1、 MIL-PRF-1/1232E 13 January 2012 SUPERSEDING MIL-E-1/1232D 2 July 1999 PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, GAS SWITCHING TYPE 7166 This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the electron tube describe
2、d herein shall consist of this document and the latest issue of MIL-PRF-1. DESCRIPTION: TR, frequency range 1,220 to 1,365 MHz, nominal peak power rating 1.5 Mw. ABSOLUTE RATINGS: Parameter: Unit: Incident power Mw Du - Ebb V dc Ii A dc Alt ft Maximum: Minimum: 2.0 - 0.001 - - -750 200 100 10,000 -
3、PHYSICAL CHARACTERISTICS: Dimensions: See figure 1. Mounting: See figure 2. 1/ Weight: 9 pounds (approximate). TEST CONDITIONS: Parameter: Unit: Incident power Mw tp1 s tp2 s prr pps Ii A dc F MHz Frequency Tolerance: 5% 0.15 0.15 - - - F MHz Test condition 1: Test condition 2: 0.50 2.00 4.0 4.0 1.0
4、 - 250 250 100 100 F3 F3 1 2 3 4 5 1,220 1,255 1,292 1,325 1,365 1% 1% 1% 1% 1% See footnotes at end of table I. GENERAL: Qualification: Not required Preproduction sample approval: Required. 2/ This specification sheet uses accept on zero defect sampling in accordance with MIL-PRF-1, table III. AMSC
5、 N/A FSC 5960 INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/1232E 2 TABLE I. Testing and inspection. Method Limits Inspection MIL-STD-1311 Notes Test Conditions Symbol Min Max Unit Preproduction sample approval inspection Humid
6、ity 1011 - - - - - - Degradation due to vibration 4021 - - t = 1 hour - - - - Mechanical insertion - 1/ 3/ - - - - - Conformance inspection, part 1 Ignitor voltage drop 4406 - - - Ii = 100 A dc Eid 275 475 V dc Spike-leakage energy 4452 - 1 Ws - 0.25 erg Flat-leakage power 4452 - 1 pf - 75 mw Temper
7、ature cycling (nonoperating) 1027 - - - - - - Ignitor ignition time 4401 - - Ebb = -750 V dc; Ri = 4.5 Meg t - 5.0 sec Low-level VSWR 4473 4/ - F = (F1, F2, F3, F4, and F5) 0.1% - 1.3 - Arc loss 4488 - 1 La - 0.3 dB Conformance inspection, part 2 Dielectric material strain 4101 - - - - - - Insertion
8、 loss 4416 - - F = F3 5% Li - 0.5 dB Ignitor interaction 4421 - - Ii = 100 A dc Li - 0.2 dB Ignitor noise ratio 4460 - - Fo = 1,300 MHz; Ii = 100 A dc Nr - 1.3 - Recovery time 4471 - 2 t - 20 s See footnotes at end of table. Provided by IHSNot for ResaleNo reproduction or networking permitted withou
9、t license from IHS-,-,-MIL-PRF-1/1232E 3 TABLE I. Testing and inspection - Continued. Method Limits Inspection MIL-STD-1311 Notes Test Conditions Symbol Min Max Unit Conformance inspection, part 3 Life test - 5/ 6/ 2 Group D; F = F3 3%; R = 2.5 Meg t 1,000 - hours Life-test end points: Spike-leakage
10、 energy Ignitor noise ratio Recovery time Ignitor voltage drop Insertion loss Arc loss Temperature cycling life test - 4452 4460 4471 4406 4416 4488 1027 - - - - - - - 1 - 2 - - 1 - Ii = 100 A dc Ii = 100 A dc 10 cycles Ws Nr t Eid Li La - - - - - - - - 0.50 1.5 25 550 0.7 0.3 - erg - s V dc dB dB -
11、 1/ A suitable gasket shall be bolted between the tube and the mounting seat. Tubes shall be supplied with gaskets at both ends. 2/ Preproduction sample approval requirements hereby replace any qualification requirements referable to the product covered herein. The term “First article testing“ shall
12、 be considered as synonymous with the term “Preproduction sample approval testing.“ All tests applicable herein (including all preproduction sample approval and conformance inspection, parts 1, 2, and 3) shall be performed during preproduction sample inspection. A failure of any one tube in any of t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILPRF11232E2012ELECTRONTUBEGASSWITCHINGTYPE7166PDF

链接地址:http://www.mydoc123.com/p-691940.html