1、 Comments, suggestions or questions on this document should be addressed to DLA Land and Maritime, ATTN: VAT, Post Office Box 3990, Columbus, OH 43218-3990, or emailed to mailto:Relaydla.mil. Since contact information can change, you may want to verify the currency of this address information using
2、the ASSIST Online database at https:/assist.dla.mil. AMSC N/A FSC 5945 MIL-PRF-28776E 10 September 2012 SUPERSEDING MIL-PRF-28776D 1 November 2002 PERFORMANCE SPECIFICATION RELAYS, HYBRID, ESTABLISHED RELIABILITY, GENERAL SPECIFICATION FOR This specification is approved for use by all Departments an
3、d Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification establishes the general requirements for relays that use a combination of solid state circuit input elements functioning with an electro-mechanical relay that performs the switching functions associated with control syst
4、em applications (see 6.1). These relays are designed to operate in low and medium power switching circuits with contact ratings up to 1 ampere alternating current (ac) or direct current (dc). The failure rate level is established at a confidence level of 90 percent for qualification and 60 percent f
5、or maintenance of qualification based on 100,000 cycles at +125C under rated load conditions specified herein. Excludes time delay relays. CAUTION: The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. CAUTION: Pick-up, hold, and dropout voltages ar
6、e for test purposes only and are not to be used as design criteria. For additional application and caution information, see 6.1. 1.2 Part or Identifying Number (PIN). The PIN consists of the letter “M“, the basic number of the specification sheet, an assigned dash number (see 3.1), and a suffix lett
7、er designating failure rate level (see table I) as shown in the following example: M 28776 -001 L | | | |_ M prefix Specification Dash Failure designator sheet numb number rate level 1.3 Failure rate (FR) level designation. The failure rate level designation is shown in table I (see 4.6). TABLE I. F
8、ailure rate level designation. Failure rate level designation Failure rate level (percent per 10,000 cycles) L M P R 3.0 1.0 0.1 0.01 INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-28776E 2 2. APPLICABLE DOCUMENTS 2.1 General. The
9、 documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of th
10、is list, document users are cautioned that they must meet all specified requirements of documents cited in sections 3 and 4 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and ha
11、ndbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATIONS (See supplement 1 for list of associated specifications.) DEPARTMENT OF DEFENSE STANDAR
12、DS MIL-STD-202 - Electronic and Electrical Component Parts. MIL-STD-690 - Failure Rate Sampling Plans and Procedures. MIL-STD-750-1 - Environmental Test Methods for Semiconductor Devices Part 1: Test Methods 1000 through 1999. MIL-STD-790 - Established Reliability and High Reliability Qualified Prod
13、ucts List (QPL) Systems for Electrical, Electronic and Fiber Optic Parts Specifications. MIL-STD-883 - Microcircuits. MIL-STD-1276 - Leads for Electronic Component Parts. MIL-STD-1285 - Marking of Electrical and Electronic Parts. MIL-STD-1686 - Electrostatic Discharge Control Program for Protection
14、of Electrical and Electronic Parts. Assemblies and Equipment (Excluding Electrically Initiated Explosive Devices). DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-263 - Electrostatic Discharge Control Handbook for Protection of Electrical and Electronic Parts, Assemblies and Equipment (Excluding Electrical
15、ly Initiated Explosive Devices) (Metric). MIL-HDBK-338 - Electronic Reliability Design. (Copies of these documents are available online at https:/assist.dla.mil/quicksearch/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.3 Non-Govern
16、ment publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) ASTM B488 - Electrodeposited Coatings o
17、f Gold for Engineering Uses. (Copies of this document are available from the American Society for Testing and Materials, 100 Barr Harbor Drive, West Conshohocken, PA 19482-2959 or http:/www.astm.org.) INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS IEEE 315 - Graphic Symbols for Electric and Elect
18、ronic Diagrams (Including Reference Designation Letters) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-28776E 3 (Copies of this document are available from http:/www.ieee.org/ or Institute of Electrical and Electronics Engineers (IEEE) Serv
19、ice Center, 445 Hoes Lane, P. O. Box 1331, Piscataway, NJ 08855-1331. TECHAMERICA EIA-557 - Statistical Process Control Systems. (Copies of this document are available from http:/www.techamerica.org/ or TechAmerica, 601 Pennsylvania Ave., NW, North Building, Ste. 600, Washington DC, 20004-2650.) 2.4
20、 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this document and the references cited herein (except for related specification sheets), the text of this document takes precedence. Nothing in this document, however, supersedes ap
21、plicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Specification sheets. The individual item requirements shall be as specified herein and in accordance with the applicable specification sheet. In the event of any conflict between requirements of this sp
22、ecification and the specification sheet, the latter shall govern. 3.2 Qualification. Relays furnished under this specification shall be products which are authorized by the qualifying activity for listing on the applicable qualified products list (QPL) at the time of award of contract (see 4.4 and 6
23、.3). 3.3 Reliability and Statistical process control (SPC). 3.3.1 Reliability. Reliability of relays furnished under this specification shall be established and maintained in accordance with the requirements and procedures specified in MIL-STD-790 and MIL-STD-690 with details and exceptions specifie
24、d in 4.2, 4.4.4, and 4.5. 3.3.2 Statistical process control (SPC). The contractor shall implement and use SPC techniques in the manufacturing process for parts covered by this specification. The SPC program shall be developed and maintained in accordance with EIA-557. The SPC program shall be docume
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILPRF28776E2012RELAYSHYBRIDESTABLISHEDRELIABILITYGENERALSPECIFICATIONFORPDF

链接地址:http://www.mydoc123.com/p-692808.html