DLA SMD-5962-08210 REV A-2012 MICROCIRCUIT HYBRID 12 VOLT SINGLE CHANNEL DC DC CONVERTER.pdf
《DLA SMD-5962-08210 REV A-2012 MICROCIRCUIT HYBRID 12 VOLT SINGLE CHANNEL DC DC CONVERTER.pdf》由会员分享,可在线阅读,更多相关《DLA SMD-5962-08210 REV A-2012 MICROCIRCUIT HYBRID 12 VOLT SINGLE CHANNEL DC DC CONVERTER.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Table I: For power dissipation test, change max limit of non-RHA subgroup 1 from “18” W to “20” W. Table II, add note to Group C end-point test parameters to include subgroups 2 and 3. In paragraph 4.3.5, correct units in table for Single event u
2、pset survival level (LET) from “MeV” to “MeV-cm2/mg”. Update drawing paragraphs. gc 12-03-01 Charles F. Saffle REV SHEET REV SHEET REV STATUS REV A A A A A A A A A A A A A OF SHEETS SHEET 1 2 3 4 5 6 7 8 9 10 11 12 13 PMIC N/A PREPARED BY Steve L. Duncan DLA LAND AND MARITIME STANDARD MICROCIRCUIT D
3、RAWING CHECKED BY Greg Cecil COLUMBUS, OHIO 43218-3990 http:/www.landandmaritime.dla.mil THIS DRAWING IS AVAILABLE FOR USE BY ALL DEPARTMENTS APPROVED BY Robert M. Heber MICROCIRCUIT, HYBRID, 12 VOLT, SINGLE CHANNEL, DC/DC CONVERTER AND AGENCIES OF THE DEPARTMENT OF DEFENSE DRAWING APPROVAL DATE 08-
4、04-15 AMSC N/A REVISION LEVEL A SIZE A CAGE CODE 67268 5962-08210 SHEET 1 OF 13 DSCC FORM 2233 APR 97 5962-E224-12 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-08210 DLA LAND AND MARITIME COLUMBUS, OHIO 43
5、218-3990 REVISION LEVEL A SHEET 2 DSCC FORM 2234 APR 97 1. SCOPE 1.1 Scope. This drawing documents five product assurance classes as defined in paragraph 1.2.3 and MIL-PRF-38534. A choice of case outlines and lead finishes which are available and are reflected in the Part or Identifying Number (PIN)
6、. When available, a choice of radiation hardness assurance levels are reflected in the PIN. 1.2 PIN. The PIN shall be as shown in the following example: 5962 - 08210 01 H X X Federal RHA Device Device Case Lead stock class designator type class outline finish designator (see 1.2.1) (see 1.2.2) desig
7、nator (see 1.2.4) (see 1.2.5) / (see 1.2.3) / Drawing number 1.2.1 Radiation hardness assurance (RHA) designator. RHA marked devices shall meet the MIL-PRF-38534 specified RHA levels and shall be marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device. 1.2.2 Device type(s).
8、 The device type(s) identify the circuit function as follows: Device type Generic number Circuit function 01 SMRT2812S DC/DC converter, 35 W, 12 V output 1.2.3 Device class designator. This device class designator shall be a single letter identifying the product assurance level. All levels are defin
9、ed by the requirements of MIL-PRF-38534 and require QML Certification as well as qualification (Class H, K, and E) or QML Listing (Class G and D). The product assurance levels are as follows: Device class Device performance documentation K Highest reliability class available. This level is intended
10、for use in space applications. H Standard military quality class level. This level is intended for use in applications where non-space high reliability devices are required. G Reduced testing version of the standard military quality class. This level uses the Class H screening and In-Process Inspect
11、ions with a possible limited temperature range, manufacturer specified incoming flow, and the manufacturer guarantees (but may not test) periodic and conformance inspections (Group A, B, C and D). E Designates devices which are based upon one of the other classes (K, H, or G) with exception(s) taken
12、 to the requirements of that class. These exception(s) must be specified in the device acquisition document; therefore the acquisition document should be reviewed to ensure that the exception(s) taken will not adversely affect system performance. D Manufacturer specified quality class. Quality level
13、 is defined by the manufacturers internal, QML certified flow. This product may have a limited temperature range. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-08210 DLA LAND AND MARITIME COLUMBUS, OHIO 432
14、18-3990 REVISION LEVEL A SHEET 3 DSCC FORM 2234 APR 97 1.2.4 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows: Outline letter Descriptive designator Terminals Package style X See Figure 1 12 Flange mount 1.2.5 Lead finish. The lead finish shall be as specified in
15、 MIL-PRF-38534. 1.3 Absolute maximum ratings. 1/ Input voltage range (VIN) -0.5 V dc to +80 V dc Power dissipation (PD): Device type 01 (non-RHA) . 20 W Device type 01 (RHA levels P, R, and F) . 22 W Output power 35 W Lead soldering temperature (10 seconds) . +300C Storage temperature range -65C to
16、+150C 1.4 Recommended operating conditions. Input voltage range (VIN) . +19 V dc to +56 V dc Case operating temperature range (TC) -55C to +125C 1.5 Radiation features. Maximum total dose available (dose rate = 9 rads(Si)/s): Device type 01 (RHA levels P, R and F) 300 krads (Si) 2/ 2. APPLICABLE DOC
17、UMENTS 2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DE
18、FENSE SPECIFICATION MIL-PRF-38534 - Hybrid Microcircuits, General Specification for. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-883 - Test Method Standard Microcircuits. MIL-STD-1835 - Interface Standard for Electronic Component Case Outlines. DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - List of Stan
19、dard Microcircuit Drawings. MIL-HDBK-780 - Standard Microcircuit Drawings. (Copies of these documents are available online at http:/assist.daps.dla.mil/quicksearch/ or http:/assist.daps.dla.mil or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5
20、094.) 1/ Stresses above the absolute maximum ratings may cause permanent damage to the device. Input voltage transients between 56 and 80 volts are allowed for no more than 120 milliseconds. Extended operation at the maximum levels may degrade performance and affect reliability. 2/ These parts may b
21、e dose rate sensitive in a space environment and may demonstrate enhanced low dose rate effects. Radiation end-point limits for the noted parameters are guaranteed only for the conditions as specified in MIL-STD-883, Method 1019, condition C, tested at 9 rads(Si)/s. Provided by IHSNot for ResaleNo r
22、eproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-08210 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 4 DSCC FORM 2234 APR 97 2.2 Order of precedence. In the event of a conflict between the text of this drawing and the
23、 references cited herein, the text of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Item requirements. The individual item performance requirements for device classes D,
24、E, G, H, and K shall be in accordance with MIL-PRF-38534. Compliance with MIL-PRF-38534 may include the performance of all tests herein or as designated in the device manufacturers Quality Management (QM) plan or as designated for the applicable device class. The manufacturer may eliminate, modify o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLASMD596208210REVA2012MICROCIRCUITHYBRID12VOLTSINGLECHANNELDCDCCONVERTERPDF

链接地址:http://www.mydoc123.com/p-698412.html