10 11 PMIC N/A PREPARED BY Steve L. Duncan DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 http:/www.landandmaritime.dla.mil/ STANDARD MICROCIRCUIT DRAWING CHECKED BY Michael C. Jones THIS DRAWING
3、 IS AVAILABLE FOR USE BY ALL DEPARTMENTS APPROVED BY Kendall A. Cottongim MICROCIRCUIT, HYBRID, LINEAR, 90-VOLT SYNCHRO TO DIGITAL CONVERTER AND AGENCIES OF THE DEPARTMENT OF DEFENSE DRAWING APPROVAL DATE 93-01-19 AMSC N/A REVISION LEVEL C SIZE A CAGE CODE 67268 5962-92054 SHEET 1 OF 11 DSCC FORM 22
4、33 APR 97 5962-E159-124 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-92054 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL C SHEET 2 DSCC FORM 2234 APR 97 1. SCOPE 1.1 Scope. This drawing do
5、cuments five product assurance classes as defined in paragraph 1.2.3 and MIL-PRF-38534. A choice of case outlines and lead finishes which are available and are reflected in the Part or Identifying Number (PIN). When available, a choice of radiation hardness assurance levels are reflected in the PIN.
6、 1.2 PIN. The PIN shall be as shown in the following example: 5962 - 92054 01 H X X Federal RHA Device Device Case Lead stock class designator type class outline finish designator (see 1.2.1) (see 1.2.2) designator (see 1.2.4) (see 1.2.5) / (see 1.2.3) / Drawing number 1.2.1 Radiation hardness assur
7、ance (RHA) designator. RHA marked devices shall meet the MIL-PRF-38534 specified RHA levels and shall be marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device. 1.2.2 Device type(s). The device type(s) identify the circuit function as follows: Device type Generic number Ci
8、rcuit function Frequency Accuracy 1 LSB BIT/VEL 01 SDC-14612II-112 14-bit, 90 V S/D converter 400 Hz 4 min VEL 02 SDC-14612IIT-112 14-bit, 90 V S/D converter 400 Hz 4 min BIT 03 SDC-14614II-112 14-bit, 90 V S/D converter 60 Hz 4 min VEL 04 SDC-14614IIT-112 14-bit, 90 V S/D converter 60 Hz 4 min BIT
9、05 SDC-14617II-112 16-bit, 90 V S/D converter 400 Hz 4 min VEL 06 SDC-14617IIT-112 16-bit, 90 V S/D converter 400 Hz 4 min BIT 07 SDC-14619II-112 16-bit, 90 V S/D converter 60 Hz 4 min VEL 08 SDC-14619IIT-112 16-bit, 90 V S/D converter 60 Hz 4 min BIT 09 SDC-14617II-114 16-bit, 90 V S/D converter 40
10、0 Hz 2 min VEL 10 SDC-14617IIT -114 16-bit, 90 V S/D converter 400 Hz 2 min BIT 11 SDC-14619II-114 16-bit, 90 V S/D converter 60 Hz 2 min VEL 12 SDC-14619IIT-114 16-bit, 90 V S/D converter 60 Hz 2 min BIT 1.2.3 Device class designator. This device class designator shall be a single letter identifyin
11、g the product assurance level. All levels are defined by the requirements of MIL-PRF-38534 and require QML Certification as well as qualification (Class H, K, and E) or QML Listing (Class G and D). The product assurance levels are as follows: Device class Device performance documentation K Highest r
12、eliability class available. This level is intended for use in space applications. H Standard military quality class level. This level is intended for use in applications where non-space high reliability devices are required. G Reduced testing version of the standard military quality class. This leve
13、l uses the Class H screening and In-Process Inspections with a possible limited temperature range, manufacturer specified incoming flow, and the manufacturer guarantees (but may not test) periodic and conformance inspections (Group A, B, C, and D). E Designates devices which are based upon one of th
14、e other classes (K, H, or G) with exception(s) taken to the requirements of that class. These exception(s) must be specified in the device acquisition document; therefore the acquisition document should be reviewed to ensure that the exception(s) taken will not adversely affect system performance. D
15、 Manufacturer specified quality class. Quality level is defined by the manufacturers internal, QML certified flow. This product may have a limited temperature range. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A
16、 5962-92054 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL C SHEET 3 DSCC FORM 2234 APR 97 1.2.4 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows: Outline letter Descriptive designator Terminals Package style X See figure 1 36 Dual-in-line 1.2.5 L
17、ead finish. The lead finish shall be as specified in MIL-PRF-38534. 1.3 Absolute maximum ratings. 1/ Positive supply voltage (VCC) . +7.0 V dc Negative supply voltage (VEE) -7.0 V dc Reference input voltage . 130 V rms Digital input voltage range . -0.3 V dc to +7.0 V dc Power dissipation, TA= +125
18、C (PD) . 550 mW Thermal resistance junction-to-case (qJC) 8.0 C/W Thermal resistance junction-to-ambient (qJA) . 20 C/W Storage temperature range -65 C to +150 C Lead temperature (soldering, 10 seconds) +300 C 1.4 Recommended operating conditions. Positive supply voltage (VCC) . +4.75 V dc to +5.25
19、V dc Negative supply voltage (VEE) -4.75 V dc to -5.25 V dc Reference input voltage range . 10 V rms to 130 V rms Reference input carrier frequency range: Device types 01, 02, 05, 06, 09, and 10 . 360 Hz to 5000 Hz Device types 03, 04, 07, 08, 11, and 12 . 47 Hz to 1000 Hz Signal input voltage range
20、 . 81 V rms to 99 V rms Ambient operating temperature range (TA) -55 C to +125 C 2. APPLICABLE DOCUMENTS 2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part of this drawing to the extent specified herein. Unless otherwise specifie
21、d, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATION MIL-PRF-38534 - Hybrid Microcircuits, General Specification for. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-883 - Test Method Standard Microcircuits. MIL-STD-1835 - Interface Standard f
22、or Electronic Component Case Outlines. DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - List of Standard Microcircuit Drawings. MIL-HDBK-780 - Standard Microcircuit Drawings. (Copies of these documents are available online at http:/assist.daps.dla.mil/quicksearch/ or www.dodssp.daps.mil or from the St
23、andardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text of this drawing takes precedence. Nothing in this document, however, supers
24、edes applicable laws and regulations unless a specific exemption has been obtained. 1/ Stresses above the absolute maximum ratings may cause permanent damage to the device. Extended operation at the maximum levels may degrade performance and affect reliability.Provided by IHSNot for ResaleNo reprodu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLASMD596292054REVC2012MICROCIRCUITHYBRIDLINEAR90VOLTSYNCHROTODIGITALCONVERTERPDF

链接地址:http://www.mydoc123.com/p-700116.html