DLA MIL-PRF-24623 7 A-2013 SPLICE MECHANICAL SIMPLEX FIBER OPTIC CABLE AIRCRAFT.pdf
《DLA MIL-PRF-24623 7 A-2013 SPLICE MECHANICAL SIMPLEX FIBER OPTIC CABLE AIRCRAFT.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-PRF-24623 7 A-2013 SPLICE MECHANICAL SIMPLEX FIBER OPTIC CABLE AIRCRAFT.pdf(17页珍藏版)》请在麦多课文档分享上搜索。
1、 MIL-PRF-24623/7A 03 July 2013 SUPERSEDING MIL-PRF-24623/7 27 August 2010 PERFORMANCE SPECIFICATION SHEET SPLICE, MECHANICAL, SIMPLEX FIBER OPTIC CABLE, AIRCRAFT This specification is approved for use by all Departments and Agencies of the Department of Defense The requirements for acquiring the pro
2、duct described herein shall consist of this specification sheet and MIL-PRF-24623. SCOPE: The performance requirements specified herein cover mechanical splices suitable for military aircraft use with single fiber (simplex) optical cables containing either multimode or single mode optical fibers. EN
3、VELOPE DIMENSIONS Designation Description Dimension (max) (mm) (inch) D1 maximum diameter of strain relief capture mechanism section 4/ 4/ D2 maximum diameter of barrel (body) section 7.0 0.28 D3 maximum diameter of barrel section with heat shrink applied 8.0 0.31 L1 maximum length of barrel (body)
4、section 40.0 1.59 L2 maximum length of mechanical splice (strain relief capture mechanism from one end to other end) 57.0 2.25 L3 maximum length of mechanical splice with heat shrink applied (one end of heat shrink to other end) 89.0 3.50 NOTES: 1. Dimensions are in millimeters. 2. Inch equivalents
5、are given for general information only. 3. Minimum splice length is preferred. 4. Dimension D1 is defined in terms of diameter compatibility with the crimp tool (see “Cable strain relief capture mechanism”). 5. Maximum dimension of heat shrink specified is before shrinkage. Length of heat shrink pro
6、vided (before shrinkage) shall not be less than 70 mm (2.75 in). FIGURE 1. Mechanical splice, single fiber cable, aircraft. AMSC N/A FSC 6060 METRIC Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-24623/7A 2 Part or identifying number (PIN):
7、See table I and 6.6 of MIL-PRF-24623. M 24623 /7 -XXXX Prefix Basic Specification SICC code specification sheet (see table I) TABLE I. Splice Identification Color Coding (SICC) numbers and insertion loss for specified optical fiber sizes. Fiber size (core/cladding) microns (um) SICC Insertion loss 1
8、/ Style 1 Style 2 Initial (dB) Verification (dB) 3/ Single mode 99 percent pure) isopropyl alcohol prior to the test. Prepare the salt solution as specified in 8.1 of ASTM B117 ensuring proper pH (see 8.2 of ASTM B117). Purity shall be greater than 99 percent of SO2gas in cylinder. Verify that test
9、samples are suspended in the chamber at an angle from 6oto 45ofrom the vertical. Operate the modified SO2/salt spray (fog) chamber with a constant salt spray introducing SO2gas for 1 hour four times a day (every 6 hours in accordance with A.4.4.4.1 of ASTM G85). Test duration (exposure period) shall
10、 be 336 hours. Introduce the SO2gas at a flow rate of 1 cubic centimeter per minute per cubic foot (cm3/min-ft3) (35 cubic centimeters per minute per cubic meter (cm3/min-m3) of cabinet volume using a method to ensure uniform dispersion throughout the chamber interior (such as gas dispersion ring).
11、Measure the salt spray (fog) fallout rate at intervals of every 24 hours and ensure fallout has specified pH (2.5 to 3.2) and a rate of 1 to 3 ml/80cm2/hr. After the exposure period, remove the test samples from the chamber. Clean test samples by gently washing or dipping in running tap water (not w
12、armer than 38o C (100o F) for at least 5 minutes. Dry immediately with a stream of clean, dry compressed air or inert gas. Once cleaned and dried, the assemblies shall be examined under three-power magnification for modified SO2/salt penetration into the connector junction area and damage to externa
13、l parts. Adequate safety measures must be taken during this test. Fallout rate measurements and otherwise opening of the chamber shall not occur during an SO2cycle (dispersion period). Once the chamber is opened, sufficient time must be allotted for exhaust hood or other means of ventilation to remo
14、ve the SO2atmosphere prior to exposure to the chamber interior. No visible evidence of modified SO2/salt penetration into the mechanical splice sealed area shall be observed. No corrosive effects shall be seen on the external parts (including barrel and strain relief capture mechanism) which would b
15、e detrimental to the operation of the mechanical splice. Insertion loss verification requirement shall be met. Fluid immersion. Applicable except that specimens (each mechanical splice (cable assembly) and each sample of polymeric material) shall be exposed to the all of the fluids at the temperatur
16、es specified in table 3409-AI, Measurement 3409 of MIL-STD-1678-3 for temperature range 2. Specimens shall be maintained at ambient conditions for a minimum of 4 hours prior to fluid testing. After immersion, all specimens shall be drained (for at least 10 minutes), blotted to Provided by IHSNot for
17、 ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-24623/7A 12 remove excess fluid (without scrubbing or mechanically interact), rinsed with moderate agitation (using only a back and forth or up and down type motion) for a maximum of 30 seconds in isopropyl alcohol (
18、TT-I-735), blotted dry (without scrubbing or mechanically interact), and air dried for a minimum of one hour prior to inspection and transfer to subsequent fluid. Prior to and after testing, the mechanical splice shall be visually examined and the separate polymeric samples shall be visually and dim
19、ensionally examined. Flammability. Test samples (mechanical splices on single fiber cable) shall be tested in accordance with EIA-364-81 and as specified herein. Test samples shall be exposed to a 19 mm (.75 inch) flame height applied for ten seconds to the region of the fiber-to-fiber interface. Th
20、e change in optical transmittance shall be measured during the test and after the test once the test sample has returned to room temperature. The test samples shall then be exposed to a 38.1 mm (1.50 inch) flame height applied for 60 seconds to the mechanical splice-cable interface region. Environme
21、ntal performance. The environmental tests in table II shall be performed in the sequence listed. The environmental tests shall be performed per the applicable TIA-455 series or otherwise cited test standards with the exception of adhering strictly to any deviations, constraints or augmentations in t
22、he applicable 3300 series Measurements in MIL-STD-1678-3. Post exposure optical transmittance measurements may be taken up to 24 hours after completion of the environmental exposure. Thermal shock. Test samples (mechanical splices in single fiber cable) shall be tested in accordance with TIA/EIA-455
23、-71, schedule C-0 (5 cycles). The mechanical splices shall be visually examined after the test. Mechanical splices shall not be damaged, and there shall be no loosening of parts, leaking of index matching fluid, or other damage detrimental to the operation of the mechanical splice. Types 1 and 2 cab
24、les. The temperatures of -55C +0 -5C and 165C +5/-0C shall be used for the low and high soak temperatures, respectively. The change in optical transmittance shall be measured during (towards the end of each soak temperature) and after the test. The requirement for the change in optical transmittance
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILPRF246237A2013SPLICEMECHANICALSIMPLEXFIBEROPTICCABLEAIRCRAFTPDF

链接地址:http://www.mydoc123.com/p-692641.html