DLA MIL-PRF-6106 M-2009 RELAYS ELECTROMAGNETIC GENERAL SPECIFICATION FOR.pdf
《DLA MIL-PRF-6106 M-2009 RELAYS ELECTROMAGNETIC GENERAL SPECIFICATION FOR.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-PRF-6106 M-2009 RELAYS ELECTROMAGNETIC GENERAL SPECIFICATION FOR.pdf(60页珍藏版)》请在麦多课文档分享上搜索。
1、AMSC N/A FSC 5945 MIL-PRF-6106M 14 September 2009 SUPERSEDING MIL-PRF-6106L 10 November 2000 PERFORMANCE SPECIFICATION RELAYS, ELECTROMAGNETIC GENERAL SPECIFICATION FOR This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This speci
2、fication establishes general requirements for electromechanical relays with contact ratings from 25 amperes resistive (unless otherwise specified) and upward for use in electrical applications. Auxiliary contacts may be rated at lower currents. Relays covered by this specification are capable of mee
3、ting the electrical and environmental requirements when mounted directly to the structure of aircraft, missile, spacecraft, ship, and other primary vehicles or in ground support and shipboard equipment. Other ratings may be as specified (see 3.1). CAUTION: The use of any coil voltage less than the r
4、ated coil voltage will compromise the operation of the relay. For additional application and caution information, see 6.1. 1.2 Classification. Relays covered by this specification will be classified by the type specified in 1.2.1 (see 3.1 and 6.1). 1.2.1 Type designators. The type is identified by o
5、ne of the following designators: Type I: Continuous duty, hermetically sealed. Type II: Continuous duty, unsealed. Type III: Intermittent duty (hermetically sealed, environmentally sealed, unsealed). Type IV: Continuous duty, environmentally sealed, (nonhermetic). 1.2.2 Class “O“ relays. Information
6、 concerning Class “O“ relays is covered in 6.11. 1.2.3 Part or Identifying Number (PIN). The PIN will consist of the letter “M“; the basic specification number; the specification sheet number; and an assigned dash number (see 3.1) as shown in the following example. (NOTE: The PIN format for relays c
7、overed by Military Standards (MS) sheets and Air Force-Navy (AN) Aeronautical standards are to be as specified therein; see 3.1.) M6106 /20 -001 I I I I I I I I I Specification Specification Dash number designator sheet number INCH-POUND Comments, suggestions or questions on this document should be
8、addressed to Defense Supply Center Columbus, ATTN: VAT, Post Office Box 3990, Columbus, OH 43218-3990, or emailed to relaydla.mil. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at http:/assist.daps.dla.mil. Prov
9、ided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106M 2 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sect
10、ions of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of documents cited in sections 3 and 4 of this specification, whe
11、ther or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the
12、solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-PRF-6106/12 - Relay, Electromagnetic, (Type I), Magnetic Latch, 25 Amperes, 3PNO Main Contacts, with 2 Ampere, 1PDT Auxillary Contacts, Hermetically Sealed. MIL-PRF-6106/13 - Relay, Electromagnetic, 25 Amperes, 3PST, NO, with 2 Amper
13、e, 1 PDT Auxiliary Contacts, Hermetically Sealed, Permanent Magnet Drive, Type I. MIL-PRF-6106/19 - Relay, Electromagnetic, Magnetic Latch, 25 Amperes, SPDT, Hermetically Sealed. MIL-PRF-6106/20 - Relay, Electromagnetic, Magnetic Latch, 25 Amperes, SPDT, Hermetically Sealed. MIL-PRF-6106/38 - Relay,
14、 Electromagnetic, Type I, Magnetic Latch, Permanent Magnet Drive, Low Level to 5 Amperes, 2 PDT, Hermetically Sealed. MIL-PRF-6106/39 - Relay, Electromagnetic, Type I Magnetic Latch, Permanent Magnet Drive, Low Level to 5 Amperes, 4 PDT, Hermetically Sealed. MIL-PRF-6106/40 - Relay, Electromagnetic,
15、 Type I, Magnetic Latch, Permanent Magnet Drive, Low Level to 10 Amperes, 3 PDT, Hermetically Sealed. (See supplement 1 for list of other specification sheets.) FEDERAL STANDARDS FED-STD-H28 - Screw Thread Standards for Federal Services. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-202 - Electronic and E
16、lectrical Component Parts. MIL-STD-750 - Semiconductor Devices, Test Methods for. MIL-STD-790 - Established Reliability and High Reliability Qualified Products List (QPL) Systems for Electrical, Electronic, and Fiber Optic Parts Specifications. MIL-STD-883 - Microelectronics. MIL-STD-1276 - Leads fo
17、r Electronic Component Parts. MIL-STD-1285 - Marking of Electrical and Electronic Parts. MS27742(USAF) - Relays, Electromagnetic, Type I, Magnetic Latch, 25 Amperes, 3 PDT, All Welded, Hermetically Sealed. (Copies of these documents are available online at http:/assist.daps.dla.mil/ or from the Stan
18、dardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.3 Non-Government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solic
19、itation or contract. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) ANSI Y32.2 - Electrical and Electronics Diagrams. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106M 3 (Applications for copies are available online at http:/www.ansi.org or
20、 should be addressed to American National Standards Institute (ANSI), 11 West 42ndStreet, New York, NY 10036-8002.) AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) ASTM D470 - Crosslinked Insulations and Jackets for Wire and Cable. (Application for copies are available online at http:/www.astm.org
21、 or should be addressed to ASTM International PO Box C700, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959.) ELECTRONIC INDUSTRIES ASSOCIATION (EIA) EIA-557 - Statistical Process Control Systems. (Applications for copies are available online at http:/www.eia.org/ or should be addressed to th
22、e ECA/EIA Standards and Technology, 2500 Wilson Boulevard, Arlington, VA 22201-3834). SOCIETY OF AUTOMOTIVE ENGINEERS (SAE International) SAE-AS20659 - Terminal Lug, Crimp Style, Copper, Uninsulated, Ring-Tongue, Type I, Class 1, for 175C Total Conductor Temperature. SAE-AS25036 - Terminal Lug, Crim
23、p Style, Copper, Insulated, Ring-Tongue, Bell-mouthed, Type II, Class 1 (for 105C Total Conductor Temperature). (Applications for copies are available online at http:/www.sae.org/ or should be addressed to SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001.) 2.4 Order of precedence
24、. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this document and the references cited herein (except for related specification sheets), the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and re
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILPRF6106M2009RELAYSELECTROMAGNETICGENERALSPECIFICATIONFORPDF

链接地址:http://www.mydoc123.com/p-692989.html