1、Beneficial comments, recommendations, additions, deletions, clarifications, etc. and any data that may improve this document should be sent to: STDZNMGTdla.mil or Defense Logistics Agency Aviation VEB, 8000 Jefferson Davis Highway, Richmond, VA 23297-5616. Since contact information can change, you m
2、ay want to verify the currency of this address information using the ASSIST database at https:/assist.daps.dla.mil/. AMSC N/A FSC 6810 METRIC O-B-41H 16 November 2010 SUPERSEDING O-B-41G 31 May 2005 FEDERAL SPECIFICATION BATTERY WATER The General Services Administration has authorized the use of thi
3、s federal specification by all federal agencies. 1. SCOPE AND CLASSIFICATION 1.1 Scope. This specification covers one type of battery water that is used in lead-acid storage batteries. 2. APPLICABLE DOCUMENTS 2.1 Other publications. The following documents form a part of this specification to the ex
4、tent specified herein. Unless a specific issue is identified, the issue in effect on the date of invitation for bids or request for proposal shall apply. ASTM International ASTM D511 - Standard Test Methods for Calcium and Magnesium In Water ASTM D512 - Standard Test Methods for Chloride Ion In Wate
5、r ASTM D1068 - Standard Test Methods for Iron in Water ASTM D1193 - Standard Specification for Reagent Water ASTM D1426 - Standard Test Methods for Ammonia Nitrogen In Water ASTM D1688 - Standard Test Methods for Copper in Water ASTM D1886 - Standard Test Methods for Nickel in Water Provided by IHSN
6、ot for ResaleNo reproduction or networking permitted without license from IHS-,-,-O-B-41H 2 ASTM International - Continued ASTM D6317 - Standard Test Method for Low Level Determination of Total Carbon, Inorganic Carbon and Organic Carbon in Water by Ultraviolet, Persulfate Oxidation, and Membrane Co
7、nductivity Detection (Private sector and civil agencies may purchase copies of these voluntary standards from ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. Electronic copies may be obtained from http:/www.astm.org/.) Waters Corporation Method B-1011 - Th
8、e Determination of Nitrite and Nitrate in Water Using Single Column Ion Chromatography 980896 - Anion Analysis Using Hydroxide Eluent and Indirect Conductivity Detection and EPA Method B-1011 for Nitrite and Nitrate Using UV Detection (Private sector and civil agencies may purchase copies of these v
9、oluntary standards from Waters Corporation, 34 Maple Street, Milford, MA 01757. Electronic copies may be obtained from http:/ 3. REQUIREMENTS 3.1 Physical characteristics. The battery water shall be clear, colorless, odorless, and free from suspended matter and sediment when tested as specified in 4
10、.3.1.1. 3.2 Impurities. The battery water shall conform to the maximum allowable impurity requirements shown in table I when tested in accordance with the applicable test paragraphs and test standards listed in table I. TABLE I. Maximum allowable impurities. Impurity Maximum (mg/L)1Test paragraph Te
11、st standard Total solids 100 4.3.1.2 ASTM D63172Organic and volatile matter 50 4.3.1.2 ASTM D63172Calcium and magnesium (total) 40 4.3.1.3 ASTM D511 Iron 0.5 4.3.1.4 ASTM D1068 Copper 2.5 4.3.1.5 ASTM D1688 Chloride 5 4.3.1.6 ASTM D512 Nickel 0.2 4.3.1.7 ASTM D1886 Ammonia (as NH4) 8 4.3.1.8 ASTM D1
12、426 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-O-B-41H 3 TABLE I. Maximum allowable impurities - Continued. Impurity Maximum (mg/L)1Test paragraph Test standard Nitrites (as NO2) 5 4.3.1.9 Waters Corp. document 9808962Nitrates (as NO3) 10 4.3.1.
13、10 Waters Corp. document 98089621When specific gravity is unity, the concentration of aqueous solute in milligrams per liter (mg/L) of solution will equal the parts per million (ppm). The concentration in micrograms per liter (g/L) will equal the parts per billion (ppb). When specific gravity is not
14、 equal to unity, mg/L or g/L divided by the specific gravity of the solution will equal ppm or ppb, respectively. 2Test measurements conducted in accordance with the indicated test standards are expressed in g/L and should be converted to the mg/L equivalent using 1 mg/L = 1000 g/L. 4. QUALITY ASSUR
15、ANCE PROVISIONS 4.1 Responsibility for inspection. Unless otherwise specified in the acquisition order (see 6.2), the contractor is responsible for the performance of all inspection requirements (examinations and tests) specified herein. Except as otherwise specified in the acquisition order (see 6.
16、2), the contractor may use his own or any other facilities suitable for the performance of the inspection requirements specified herein, unless disapproved by the Government. The Government reserves the right to perform any of the inspections set forth in this specification where such inspections ar
17、e deemed necessary to ensure supplies and services conform to prescribed requirements. 4.1.1 Responsibility for compliance. All items supplied to the Government shall meet all requirements of sections 3 and 5. The inspection set forth in this specification shall become a part of the contractors over
18、all inspection system or quality program. The absence of any inspection requirements in the specification shall not relieve the contractor of the responsibility of ensuring that all products or supplies submitted to the government for acceptance comply with all requirements of the contract. Sampling
19、 inspection, as part of the manufacturing operations, is an acceptable practice to ascertain conformance to requirements, however, this does not authorize submission of known defective material, either indicated or actual, nor does it commit the Government to accept defective material. 4.1.2 Contrac
20、tor assurance of compliance. The contractors quality program or detailed inspection system shall provide assurance of compliance of all characteristics with the applicable drawing and specification requirements using, as a minimum, the conformance criteria specified herein. 4.1.3 Alternative inspect
21、ion provisions. When specified in the acquisition order (see 6.2), alternative inspection provisions, methods, or equipment such as statistical process control, tool control, and other types of sampling procedures may be used by the contractor when they provide, as a minimum, the level of quality as
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAOB41H2010BATTERYWATERPDF