《DLA MIL-PRF-6106 12 F-2011 RELAY ELECTROMAGNETIC (TYPE I) MAGNETIC LATCH 25 AMPERES 3PNO MAIN CONTACTS WITH 2 AMPERE 1PDT AUXILIARY CONTACTS HERMETICALLY SEALED.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-PRF-6106 12 F-2011 RELAY ELECTROMAGNETIC (TYPE I) MAGNETIC LATCH 25 AMPERES 3PNO MAIN CONTACTS WITH 2 AMPERE 1PDT AUXILIARY CONTACTS HERMETICALLY SEALED.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、AMSC N/A FSC 5945 INCH-POUND MIL-PRF-6106/12F 1 November 2011 SUPERSEDING MIL-PRF-6106/12E 23 April 2001 PERFORMANCE SPECIFICATION SHEET RELAY, ELECTROMAGNETIC (TYPE I), MAGNETIC LATCH, 25 AMPERES, 3PNO MAIN CONTACTS, WITH 2 AMPERE 1PDT AUXILIARY CONTACTS, HERMETICALLY SEALED Inactive for new design
2、 after 15 November 2002. No superseding document. This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the relay described herein shall consist of this specification and the MIL-PRF-6106. FIGURE 1. Relay, outline drawing.
3、 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106/12F 2 FIGURE 1. Relay, outline drawing - Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106/12F 3 Inches mm Inches mm
4、 Inches mm .001 0.03 .156 3.96 .600 15.24 .002 0.05 .172 4.37 .625 15.88 .003 0.08 .234 5.94 .630 16.00 .005 0.13 .250 6.35 .937 23.80 .020 0.51 .270 6.86 1.010 25.65 .040 1.02 .300 7.62 1.025 26.04 .050 1.27 .312 7.92 1.062 26.97 .062 1.57 .385 9.78 1.396 35.46 .093 2.36 .395 10.03 1.406 35.71 .117
5、 2.97 .432 10.97 1.446 36.73 .150 3.81 .450 11.43 1.718 43.64 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Unless otherwise specified, tolerance is .010 (0.25 mm). 4. There shall be affixed to the relay a legible circuit diagram that identifies
6、 each terminal location specified. 5. Notes to observe polarity must appear on relays. 6. To close main contact, (operate) energize X1 and X2. To open main contacts, (reset) energize Y1 and Y2. 7. Hook terminals will accept one no. 12 AWG stranded wire. 8. Socket pin terminals shall provide the oper
7、ational, environmental, and interface characteristics to provide a reliable interconnect to gold-plated contacts. Terminals shall be gold plated. Gold plating of the polarizing pin is optional. One system for gold plating that may be used is ASTM B488, type 3, class 1.25 with a nickel underplate of
8、50 to 150 microinches thick. The gold plating system shall enable the product to meet the performance requirements of this specification and shall be approved by the qualifying activity. 9. Gasket shall provide a reliable seal between the relay and mating socket that will meet the environmental, ope
9、rational, and interface requirements of the relay with the mating socket. The gasket shall have shore hardness 20 5, thickness .050 .005. Gasket material according to SAE-AMS 3332 has been considered acceptable. FIGURE 1. Relay, outline drawing - Continued. Provided by IHSNot for ResaleNo reproducti
10、on or networking permitted without license from IHS-,-,-MIL-PRF-6106/12F 4 REQUIREMENTS: Coil data: See table I. Rated contact load: See table II. Dimensions and configuration: See figure 1. Weight: 0.18 pound (81.64 grams) maximum. Temperature range 1/: -70C to +125C. Maximum altitude rating: 300,0
11、00 feet. Shock G-level: 200 g. Duration: 6 ms. Maximum duration contact opening: 10 s. Vibration-sinusoidal: 0.12 inch DA, 10 Hz - 70 Hz. 30 g, 70 Hz - 3,000 Hz. Vibration (random): Applicable specification: MIL-STD-202, method 214, test condition IG. Duration: 15 minutes, each plane. Acceleration:
12、15 gs Strength of terminals and mounting studs: Applicable. Terminal solderability: Applicable to solder pin and solder hook terminals only. Insulation resistance, initial: 100 megohms. After life or environmental tests: 50 megohms. 1/ For full rated load at maximum temperature and altitude, use no.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILPRF610612F2011RELAYELECTROMAGNETICTYPEIMAGNETICLATCH25AMPERES3PNOMAINCONTACTSWITH2AMPERE1PDTAUXILIARYCONTACTSHERMETICALLYSEALEDPDF

链接地址:http://www.mydoc123.com/p-692974.html