1、MIL-W-36775A bb 7977906 0337323 4 E-= -1 I . MIL-W-36775A( DLA-DM) 28 February 1979 SUPERSEDING MIL-W-36775 (DSA-DM) 27 August 1971 MILITARY SPECIFICATION WET BULB-GLOBE TEMPERATURE KIT This limited coordination military specification has been prepared by the Defense Personnel Support Center based u
2、pon currently available technical information. It is subject to modification. coordinated military specification, it may be used in pro- curemen t. However, pending its promulgation as a 1. SCOPE 1.1 Scope. This specificat on covers a small lightweight hand-held wet bulb-globe temperature kit for pr
3、oviding an index of heat stress in out- door areas of hot and humid cl mates, in order to control and prevent heat casualties during troop training exercises. The heat stress index is com- puted by the weighted addi tion of readings obtained from three different thermometers. 2. APPLICABLE DOCUMENTS
4、 2.1 Issues of documents. The following documents of the issue in effect on date of invitation for bids or request for proposals, form a part of this specification to the extent specified herein. SPEC1 FICAT IONS FEDERAL i r P-C-436 - Cleaning Compound, Al ka1 i, Boiling Vat. I -_ TT- E- 527 TT-P-17
5、57 - Enamel , Alkyd, Lustreless. - Lacquer, Ni troce1 1 Ulose, Acryl i c and Acryl i c-Butyrate , - Primer Coating, Zinc Chromate, Low-Moisture-Sensitivity. - TT-L-50 Aerosol (in Pressurized Dispensers). Beneficial comments (recommendations, additions, deletions) and any perti- nent data which may b
6、e of use in improving this document should be addressed to: Headquarters , Defense Personnel Support Center, ATTN: Di rectorate of Medi cal Materiel , CODE-ATT, 2800 South 20th Street, Phi 1 adel phi a, PA 191 O1 , by using the self-addressed Standardization Document Improvement Proposal (DD Form 14
7、26) appearaing at the end of this document or by letter. FSC 6665 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MI L-W-36775A( DLA- DM) PPP-B-566 - Boxes Fol ding , Paperboard. PPP-B-636 PPP-B-676 - Boxes, Setup. - Boxes , Fi berboard. STANDARDS M
8、I L ITARY MIL-STD-105 MIL-STD-129 MIL-STD-171 Sampling Procedures and Tables Por Inspection by - Marking for Shipment and Storage. - Finishing of Metal and Wood Surfaces, Attributes. DRAWING DEFENSE PERSONNEL SUPPORT CENTER (DPSC) 25072 - Wet Bulb Globe Temperature Kit. connection with specific proc
9、urement functions should be obtained from the procuring activity or as directed by the contracting officer) fication to the extent specified herein, Unless otherwise indicated, the issue in effect on date of invitation for bids or request for proposals shall apply (Copies of specifications, standard
10、s and drawing required by contractor in 2.2 Other publicatlons. The following documents form a part of this speci- AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) ASTM Designation E77-66 - Verification and Cali bration of Liquid-in-Glass Thermometers. (Application for copies should be addressed to
11、 American Society for Testing DEPARTMENT OF THE ARMY TECHNICAL BULLETIN and Materials, 1916 Race Street, Philadelphia, PA 19103). TB-MED-175 - The Etiology, Prevention, Diagnosis, and Treatment OP Adverse Effect of Heat. (For information purposes only). 2 Provided by IHSNot for ResaleNo reproduction
12、 or networking permitted without license from IHS-,-,-MIL-W-3b775A bb = 77777Ob 0337325 B a . a t 1 MIL-W-36775A (DLA-DM) 3. REQUIREMENTS 3.1 Materials and components. The materials and components shall be suit- able for the intended purposes and shall conform to the requirements of DPSC Drawing No.
13、 25072 and the associated Bill of Materials. 3.1.1 Thermometer graduations. All thermometers, within their specified ranges, shall be graduated in 1 degree F. subdivisions and numbered at least at every 1OOF. markings. When tested as specified, the accuracy of the ther- mometers used for black-globe
14、, dry bulb, and wet bulb temperature indication shall be f lOF. (see 4.4.1). 3.1.2 Slide rule calculations. When ,tested as specified, the WBGT s rule readings shall agree with table IV (see 4.4.2). i de 3.2 Design and constructlon. The kit shall consist of a thermometer assembly and a slide rule as
15、sembly that is contained in a portable case The kit shall be in strict accordance with DPSC Drawing for style, dimensions and constructton. In addition, identification marking per 3.6 shall be included on each kit. The kit shall weigh no more than 20 ounces. 3.2.1 Finish and color. 3.2.1.1 Hinged bo
16、x and cover. The hinged aluminum box and cover shall be treated according to P-C-436 prior to painting. The outside of the box and cover including the hinge shall be primed according to TT-P-1757 and shall be finished with two coats of baked lusterless enamel according to TT-E-527. The color shall b
17、e olive drab approximating Federal Standard 595 Color No. 34087. 3.2.1.2 Sunshade. The sunshade shall be treated and painted as specified in 3.2.1.1. The color shall be white. The lettering and markings on the sunshade chal 1 be black. 3.2.1.3 Sheath, radiant energy. The radiant energy sheath shall
18、be colored black using a flat lacquer which conforms to TT-L-50. 3.3 Performance. The wet bu1 b-globe temperature kit shall operate in accord- 3.4 Accessories. The following additional replacement parts shall be in- ance with the instructions included in 3.5. cluded with each kit. 1 each transparent
19、 perforated shield. 1 each water reservoir. 18 inch extra wick. The replacement parts shall be in accordance with DPSC Drawing No. 25072 and Bill of Materials and shall be contained in the case above the cushion mat. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without lice
20、nse from IHS-,-,-MIL-W-36775A (DLA-DM) 3.5 Service data. data which specifically includes the following instructions and figure (i., see figure I), Each kit shall be furnished with two copies of service GENERAL INSTRUCTIONS WET BULB-GLOBE TEMPERATURE KIT NSN 6665-00-1 59-2218 A. The wet bulb-globe t
21、emperature kit is an instrument for providing information on hot weather risks to the health of troops undergoing training, The information is displayed on a scale In the form of an index, computed from the weighed readlngs obtained from three diferent thermometers, prevailing wind. black sheath ove
22、r the bulb. The sheath and bulb are inside a transparent perforated plastic shield. direct rays of the sun by a shield painted white. of the wet bulb (WB) temperature reading plus 20% of the black globe (BG) temperature reading plus 10% of the dry bulb (DB) temperature reading and can be computed as
23、 follows: 1. A stationary wet bulb (.WB) thermometer exposed to the sun and 2. A similarly exposed “black globe (BG) thermometer with a 3. A dry bulb (DB) thermometer with its bulb shielded from the B, The wet bulb-globe temperature index (WBGT index) is equal to 70% WBGT Index = 0.7 WB + 0.2 BG + 0
24、.1 DB Use of the attached slide rule provides the correct WBGT index automatically. ing guide 1 ines from TB-MED-175 are provided, planning exercise for unseasoned personnel o marching at standard kadence should be suspended for unseasoned personnel dur- ing their first three weeks of training. At t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILW36775A1979WETBULBGLOBETEMPERATUREKIT 温度 试剂盒 PDF

链接地址:http://www.mydoc123.com/p-693673.html