DLA MIL-PRF-1 849G-1998 ELECTRON TUBE MAGNETRON TYPE 6543《电子管磁控型6543》.pdf
《DLA MIL-PRF-1 849G-1998 ELECTRON TUBE MAGNETRON TYPE 6543《电子管磁控型6543》.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-PRF-1 849G-1998 ELECTRON TUBE MAGNETRON TYPE 6543《电子管磁控型6543》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、 MIL-PRF-L/849G 999990b 20bLqLb 126 Parameter: Ef if(surge) k tPc ib Pi a kw Unit: V a SBC cis Maximum 13.7 lo - 3.3 16.0 250 Minimum _I_ .- 120 I 14.0 - I INCH-POUND I MIL-PRF-lB49G 11 March 1998 SUPERSEDING 20 February 1976 MIL-E-11849F Pi VSWR W - 250 151 - -. PERFORMANCE SPECIFICATION SHEET ELEC
2、TRON TUBE, MAGNETRON TYPE 6543 Parameter: Unit: Maximum Minimum This specification is approved for use by all Depart- ments and Agencies of the Department of Defense. The requirements for acquiring the electron tube described herein shall consist of this document and the latest issue of MIL-PRF-I. T
3、uner drive toque T (anode) T (input bushing) Altitude in.oz “C “C R 50 150 175 10,000 - -65 -65 - DESCRIPTION: Pulsed, tunable frequency range 8,500 to 9,600 MHz, rated peak power ouiput 65 kw. integral magnet. ABSOLUTE RATINGS: Dimensions: See figure 1 Cathode: Mounting support: Mounting Range Magn
4、et: Weight: Mounting position: hY Marking: GI Handling: Unipotential 6 pounds 2 ounces (approx) 41 - 41 ABSOLUTE RATINGS: AMSC NIA 1 Of 14 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. FSC 5960 Provided by IHSNot for ResaleNo reproduction or networking permitted w
5、ithout license from IHS-,-,- MIL-PRF-L/49G = 99999Ob 2ObLl17 Ob2 Parameter: Unit: Maximum Min i m u m Ef V - 10.4 _- MIL-PRF-11849G Parameter: Ef tpc mr Du Ib kVIps _- mA dc Unit: V PS Maximum 3.30 _- _ _- 7.8 _ -_-_ 0.001 15.0 Minimum -. 3.10 120 21 -_- F1 = 8.500 MHz F2 = 8.600 MHz F3 = 9.000 MHz
6、F4 = 9,375 MHz F5 = 9,600 MHz VSWR -_ 1.10 - I 0.40 _ 0.35 mr kVlps GENERAL: Qualification - Required. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-118496 TABLE I. Testinq and insoection. No voltage applied; 15G; I= 11 ms No voltages app
7、lied No vdtages applied Inspection Qualification insoection vibration /anable-1 requency Shock, specified pulse TA = 25C F = 9,550 i 50 MHz runer stop endurance Mechanical tuning fatigue T (ande) = 70“ i 10C F=FltOF5 Ib = 4.0 and 5.0 mA dc Ib = 13.5 and 16.5 mA dc Ib = 4.0 and 5.0 mA dc F = F1, F3,
8、F5 F = F1 to F5; 3perating torque or force Resetiability Direct-interelectrode capacitance Tuning rate RF bandwidth Minor lobe ratio Mechanical tuning rate Barometric pressure, Temperature coefficient reduced Low-temperature Forced cooling operation Conforniance insDection. Pressurizing Heater curen
9、t Operating toque or force Mechanical tuning range jee footnotes at end of tab16 - 1031 1042 4223 4223 4223 4223 4266 4223 4308 4308 4223 4028 4027 1047 1143 - 4003 4289 4223 4223 - Conditions VCWR = 1.5:l; pressure T(anode) = 70“ to 100C; F=F3 tk = 120 s8c (max); F=F3 = 500 mHg (absdute) 40 to 45 p
10、sia, input and output assemblies (max) Ef = 12.6v tk= 120- TA = 25 f 5% T(anode) = 70“ i 10C Upper limit Lower limit $mtld - I rorque .- roque AF C AF BW BW Ratio - .- A FIAT MP T - If Toque F F - Unit - - - in.-az Cycles in. oz MHz PF MHz MHz MHz dB - -_ MWC % %(rise I- A in.oz MHz MHz 3 Provided b
11、y IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- UIL-PRF-L/84G Ob 20bLL9 335 = MIL-PRF-1l849G TABLE I. Testinq and inspection. Inspection Conformance inwection, - Continued RF bandwidth Minor lobe ratio Stability Starting stability Pulse voltage Power output I
12、 Conformance incoection, Dart2 Variable-frequency vibration Operating torque or force Resettability Frequency pulling figure Power output Heater-voltage sensitivity Conformance inspection, Life test Life-tests end points: Power output RF bandwidth Minor lobe ratio Stability Resettability See notes a
13、t end of table. Method 4308 4308 431 5 431 5 4306 4250 1031 4223 4223 4310 4250 -_ -_ 4250 4308 4308 431 5 4223 Notes _- 151 161 211 - _ 151 231 - 5/21/23 -. 1 2 1 1,2 2 2 2 Conditions F = F1 to F5 F = F1 to F5 F = F1 to F5 F= Fl F = F5 t = 300 (max); F = F1, F3, F5 No voltages applied TA = -50C TA
14、= +125“C; no voltages applied F = 9,550 f 50 MHz F = F1 to F5. in 100 MHz increments F= F1 to F5 Group C; VSWR = 1.5:l (min) Symbol BW BW Ratio MP MP ePY Po Torque Toque AF AF Po _- -_ t Po BW Ratio MP AF L Ma P.O/tpc 3.Oitpc 1 .o 1 .o 16.5 _ Unit MHz MHz dB Ye % kv W _- in.-oz in.-oz MHz MHz W _ -
15、Sycles hrs w MHz dB % MHz - 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/8llG 9Ob 20bL20 b57 TABLE I. Testina and inspection - Continued. - 1/ Unless otherwise specified, the acceptance level for all tests listed under conformance insp
16、ection, part 1. shall be 1 .O, inspection level II. - 2/ 10 to 55 to 10 Hz. Vibrate from 1 to 3 minutes at 10 G or 0.60-inch (1.53 mm) double amplitude; repeat for a total of 90 minutes in each of the three muhially perpendicular axes. Vibrate for 30 minutes at each of the resonant frequencies noted
17、. - 31 VSWR cycled through kg in about 30 minutes: starting at 8,500 MHz, the frequency shall be increased in 100 MHz increments every 10 hours. - 4/ In handling and mounting the magnetron, care shall be exercised to prevent demagnetization. - 5. Immediately after a nonoperating period of 168 hours
18、minimum, the starting stability test shall be performed on 100 percent of the submitted lot. - 6/ After subjection to the specified test, the tube shall meet the requirements for RF bandwidth, minor lobe ratio, and stability as specified under test condition 1. - 7. Separate samples shall be require
19、d for this test. &/ The tubes shall be fastened rigidly to the vibration plaform and vibrated with simple harmonic motion. The direction of vibration shall be as indicated on figure 1. - 9/ The tuning mechanism shall withstand the specified toque at the limits of mechanical motion. - 1 O/ The toque
20、required to operate the tuning shaft through the specified tuning range shall not exceed the maximum specified. - 1 1 I The tuner shall operate for at least the specified number of cycles. The tube shall then meet all of the conditions of test condition 2 and the toque and backlash at room temperatu
21、re shall not exceed the specified amount. One cycle is defined as a complete traverse from one end of the tuning range to the other and back again. During this test the tuner may be lubricated not more than once every 1,000 cycles with Texaco low-temperature grease No. 1,888, or equivalent. - 12/ Al
22、ter the specified number of cycles, the tube shall pass all the tests under test condition 2 in conformance inspection, pari 1. - 13/ The frequency obtained by tuming the tuner to a given setting in one direction shall be reproducible within specified limits when returning to that same setting from
23、the opposite direction after thermal equilibrium. - 14/ After thermal frequency stability has been reached at each of the frequencies of this test, F1, F2, F3, F4, F5 (see Lq, the cum of frequency versus tuner position shall not deviate more than the specified amount from the curve on figure 2. - 15
24、1 This test shall be perfomed by a continuous observation while the tube frequency and a stub having a VSWR of 1.5:1 minimum are continuously varying. The stub shall travel a minimum of 180 electrical degrees for every 20 MHz of magnetron tuning. - 16/ The measurement shall be made throughout the sp
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILPRF1849G1998ELECTRONTUBEMAGNETRONTYPE6543 电子管 磁控型 6543 PDF

链接地址:http://www.mydoc123.com/p-692103.html