DLA SMD-5962-89910 REV D-2006 MICROCIRCUIT HYBRID LINEAR HIGH SPEED WIDEBAND OPERATIONAL AMPLIFIER《高速宽带运算放大器 线性混合微型电路》.pdf
《DLA SMD-5962-89910 REV D-2006 MICROCIRCUIT HYBRID LINEAR HIGH SPEED WIDEBAND OPERATIONAL AMPLIFIER《高速宽带运算放大器 线性混合微型电路》.pdf》由会员分享,可在线阅读,更多相关《DLA SMD-5962-89910 REV D-2006 MICROCIRCUIT HYBRID LINEAR HIGH SPEED WIDEBAND OPERATIONAL AMPLIFIER《高速宽带运算放大器 线性混合微型电路》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Added CMRR test to table I. Updated document to current MIL-H-38534 requirements. Editorial changes throughout. 92-01-21 A. Barone B Changes in accordance with NOR 5962-R244-97. 97-03-13 Kendall A. Cottongim C Added vendor CAGE 1HBD3. Removed ven
2、dor CAGE 62839. Made corrections to table I. Editorial changes throughout. -sld 00-06-06 Raymond Monnin D Update drawing. 06-03-01 Raymond Monnin REV SHEET REV SHEET REV STATUS REV D D D D D D D D D D D OF SHEETS SHEET 1 2 3 4 5 6 7 8 9 10 11 PMIC N/A PREPARED BY Gary Zahn DEFENSE SUPPLY CENTER COLU
3、MBUS STANDARD MICROCIRCUIT DRAWING CHECKED BY Robert M. Heber POST OFFICE BOX 3990 COLUMBUS, OHIO 43218-3990 http:/www.dscc.dla.mil THIS DRAWING IS AVAILABLE FOR USE BY ALL DEPARTMENTS APPROVED BY William K. Heckman MICROCIRCUIT, HYBRID, LINEAR, HIGH SPEED, WIDEBAND, OPERATIONAL AMPLIFIER AND AGENCI
4、ES OF THE DEPARTMENT OF DEFENSE DRAWING APPROVAL DATE 90-12-06 AMSC N/A REVISION LEVEL D SIZE A CAGE CODE 67268 5962-89910 SHEET 1 OF 11 DSCC FORM 2233 APR 97 5962-E290-06Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING S
5、IZE A 5962-89910 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 2 DSCC FORM 2234 APR 97 1. SCOPE 1.1 Scope. This drawing documents one product assurance class, class H (high reliability) and a choice of case outlines and lead finishes are available and are reflected
6、in the Part or Identifying Number (PIN). 1.2 PIN. The PIN shall be as shown in the following example: 5962-89910 01 X X Drawing number Device type Case outline Lead finish (see 1.2.1) (see 1.2.2) (see 1.2.3) 1.2.1 Device type(s). The device type(s) shall identify the circuit function as follows: Dev
7、ice type Generic number 1/ Circuit function 01 CLC200A, KH200A High speed, wideband, operational amplifier 1.2.2 Case outline(s). The case outline(s) shall be as designated in MIL-STD-1835 and as follows: Outline letter Descriptive designator Terminals Package style X See figure 1 12 Can package 1.2
8、.3 Lead finish. The lead finish shall be as specified in MIL-PRF-38534. 1.3 Absolute maximum ratings. 2/ Supply voltage (VCC) . 20 V dc Output current . 100 mA Storage temperature range . -65C to +150C Lead temperature (soldering, 10 seconds) +300C Junction temperature (TJ) . +175C Power dissipation
9、 (PD) 3/ Thermal resistance, case-to-ambient (CA) 65C/W 4/ Thermal resistance, junction-to-case: JC(circuit) 32C/W 5/ JC(output) 100C/W 6/ 1/ The CLC200A is not available from an approved source of supply. 2/ Stresses above the absolute maximum ratings may cause permanent damage to the device. Exten
10、ded operation at the maximum levels may degrade performance and affect reliability. 3/ The power dissipation can be determined based on the application and junction temperature verified to be TJ +175C and using the thermal resistance values given. 4/ Still air, no heat sink. 5/ Thermal resistance of
11、 circuit; PCIRCUIT= 2(VCC) ICC. 6/ Thermal resistance of output transistors; POUTPUT= VCE(IE) x (% duty cycle). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-89910 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, O
12、HIO 43218-3990 REVISION LEVEL D SHEET 3 DSCC FORM 2234 APR 97 1.4 Recommended operating conditions. Supply voltage range. 5 V dc to 15 V dc Gain range. 1 to 50 Ambient operating temperature range (TA) . -55C to +125C 2. APPLICABLE DOCUMENTS 2.1 Government specification, standards, and handbooks. The
13、 following specification, standards, and handbooks form a part of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATION MIL-PRF-38534 - Hybrid Microcircuits, General
14、Specification for. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-883 - Test Method Standard Microcircuits. MIL-STD-1835 - Interface Standard for Electronic Component Case Outlines. DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - List of Standard Microcircuit Drawings. MIL-HDBK-780 - Standard Microcircuit D
15、rawings. (Copies of these documents are available online at http:/assist.daps.dla.mil/quicksearch/ or http:/assist.daps.dla.mil or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2 Order of precedence. In the event of a conflict between
16、the text of this drawing and the references cited herein, the text of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Item requirements. The individual item performance req
17、uirements for device class H shall be in accordance with MIL-PRF-38534. Compliance with MIL-PRF-38534 may include the performance of all tests herein or as designated in the device manufacturers Quality Management (QM) plan or as designated for applicable device class. The manufacturer may eliminate
18、, modify or optimize the tests and inspections herein, however the performance requirements as defined in MIL-PRF-38534 shall be met for the applicable device class. In addition, the modification in the QM plan shall not affect the form, fit, or function of the device for the applicable device class
19、. 3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified in MIL-PRF-38534 and herein. 3.2.1 Case outline(s). The case outline(s) shall be in accordance with 1.2.2 herein and figure 1. 3.2.2 Terminal connections. The terminal connect
20、ions shall be as specified on figure 2. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-89910 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 4 DSCC FORM 2234 APR 97 3.3 Electr
21、ical performance characteristics. Unless otherwise specified herein, the electrical performance characteristics are as specified in table I and shall apply over the full specified operating temperature range. 3.4 Electrical test requirements. The electrical test requirements shall be the subgroups s
22、pecified in table II. The electrical tests for each subgroup are defined in table I. 3.5 Marking of device(s). Marking of device(s) shall be in accordance with MIL-PRF-38534. The device shall be marked with the PIN listed in 1.2 herein. In addition, the manufacturers vendor similar PIN may also be m
23、arked. 3.6 Data. In addition to the general performance requirements of MIL-PRF-38534, the manufacturer of the device described herein shall maintain the electrical test data (variables format) from the initial quality conformance inspection group A lot sample, for each device type listed herein. Al
24、so, the data should include a summary of all parameters manually tested, and for those which, if any, are guaranteed. This data shall be maintained under document revision level control by the manufacturer and be made available to the preparing activity (DSCC-VA) upon request. 3.7 Certificate of com
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLASMD596289910REVD2006MICROCIRCUITHYBRIDLINEARHIGHSPEEDWIDEBANDOPERATIONALAMPLIFIER 高速 宽带 运算放大器 线性 混合

链接地址:http://www.mydoc123.com/p-699682.html