DLA MIL-PRF-6106 33 E-2011 RELAY ELECTROMAGNETIC TYPE I 400 AMPERES WITH 5 AMPERE AUXILIARY CONTACTS PERMANENT MAGNET DRIVE HERMETICALLY SEALED.pdf
《DLA MIL-PRF-6106 33 E-2011 RELAY ELECTROMAGNETIC TYPE I 400 AMPERES WITH 5 AMPERE AUXILIARY CONTACTS PERMANENT MAGNET DRIVE HERMETICALLY SEALED.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-PRF-6106 33 E-2011 RELAY ELECTROMAGNETIC TYPE I 400 AMPERES WITH 5 AMPERE AUXILIARY CONTACTS PERMANENT MAGNET DRIVE HERMETICALLY SEALED.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、AMSC N/A FSC 5945 INCH-POUND MIL-PRF-6106/33E 22 February 2011 SUPERSEDING MIL-PRF-6106/33D 10 November 2000 PERFORMANCE SPECIFICATION SHEET RELAY, ELECTROMAGNETIC, TYPE I, 400 AMPERES, WITH 5 AMPERE AUXILIARY CONTACTS, PERMANENT MAGNET DRIVE, HERMETICALLY SEALED This specification is approved for u
2、se by all Departments and Agencies of the Department of Defense. The requirements for acquiring the relay described herein shall consist of this specification and the latest issue of MIL-PRF-6106 FIGURE 1. Dimensions and configurations.Provided by IHSNot for ResaleNo reproduction or networking permi
3、tted without license from IHS-,-,-MIL-PRF-6106/33E 2 Inches mm Inches mm .090 2.29 .970 24.60 .138 3.51 1.440 36.60.250 6.35 1.500 38.10 .266 6.76 1.930 49.00.330 8.40 2.000 50.80 .350 8.90 2.120 53.85.375 9.53 2.260 57.40 .380 9.65 2.940 74.70.550 14.00 3.000 76.20 .700 17.80 3.640 92.46 .720 18.30
4、 3.900 99.06NOTES 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. There shall be affixed to the relay a suitable legible circuit diagram that identifies each terminal location specified. 4. Permanent magnet drive consists of a permanent magnet with its f
5、lux path switched and combined with the electro-magnet flux. 5. Unless otherwise specified, tolerance is .020 (0.50 mm) for three place decimals and .03 (0.8 mm) for two place decimals. FIGURE 1. Dimensions and configurations - Continued. Provided by IHSNot for ResaleNo reproduction or networking pe
6、rmitted without license from IHS-,-,-MIL-PRF-6106/33E 3 FIGURE 2. Circuit diagrams and terminal configurations. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106/33E 4 NOTES: 1. To identify circuit diagrams, coil diagrams, and terminal con
7、figurations, see table I. 2. Number of terminals varies dependent upon number of auxiliary contacts. 3. Semiconductors shall be JANTX or JANTX screened. Coil diagram 3 shall continue to operate should the suppression circuit be in a failure mode (not applicable to coil diagram 2). Diodes shall have
8、a peak inverse voltage rating of 600 V dc minimum. FIGURE 2. Circuit diagrams and terminal configurations - Continued. REQUIREMENTS: Dash numbers and physical characteristics: See table I. Duty rating: Continuous. Coil data: See table II. Operational data: See table II. Contact data: See tables III
9、and IV. Contact voltage drop: Initial: 0.150 volt. After life: 0.175 volt. Overload current: 3,200 amperes dc. Rupture current: 4,000 amperes dc. Interrupt current: Carry 2,000 amperes for 7 seconds and break five times (30 minutes off per cycle). Provided by IHSNot for ResaleNo reproduction or netw
10、orking permitted without license from IHS-,-,-MIL-PRF-6106/33E 5 ELECTRICAL CHARACTERISTICS: Insulation resistance, initial: 100 megohms at 500 V dc. After life or environmental tests: 50 megohms. Dielectric withstanding voltage (sea level): Initial After life tests Coil to case 1,250 V rms 1,000 V
11、rms Auxiliary contacts 1,250 V rms 1,000 V rms All other points 1,500 V rms 1,250 V rms Dielectric withstanding voltage (altitude): 50,000 feet Coil to case 500 V rms Auxiliary contacts 500 V rms All other points 700 V rms Physical: Dimensions and configuration: See figure 1. Weight (maximum): 1.75
12、pounds. Terminal type: See figure 1, figure 2, and table II. Strength of terminals and mounting studs: Applicable. Seal: Hermetic. Finish: Painted. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106/33E 6 TABLE I. Mechanical and physical ch
13、aracteristics. Dash numbers Coil suppression (back EMF) Circuit diagram Coil diagram Cover height dimensions Terminal lengths 040 Not applicable B1 1 3.38 0.75 041 Applicable B1 3 3.38 0.75042 Applicable B1 3 3.38 0.75 043 Not applicable B1 1 3.38 0.75 044 Applicable B2 3 3.38 1.13045 Not applicable
14、 B2 1 3.38 1.13 046 Applicable A1 3 3.38 0.75047 Applicable A2 3 3.38 0.75 048 Not applicable A1 1 3.38 0.75 049 Not applicable A2 1 3.38 0.75 050 Applicable B2 3 3.38 0.75051 Not applicable B2 1 3.38 0.75 052 Applicable B3 3 3.38 1.13053 Not applicable B3 1 3.38 1.13 054 Applicable B3 3 3.38 0.7505
15、5 Not applicable B3 1 3.38 0.75 056 Applicable C1 3 Not applicable 1.13057 Not applicable C1 1 Not applicable 1.13 058 Applicable C1 3 Not applicable 0.75059 Not applicable C1 1 Not applicable 0.75 060 Applicable B2 2 3.38 1.13061 Applicable B3 2 3.38 1.13 062 Applicable C1 2 Not applicable 1.13063
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILPRF610633E2011RELAYELECTROMAGNETICTYPEI400AMPERESWITH5AMPEREAUXILIARYCONTACTSPERMANENTMAGNETDRIVEHERMETICALLYSEALEDPDF
链接地址:http://www.mydoc123.com/p-692980.html