DLA MIL-PRF-1 868 F-2008 ELECTRON TUBE NEGATIVE GRID (MICROWAVE) TYPE 2C40A.pdf
《DLA MIL-PRF-1 868 F-2008 ELECTRON TUBE NEGATIVE GRID (MICROWAVE) TYPE 2C40A.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-PRF-1 868 F-2008 ELECTRON TUBE NEGATIVE GRID (MICROWAVE) TYPE 2C40A.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、AMSC N/A FSC 5960 INCH-POUND MIL-PRF-1/868F 18 June 2008 SUPERSEDING MIL-E-1/868E 17 March 1977 PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, NEGATIVE GRID (MICROWAVE) TYPE 2C40A This specification is approved for use by all Depart- ments and Agencies of the Department of Defense. The requirements
2、for acquiring the electron tube described herein shall consist of this document and MIL-PRF-1. DESCRIPTION: Planar triode, metal-glass. See figure 1. Mounting position: Any. Weight: 1.2 ounces (34 grams) nominal. ABSOLUTE RATINGS: CW OSCILLATOR Parameter: F Ef Eb Ib Ehk Ik Pp tk T(seal) Ec Ic Unit:
3、MHz V V mA dc V mA dc W sec C V dc mA dc Maximum: 3,370 6.6 500 25 90 33 6.5 - 200 -50 8.0 Minimum: - 6.0 - - - - - 60 - - - ANODE PULSED OSCILLATOR Parameter: F Ef eb ec Ehk Ib ib Ic ic Pp tp Du T(seal) Unit: MHz V v v V mA dc a mA dc a W s - C Maximum: 3,370 6.6 1,400 -100 90 3.0 2.0 1.5 1.0 4.0 1
4、.5 0.002 200 Minimum: - 6.0 - - - - - - - - - - - TEST CONDITIONS Parameter: Ef Eb Ck Rk tk Unit: V V F Ohms sec 6.3 250 1,000 200 300 GENERAL: Qualification Required. Holding period (MIL-STD-1311) t = 168 hours. - See note 1/. Inactive for new design after 21 July 1997 Provided by IHSNot for Resale
5、No reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/868F 2TABLE I. Testing and Inspection Limits Inspection Method MIL-STD-1311 Conditions Acceptance level note 8 Symbol Min Max Unit Conformance inspection, part 1 Pulse emission 1231 prr = 500; tp = 2.0 s; (eb=ec)/is = 2.5
6、 a 0.65 etd - 190 V Total grid current 1266 0.65 Ic - -0.5 A dc Power oscillation (pulsed) 1236 Rk = Rg = 0; eb = 1,400 v; tp = 1.0 s 10%; prr = 1,000 10%; Du = 0.001 10%; F = 3,000 MHz (min); ib = 1.5 a (max); t = 30 sec (min) see notes 2,3 and Dwg 209-JAN 0.65 Po starting voltage 200 - mW Transcon
7、ductance 1306 0.65 Sm 4,400 5,700 mhos Electrode current (anode) 1256 0.65 Ib 12 21 mA dc Conformance inspection, part 2 Insulation of electrodes 1211 E(g to all)= -100 V dc E(sh to all)=-500 V dc - R 100 - Meg Heater current 1301 - If 700 800 mA dc Electrode voltage (cutoff) (grid) 1261 Ec/Ib = 10
8、Adc - Eco - -26 V dc Heater-cathode leakage 1336 - Ihk - 50 A dc Power oscillation (cw) 1236 Eb = 250 V dc (max); Ib = 25 mA dc (max); Rg = 10,000 ohms; Rk = 0; F = 3,370 100 MHz; t = 30 sec (min) Dwg 102-JAN - Po 35 - mWDirect-interelectrode capacitance 1331 No voltages DESC Dwg 65025 - Cgp Cin Cou
9、t Cksh 1.20 2.00 - 50 1.40 2.45 0.030 200 pF pF pF pF Emission 1231 (Eb=Ec)/Is = 40 mA dc - Etd - 8 V dc Amplification factor 1316 - Mu 27 44 - Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/868F 3TABLE I. Testing and Inspection Continued
10、Limits Inspection Method MIL-STD-1311 Conditions Acceptance level note 8 Symbol Min Max Unit Conformance inspection, part 3 Life-test (1) - Group A Eb = 300 Vdc; Rk/Ib = 17 mAdc; t = 500 hours - - - - - Life-test (1) end point: - Power oscillation (cw) 1236 - Po 25 - mW Life-test (2) - Group C; powe
11、r oscillation (pulsed) except prr = 2,000 10% t = 500 hours - - - - - Life-test (2) end point - Life-test (2) conditions - Po 300 - mW High-frequency vibration 1031 F = 50 Hz; 10G; Ebb = 300 V dc; Rp = 10,000 ohms; Ec/Ib = 10 mA dc Notes 4, 5 and 7 - Ep - 100 mV Secureness of base, cap, or insert 11
12、01 No voltages; torque to be applied between anode and pins without shock Notes 4 and 7 - - 20 - lb-in Torque-test end point - Total grid current 1266 Note 7 - Ic - -0.5 A dc Frequency draft - Notes 4, 6 and 7 - F - 2.0 MHz NOTES: 1. The following test methods shall not apply: MIL-STD-1311 Methods 1
13、006 and 1201. 2. The pulse shape shall be in accordance with method 1296. Minimum power output limit, based on a duty factor of 0.001, may be adjusted for the exact duty factor used. Coupling and tuning to be adjusted for maximum power output. The tube shall operate under the given conditions and mi
14、nimum output, or greater, for a minimum of 30 seconds without arcing or instability as evidenced by pronounced variations in the average anode current meter or the power output meter. If temporary arcing does occur during the 30-second period, the tube must subsequently operate for 60 seconds withou
15、t arcing. The test may be discontinued, at the end of the 30-second period, if the power output has not completely stabilized but is rising. If the power output is falling, the test is continued until a stable reading is obtained. For qualification approval, a stable reading shall be obtained. 3. Th
16、e starting voltage is measured by raising the pulsed anode voltage from zero and noting the voltage at which a readable indication is obtained on the power meter. The tube may not be oscillating during the full width of the modulation pulse during this test. 4. Test 10 tubes selected at random from
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILPRF1868F2008ELECTRONTUBENEGATIVEGRIDMICROWAVETYPE2C40APDF

链接地址:http://www.mydoc123.com/p-692108.html