DLA MIL-PRF-6106 19 G-2011 RELAY ELECTROMAGNETIC PERMANENT MAGNET DRIVE 25 AMPERES SPDT HERMETICALLY SEALED.pdf
《DLA MIL-PRF-6106 19 G-2011 RELAY ELECTROMAGNETIC PERMANENT MAGNET DRIVE 25 AMPERES SPDT HERMETICALLY SEALED.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-PRF-6106 19 G-2011 RELAY ELECTROMAGNETIC PERMANENT MAGNET DRIVE 25 AMPERES SPDT HERMETICALLY SEALED.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、 AMSC N/A FSC 5945 MIL-PRF-6106/19G 18 November 2011 SUPERSEDING MIL-PRF-6106/19F 10 November 2000 PERFORMANCE SPECIFICATION SHEET RELAY, ELECTROMAGNETIC PERMANENT MAGNET DRIVE, 25 AMPERES, SPDT, HERMETICALLY SEALED This specification is approved for use by all Departments and Agencies of the Depart
2、ment of Defense. The requirements for acquiring the relay described herein shall consist of this specification sheet and MIL-PRF-6106. FIGURE 1. Relay, outline drawing. INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106/19G 2 FIG
3、URE 1. Relay, outline drawing - Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106/19G 3 FIGURE 1. Relay, outline drawing - Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-
4、,-,-MIL-PRF-6106/19G 4 Inches mm Inches Mm Inches mm .001 0.03 .156 3.96 .525 13.34 .002 0.05 .172 4.37 .562 14.27 .003 0.08 .234 5.94 .625 15.88 .005 0.13 .250 6.35 .630 16.00 .020 0.51 .270 6.86 1.010 25.65 .040 1.02 .281 7.14 1.025 26.04 .050 1.27 .300 7.62 1.062 26.97 .062 1.57 .375 9.52 1.396 3
5、5.46 .093 2.36 .432 10.97 1.406 35.71 .100 2.54 .485 12.32 1.446 36.73 .150 3.61 .500 12.70 1.718 43.64 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Unless otherwise specified, tolerance is .010 (0.25 mm). 4. Terminal numbers need not appear on
6、 the relay header provided there is a suitable legible circuit diagram affixed to the relay that identifies each terminal location specified. 5. Relay must not operate or become damaged by reverse polarity. Semiconductors shall not be used for this purpose. 6. Hook terminals will accept one no. 12 A
7、WG stranded wire. 7. Permanent magnet drive consists of permanent magnet with its flux path switched and combined with the electromagnetic flux. 8. Socket pin terminals shall provide the operational, environmental, and interface characteristics to provide a reliable interconnect to gold-plated conta
8、cts. Terminals shall be gold plated. Gold plating of the polarizing pin is optional. One system for gold plating that may be used is ASTM B488, type 3, class 1.25 with a nickel underplate of 50 to 150 microinches thick. The gold plating system shall enable the product to meet the performance require
9、ments of this specification and shall be approved by the qualifying activity. 9. Gasket shall provide a reliable seal between the relay and mating socket that will meet the environmental, operational, and interface requirements of the relay with the mating socket. The gasket shall have shore hardnes
10、s 20 5, thickness .050 .005. Gasket material according to SAE-AMS 3332 has been considered acceptable. FIGURE 1. Relay, outline drawing - Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106/19G 5 TABLE I. Mechanical and electrical
11、 characteristics. Dash number Relay type Coil 1/ 2/ suppression Terminal type Mounting Configuration Coil circuit Time current relay characteristic at 25C -003 I Not applicable Solder hook A A Not applicable -004 I Not applicable Socket, pin A A Not applicable -005 I 3/ Not applicable Solder, pin A
12、A Applicable -006 I 3/ Not applicable Solder hook A A Applicable -007 I 3/ Not applicable Socket, pin A A Applicable -008 I 3/ Not applicable Solder, pin B A Applicable -009 I 3/ Not applicable Solder hook B A Applicable -010 I Not applicable Solder, pin A A Applicable -011 I Not applicable Solder h
13、ook A A Applicable -012 I Not applicable Socket, pin A A Applicable -013 I Not applicable Solder, pin B A Applicable -014 I Not applicable Solder hook B A Applicable -015 I 42 V dc, max Solder, pin A B Applicable -016 I 42 V dc, max Solder hook A B Applicable -017 I 42 V dc, max Socket, pin A B Appl
14、icable -018 I 42 V dc, max Solder, pin B B Applicable -019 I 42 V dc, max Solder hook B B Applicable -020 I 3/ 42 V dc, max Solder, pin A B Applicable -021 I 3/ 42 V dc, max Solder hook A B Applicable -022 I 3/ 42 V dc, max Socket, pin A B Applicable -023 I 3/ 42 V dc, max Solder, pin B B Applicable
15、 -024 I 3/ 42 V dc, max Solder hook B B Applicable -025 I Not applicable Solder hook B A Not applicable 1/ Relays using suppression devices shall continue to operate should the suppression circuit be in a failure mode. 2/ Diodes shall have a peak inverse voltage of 600 V dc minimum when used and sha
16、ll be JANTX or JANTX screened after 30 December 1980. 3/ Screened relays shall be tested to group A1 inspections of the group A inspection table. Additional life testing is not required. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-TABLE II. Dash
17、numbers and operating characteristics. Dash No. Coil terminal Coil data Time (milliseconds) (max) Nominal Maximum Max pickup voltage Hold voltage 2/ Dropout voltage 2/ Oper. 3/ Rel. 4/ Contact bounce Break bounce NO only 5/ Volts 1/ Freq. Hz Res. ohms 10% at 25C Volts Amp Norm 2/ High temp test Cont
18、. curr. Main Aux NO NC NO NC -003 through -025 X1 - X2 28 dc 320 29 0.11 18 19.8 22.5 7.0 1.5 10 10 1.0 1.0 - - 0.10 1/ CAUTION: Use of any coil voltage less than nominal coil voltage will compromise the operation of the relay. 2/ Over the temperature range. 3/ With nominal coil voltage. 4/ From nom
19、inal coil voltage. 5/ Applicable to dash numbers 015 through 024 only. MIL-PRF-6106/19G 6 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106/19G 7 REQUIREMENTS: Contact data: Load ratings: See table III. Intermediate current: Applicable. Mi
20、xed loads: Applicable. TABLE III. Rated contact load (amperes per pole) (case grounded). Type of load Endurance Life Operating cycles X 103 28 V dc 115 V ac, 1 phase 115/200 V ac, 3 phase 1/ 400 Hz 400 Hz 60 Hz Resistive 2/ 50 25 25 Inductive 10 12 - Inductive 20 - 15 Motor 50 10 10 Lamp 50 5 5 Tran
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILPRF610619G2011RELAYELECTROMAGNETICPERMANENTMAGNETDRIVE25AMPERESSPDTHERMETICALLYSEALEDPDF

链接地址:http://www.mydoc123.com/p-692977.html