DLA MIL-PRF-15160 K-2013 FUSES INSTRUMENT POWER AND TELEPHONE GENERAL SPECIFICATION FOR.pdf
《DLA MIL-PRF-15160 K-2013 FUSES INSTRUMENT POWER AND TELEPHONE GENERAL SPECIFICATION FOR.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-PRF-15160 K-2013 FUSES INSTRUMENT POWER AND TELEPHONE GENERAL SPECIFICATION FOR.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、INCH-POUND MIL-PRF-15160K 19 January 2013 SUPERSEDING MIL-PRF-15160J 15 May 2006 PERFORMANCE SPECIFICATION FUSES, INSTRUMENT, POWER, AND TELEPHONE GENERAL SPECIFICATION FOR This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This s
2、pecification covers the general requirements and test procedures for nonrenewable instrument, power, and telephone fuses for the protection of electrical and electronic equipment. 1.2 Classification. 1.2.1 Part or Identifying Number (PIN). The PIN designation is in the following form and as specifie
3、d (see 3.1 and 6.2). F02 A 250 V 1 1/2 A S Style Characteristic Voltage Current Silver plated (1.2.1.1) (1.2.1.2) rating rating (1.2.1.5) (1.2.1.3) (1.2.1.4) 1.2.1.1 Style. The style is identified by the letter “F” followed by a two-digit number denoting a fuse of a given interface and physical dime
4、nsion. 1.2.1.2 Characteristics. The characteristics are identified by a one-letter or two-letter symbol which indicates the relative overload interrupt time (see 6.7) and other special features in accordance with table I. 1.2.1.3 Voltage rating. The voltage rating is the maximum direct current (dc)
5、or alternating current (ac) root mean square (rms) voltage for which a fuse is designed. The voltage rating is identified by a numerical value followed by the letter “V”. The voltage rating is as specified (see 3.1 and 6.2). 1.2.1.4 Current rating. The current rating is the amount of current a fuse
6、will carry indefinitely without interruption. The current rating in amperes is identified by a numerical value followed by the letter “A”. The current rating is as specified (see 3.1 and 6.2). 1.2.1.5 Silver plating. The letter “S” identifies fuses which have silver-plated terminals (see 3.5.4 and 6
7、.2). Identification of other platings is not required. Comments, suggestions, or questions on this document should be addressed to: DLA Land and Maritime ATTN: DLA Land and Maritime-VAT, Post Office Box 3990, Columbus, Ohio 43218-3990 or emailed to CircuitProtectdla.mil. Since contact information ca
8、n change, you may want to verify the currency of this address information using the ASSIST Online database at https:/assist.dla.mil. AMSC N/A FSC 5920Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-15160K 2 TABLE I. Relative overload interrup
9、t time. Symbol Relative overload interrupt time A B BR C Normal opening - normal interrupting capacity Time delay - normal interrupting capacity Time delay - very high interrupting capacity, reject feature Normal opening - very high interrupting capacity 2. APPLICABLE DOCUMENTS 2.1 General. The docu
10、ments listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this li
11、st, document users are cautioned that they must meet all specified requirements of documents cited in sections 3 and 4 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handboo
12、ks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract (see 6.2). COMMERCIAL ITEM DESCRIPTIONS A-A-59544 - Cable and Wire, Electrical (Power, Fixed Installation). DEPARTMENT OF DEFENSE
13、SPECIFICATIONS MIL-PRF-19207 - Fuseholders, Extractor Post Type, Blown Fuse, Indicating and Nonindicating, General Specification for. (See supplement 1 for list of associated specification sheets.) DEPARTMENT OF DEFENSE STANDARDS MIL-STD-202 - Test Methods for Electronic and Electrical Component Par
14、ts. MIL-STD-1285 - Marking of Electrical and Electronic Parts. (Copies of these documents are available online at https:/assist.dla.mil/quicksearch/ or https:/assist.dla.mil or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094). 2.3 Non-Govern
15、ment publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract (see 6.2). Provided by IHSNot for ResaleNo reproduction or networking permitted without li
16、cense from IHS-,-,-MIL-PRF-15160K 3 INTERNATIONAL ORGANIZATION FOR STANDARDS (ISO) ISO 10012 - Measurement Management Systems - Requirements for Measurement Processes and Measuring Equipment. ISO/IEC 17025 - General Requirements for the Competence of Testing and Calibration Laboratories. (Copies of
17、these documents are available online at http:/www.iso.org/iso/home.html or from the American National Standards Institute (ANSI), 1899 L Street, NW, 11th Floor, Washington, DC 20036-3804). 2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event of conflict between the
18、 test of this document and the references cited herein (expect for related specification sheets), the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Specification
19、 sheets. The individual item requirements shall be as specified herein and in accordance with the applicable specification sheet. In the event of any conflict between the requirements of this specification and the specification sheet, the latter shall govern. 3.2 Fuses with ratings not covered by a
20、specification sheet. The requirements of this specification shall apply to fuses with other voltage and current ratings, provided the fuse has the same dimensions and falls within the minimum and maximum current and voltage rating of an existing specification sheet, and conforms to all other require
21、ments of that specification sheet. The Qualified Products List (QPL) shall be applicable to these fuses. 3.3 Qualification. Fuses furnished under this specification shall be products that are authorized by the qualifying activity for listing on the applicable qualified products list before award of
22、contract (see 4.4 and 6.5). 3.4 Material. The material for each part shall be as specified herein. However, when a definite material is not specified, a material shall be used which will enable the fuses to meet the performance requirements of this specification. Acceptance or approval of any consti
23、tuent material shall not be construed as a guaranty of the acceptance of the finished product. 3.4.1 Recovered materials. Unless otherwise specified herein, all equipment, material, and articles incorporated in the products covered by this specification shall be new and may be fabricated using mater
24、ials produced from recovered materials to the maximum extent practicable without jeopardizing the intended use. The term “recovered materials“ means materials which have been collected or recovered from solid waste and reprocessed to become source of raw materials, as opposed to virgin raw materials
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILPRF15160K2013FUSESINSTRUMENTPOWERANDTELEPHONEGENERALSPECIFICATIONFORPDF

链接地址:http://www.mydoc123.com/p-692217.html