DLA MIL-PRF-1 1361 H-2012 ELECTRON TUBE THYRATRON TYPES 7390 AND 7390A.pdf
《DLA MIL-PRF-1 1361 H-2012 ELECTRON TUBE THYRATRON TYPES 7390 AND 7390A.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-PRF-1 1361 H-2012 ELECTRON TUBE THYRATRON TYPES 7390 AND 7390A.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、 MIL-PRF-1/1361H 12 June 2012 SUPERSEDING MIL-PRF-1/1361G 1 December 2005 PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, THYRATRON TYPES 7390 AND 7390A This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the electron tub
2、e described herein shall consist of this document and the latest issue of MIL-PRF-1. DESCRIPTION: Triode, hydrogen, ceramic-metal. See figures 1 and 1A. Mounting position: Vertical, base down. Weight: 9 pounds (4.1 kilograms) nominal. ABSOLUTE RATINGS: Parameter: Ef epy epx Ebb egy egx Ecc ib Ib Ip
3、Unit: V ac kv kv kV dc v v V dc a A dc A ac Maximum: 6.6 3.3 1/ 33 2/ - 3/ 650 - 2,000 4.0 72 Minimum: 6.0 7 5% epy 3.5 - - - - - - Test conditions: 6.3 3.3 - - 1,100 - 0 - - - ABSOLUTE RATINGS: Parameter: tj prr dikdtPb tk TA Cooling Eres Ires Unit: s - as- sec C - V ac A ac Maximum: 0.01 - 10,000
4、30x109 5/ +75 6/ 5.5 8/ 12 Minimum: - - - - 900 -55 - 3.5 - Test conditions: - 465 - - 900 - 7/ 9/ - See footnotes at end of table I. _ GENERAL: Qualification: Required. This specification sheet uses accept on zero defect sampling in accordance with MIL-PRF-1, table III. AMSC N/A FSC 5960 INCH-POUND
5、 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/1361H 2 TABLE I. Testing and inspection. Inspection Method Notes Conditions Symbol Limits Unit MIL-STD-1311 Min Max Qualification inspection Operation at elevated ambient temperature 3246 7/
6、10/ 12/ TA = 75C, except t = 5 hours egy - 1,100 v Life test (2) - 7/ 13/ 14/ epy = 25 kv; prr = 740; Ib = 4.0 A dc (min); egy = 1,200 v; Zg = 50 ohms (min); t = 500 hours - - - - Life-test (2) end points: Operation (1) DC anode voltage for conduction (1) Time jitter - 3246 3247 3261 - - - Zg = 50 o
7、hms (min) egy = 1,200 v; Zg = 50 ohms (min) egy = 1,200 v; Zg = 50 ohms (min) egy Ebb tj - - - 1,200 3,000 0.01 v V dc s Conformance inspection, part 1 Heater current (cathode) 3241 - If 22 35 A ac Heater current (reservoir) 3241 - Eres = 4.5 V ac Ires 7 10.0 A ac DC anode voltage for conduction (1)
8、 3247 15/ Eres = 105 percent of optimum value Ebb - 2,500 V dc Instantaneous starting 3267 7/ 10/ 16/ Eres = 105 percent of optimum reservoir voltage; epy = 24 kv (min) - - - - Operation (1) 3246 7/ 10/ 11/ 17/ 18/ epy = 36 kv; t = 1 hour egy - 1,100 v Operation of optimum reservoir voltage 3246 - O
9、peration (1) Eres 3.5 5.5 V ac Pulse emission (method A) 3251 20/ ik = 2,000 a; tp = 5.0 s 10 percent; prr = 60 10 percent; tr = 0.5 s (max) egk - 300 v See footnotes at end of table. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/1361H 3
10、TABLE I. Testing and inspection - Continued. Inspection Method Notes Conditions Symbol Limits Unit MIL-STD-1311 Min Max Conformance inspection, part 2 Vibration - 24/ MIL-STD-202, method 201 - - - - Shock, specified pulse 1042 4/ 24/ - - - - DC anode voltage for conduction (2) 3247 21/ Eres = 95 per
11、cent of optimum value Ebb - 2,500 V dc Operation (1A) 3246 7/ 18/ 19/ 22/ Operation (1) egy - 1,100 v Operation (2) 3246 7/ 13/ 17/ 18/ epy = 25 kv; t = 1 hour; prr = 740; Ib = 4.0 A (min) egy - 1,100 v Operation (2A) 3246 7/ 18/ 22/ Operation (2) egy - 1,100 v Anode delay time 3256 - Operation (1A)
12、; t = 2 minutes tad - 1.0 s Anode delay time drift 3256 23/ Anode delay time tad - 0.1 s Time jitter 3261 - Operation (1A), except epy = 7.0 kv; tj measured after 60 minutes of operation tj - 0.01 s Conformance inspection, part 3 Life test - 7/ 10/ 14/ Group C; epy = 1,200 v; Zg = 50 ohms (min); t =
13、 500 hours - - - - Life-test end points: Operation (1) DC anode voltage for conduction (1) Time jitter - 3246 3247 3261 - - - Zg = 50 ohms (min) egy = 1,200 v; Zg = 50 ohms (min) egy = 1,200 v; Zg = 50 ohms (min) egy Ebb tj - - - 1,200 3,000 0.01 v V dc s See footnotes at top of next page. Provided
14、by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/1361H 4 TABLE I. Testing and inspection - Continued. 1/ Instantaneous starting is not recommended. When it is necessary, the maximum permissible epy is 22 kv and it shall not be attained in less than 0
15、.04 second. 2/ In pulsed operation, the peak inverse voltage shall not exceed 5.0 kv during the first 25 s following the pulse. 3/ The driver pulse, measured at the tube socket with thyratron grid disconnected: 1,300 volts minimum; 2,500 volts maximum; tr = 0.35 s maximum; grid pulse duration 2.0 s
16、minimum. Impedance of drive circuit 10 to 25 ohms. 4/ Shock tests shall be performed in accordance with MIL-STD-202, method 213, except as noted. The tube shall be mounted on suitable rigid fixtures in the positions described below by means of its mounting flange. The tube shall not be clamped, brac
17、ed, or supported by means other than its mounting flange. The tube shall be subjected to three blows in each of the following positions: Position of tube in elevator assembly Intensity and duration of blow Vertical: Base down 80 G, 11 ms, half-sine shock pulse Horizontal: Center line through heater
18、terminals, vertical 60 G, 11 ms, half-sine shock pulse Horizontal: Center line through heater terminals, horizontal 60 G, 11 ms, half-sine shock pulse The tests shall be performed with both heater and reservoir at substantially full operation temperatures. Means for detecting heater current variatio
19、ns and shorts between anode and grid and between grid and cathode shall be provided. No temporary or permanent changes in heater or reservoir currents or temporary or permanent shorts between electrodes shall occur. 5/ Standby operation, with heater and reservoir voltage on, is not recommended. Wher
20、e standby operation is necessary, provisions shall be made to operate the tube at full equipment conditions for a minimum of 2 hours during each 12-hour period of standby. 6/ Maintain grid seal temperature within 225C above ambient temperature by blower directed at seal and lower ceramic cylinder. A
21、pproximately 15 cfm of air is required at rated power levels. 7/ Approximately 15 cfm of air may be directed at grid seal and lower envelope. 8/ The optimum reservoir voltage for operation in accordance with operation (1) conditions is inscribed on the base of the tube and must be held within 2.5 pe
22、rcent. Applications involving other operation conditions will necessitate the re-determination of the optimum reservoir voltage. 9/ Adjust reservoir voltage to value indicated on the tube within 5 percent, except as otherwise specified. 10/ The anode circuit constants shall be chosen so that at epy
23、= 33.0 kv; under resonant charging conditions; ib = 2,000a minimum; dik/dt shall be 10,000a/s minimum; tp = 2.5 10 percent s; prr = 500 minimum. Grid pulse measured at tube socket with thyratron grid disconnected: tr = 0.35 s minimum, tp = 2.0 s maximum; internal impedance of driver: 75 ohms minimum
24、. 11/ This test is to be the first test performed at the conclusion of the instantaneous starting test. 12/ The tube shall be capable of operating under the following conditions: a. Apply cathode heater voltage and adjust reservoir voltage to 95 percent of the optimum reservoir voltage and allow bot
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILPRF11361H2012ELECTRONTUBETHYRATRONTYPES7390AND7390APDF

链接地址:http://www.mydoc123.com/p-691956.html