DLA MIL-PRF-1 1388 G-2013 ELECTRON TUBE RADIATION COUNTER TYPE 7840.pdf
《DLA MIL-PRF-1 1388 G-2013 ELECTRON TUBE RADIATION COUNTER TYPE 7840.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-PRF-1 1388 G-2013 ELECTRON TUBE RADIATION COUNTER TYPE 7840.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、INCH-POUND MIL-PRF-1/1388G 11 September 2013 SUPERSEDING MIL-PRF-1/1388F 15 August 2012 PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, RADIATION COUNTER TYPE 7840 This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the e
2、lectron tube described herein shall consist of this document and the latest issue of MIL-PRF-1. DESCRIPTION: Thin end mica window, self-quenched counter tube for detection of low intensity beta radiation. See figure 1. Mounting position: Any. Weight: 7 ounces (198.5 grams) nominal. ABSOLUTE RATINGS:
3、 Parameter: Ebb TA Rp Mica window thickness Unit: V dc C Meg mg/cm2 Maximum: 1,600 40 - 2.2 Minimum: 1,300 0 1 1.8 Test conditions: 1,400 - 1 - See footnotes at end of table I. _ GENERAL: Qualification - Required. Holding period (MIL-STD-1311) - 60 days. Window test - 13/ Shelf life - Required (see
4、conformance inspection, part 1). Acceptance test - Required. 15/ Service-life guarantee (MIL-PRF-1) - With qualifying activity approval manufacturer may provide service-life guarantee, in lieu of life test. Guaranteed tube operating time shall be 250 hours minimum. Marking - Tubes sold under service
5、-life guarantee shall be marked with contract number and with the number of tube operating hours (250 hrs min) guaranteed. This specification sheet uses accept on zero defect sampling in accordance with MIL-PRF-1, table III. AMSC N/A FSC 5960 Provided by IHSNot for ResaleNo reproduction or networkin
6、g permitted without license from IHS-,-,-MIL-PRF-1/1388G 2 TABLE I. Testing and inspection. Inspection Method Notes Conditions Symbol Limits Unit MIL-STD-1311 Min Max Conformance inspection, part 1 Background, contamination and photosensitivity 6201 2/ 6/ 12/ 17/ t = 4 minutes (min) N/t - 20 Npm Sta
7、rting voltage 6211 5/ 12/ 18/ 19/ Pulse amplitude = 0.50 V; Nps = 100 (min); R2 = 1 Meg 10%; R1 = C1 = C2 = 0; C3 = 0.01 F 10% Es - 1,250 V dc End-of-plateau voltage 6216 - Ps = 3%/100 V dc Ee 1,650 - V dc Relative plateau slope 6216 15/ Voltage range = 1,300 to 1,600 V dc Ps - 3 %/100 V dc Backgrou
8、nd, contamination and photosensitivity 6201 2/ 6/ 12/ 17/ t = 4 minutes (min) N/t - 20 Npm Response count rate and current (beta) 6221 3/ 6/ 12/ Ebb = 1,400 V dc; counting time = 2 minutes (min) N/t 3/ - Npm Shelf life - 14/ - - - - Conformance inspection, part 2 Leakage current 6205 - Ebb = 700 Lib
9、 - 0.5 A dc Shock 1041 1/ 11/ 20/ 450 G - - - - Response count rate and current (hysteresis (1a) 6221 6/ 7/ 8/ Ebb = 1,400 V dc; t = 2 minutes (min); record count rate values - - - - Response count rate and current (hysteresis (1b) 6221 6/ 8/ Ebb = 1,400 V dc; t = 15 minutes (min) - - - - Response c
10、ount rate and current (hysteresis (1c) 6221 6/ 8/ Ebb = 1,400 V dc; t = 2 minutes (min); from reading taken from count rate (1a) N/t - 20 % Response count rate and current (gamma) 6221 6/ 9/ 12/ Ebb = 1,400 V dc; counting time = 2 minutes (min) N/t - 110 Npm See footnotes at end of table. Provided b
11、y IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/1388G 3 TABLE I. Testing and inspection - Continued. Inspection Method Notes Conditions Symbol Limits Unit MIL-STD-1311 Min Max Conformance inspection, part 3 Life test - Group D; Ebb = 1,400 V dc; N/t
12、= 1,000 Npm; t = 250 hours - - - - Life-test end points: Response count rate and current (beta) Response count rate and current (gamma) - 6221 6221 - - N/t N/t - - 10 10 % % Variable-frequency vibration 1031 1/ 10/ 20/ Ebb = 0 - - - - Temperature range, operating 1026 4/ N/t - 20 % Packaging - 16/ -
13、 - - - 1/ Criterion for passing this test shall be compliance after test of at least 80 percent of the tubes with the requirements for the following: (a) Starting voltage. (b) End-of-plateau voltage. (c) Relative plateau slope. (d) Response count rate and current (beta). (e) Response count rate and
14、current (gamma). 2/ The tube shall be exposed to radiation from a General Electric 4-watt germicidal lamp, Type G-4T4/1, or equivalent, with relative positions as shown on figure 2. 3/ The counting rate shall not vary by more than 0.10 N/t from the value (approximately 10,000 counts per minute (cpm)
15、 marked on the Standard Beta Reference Source (SBRS). The SBRS shall be mounted in recess of the sample positioning shelf specified with the SBRS. The proper position of this shelf for this test is specified with the SBRS. 4/ With the tube in a field giving 10,000 100 Npm at 1,400 V dc, tube respons
16、e (count rate) shall be determined at 1,300, 1,400, and 1,600 V dc at each of the following temperatures and in the order shown. (a) Room temperature. (b) 5C. (c) Room temperature. (d) 40C. (e) Room temperature. Provided by IHSNot for ResaleNo reproduction or networking permitted without license fro
17、m IHS-,-,-MIL-PRF-1/1388G 4 TABLE I. Testing and inspection - Continued. 5/ After the holding period, starting voltage shall not vary by more than 7 volts. 6/ The tube shall be mounted vertically in the lead shield (see figure 3) of the excitation unit. 7/ The tube shall have been inoperative for a
18、24-hour period prior to test. 8/ Beta reference source shall be in position as specified in 3/. 9/ Test shall be performed with the assembly shown on figure 3 in a 1.4 mr/hr Cobalt-60 radiation field (calculated). 10/ The tube shall be tested only with its longitudinal axis vertical and parallel to
19、the direction of motion. The tube shall be mounted by means of a rigid clamp at the base of the tube. 11/ The tube shall be tested only with its longitudinal axis horizontal and parallel to the direction of motion of the hammer. The tube shall be mounted by means of a rigid clamp at the base of the
20、tube. 12/ This test shall be performed at the conclusion of the holding period. 13/ All tube windows shall be tested to assure that they can withstand an internal pressure of half of an atmosphere less than ambient pressure. 14/ The shelf life requirements shall be as follows: (a) Tubes tested and a
21、cquired in accordance with this document shall be capable of a shelf life for a period of 18 months after the date of shipment from the manufacturers plant. At any time during this shelf life period the tubes shall be capable of meeting all requirements of conformance inspection, part 1, as specifie
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILPRF11388G2013ELECTRONTUBERADIATIONCOUNTERTYPE7840PDF

链接地址:http://www.mydoc123.com/p-691960.html