1、NOT MEASUREMENT SENSITIVE MIL-HDBK-1131B 29 October 2008 SUPERSEDING MIL-HDBK-1131A 14 June 2004 DEPARTMENT OF DEFENSE HANDBOOK FOR STORAGE SHELF LIFE AND REFORMING PROCEDURES FOR ALUMINUM ELECTROLYTIC FIXED CAPACITORS THIS DOCUMENT IS FOR GUIDANCE ONLY. DO NOT CITE THIS DOCUMENT AS A REQUIREMENT. A
2、MSC N/A FSC 5910 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-HDBK-1131B FOREWORD 1. This handbook is approved for use by all Departments and Agencies of the Department of Defense. 2. This document provides guidance for Storage Shelf Life and
3、Reforming Procedures for Aluminum Electrolytic Fixed Capacitors. 3. This Military Handbook is for guidance only. This handbook cannot be cited as a requirement. If it is, the contractor does not have to comply. 4. Comments, suggestions, or questions on this document should be addressed to: Defense S
4、upply Center, Columbus, DSCC-VAT, Post Office Box 3990, Columbus, OH 43218-3990 or e-mailed to capacitorfilterdscc.dla.mil. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at http:/assist.daps.dla.mil Provided by
5、IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-HDBK-1131B iii PARAGRAPH PAGE FOREWORD - ii 1. SCOPE 1.1 Scope - 1 1.2 Purpose - 1 2. APPLICABLE DOCUMENTS - 1 2.1 General - 1 2.2 Government documents- 1 2.3 Order of precedence - 1 3. DEFINITIONS - 1 4. GENER
6、AL REQUIREMENTS - 2 4.1 Type of storage - 2 4.2 Storage and issue acceptability - 2 4.3 Inspection frequency - - 2 4.4 Inspection sampling - 2 4.5 Disposal period - - 3 4.6 Inspection method - 3 4.7 Defects list - 3 5. DETAILED REQUIREMENTS - 4 5.1 DC leakage limits - 4 5.3.1 Capacitor reforming gro
7、ups- 4 5.4 Packaging - 4 6. NOTES - - 5 6.1 Surge voltage - 5 6.2 Line voltage variations - 6 FIGURES Figure 1 Schematic diagram - 5 Figure 2 Surge voltage - 5TABLES Table I Sampling plan - 3 Table II Rated voltage, surge voltage, and percent surge allowed - 6 CONCLUDING MATERIAL - 7 Provided by IHS
8、Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-HDBK-1131B 1 1. SCOPE 1.1 Scope. This handbook provides guidance in determining and prolonging the serviceability of aluminum electrolytic fixed capacitors during storage. This handbook is for guidance only. This
9、handbook cannot be cited as a requirement. If it is, the contractor does not have to comply. 1.2 Purpose. The purpose of this document is to furnish guidance for the inspection, storage, reformation and issue of aluminum electrolytic fixed capacitors, Federal Supply Class (FSC) 5910. 2. APPLICABLE D
10、OCUMENTS 2.1 General. The documents listed below are not necessarily all of the documents referenced herein, but are the ones that are needed in order to fully understand the information provided by this handbook. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The followin
11、g specifications, standards, and handbooks form a part of this document to the extent specified herein. SPECIFICATIONS MILITARY MIL-C-62 - Capacitors, Fixed, Electrolytic (DC Aluminum, Dry Electrolyte, Polarized) General Specification For. MIL-PRF-39018 - Capacitors, Fixed, Electrolytic (Aluminum Ox
12、ide), Established Reliability and Non-Established Reliability, General Specification For. (Copies of these documents are available online at http:/assist.daps.dla.mil/quicksearch/ or http:/assist.daps.dla.mil or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelp
13、hia, PA 19111-5094.) 2.3 Order of precedence. In the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been o
14、btained. 3. DEFINITIONS This section is not applicable. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-HDBK-1131B 2 4. GENERAL REQUIREMENTS 4.1 Type of storage. Aluminum electrolytic fixed capacitors should be stored in warehouse space under one
15、 of the following conditions: a. Condition A: (1) MIL-C-62 and non-military grade: Temperature +35C or less, 60 15 percent relative humidity, and air pressure of 725 75 millimeters of mercury. (2) MIL-PRF-39018: Temperature +40C or less, 50 20 percent relative humidity, and air pressure of 725 75 mi
16、llimeters of mercury. b. Condition B: Temperature, relative humidity, or air pressure other than that specified above within specified storage limits. 4.2 Storage and issue acceptability. 4.2.1 MIL-C-62 and non-military grade aluminum electrolytic fixed capacitors should be acceptable for storage an
17、d issue within a 6-year certified period computed from date of manufacture if stored as recommended in 4.1, condition A (1), or within a 4-year period computed from date of manufacture if stored as recommended in 4.1, condition B, or within 3 years from date of last inspection (see 4.3). 4.2.2 MIL-P
18、RF-39018 aluminum electrolytic fixed capacitors should be acceptable for storage and issue within a 10-year certified period computed from date of manufacture if stored as recommended in 4.1, condition A (2), or within 4 years from date of last inspection (see 4.3). 4.3 Inspection frequency. 4.3.1 M
19、IL-C-62 and non-military grade: At the end of 6 years, or 4 years from the date of manufacture, depending upon storage conditions (see 4.2) or 3 years from the last inspection period, capacitors should be inspected (see 4.6) to determine if the dc leakage requirements of the applicable acquisition d
20、ocument can be met. 4.3.2 MIL-PRF-39018: At the end of 10 years or 5 years from the date of manufacture, depending upon storage conditions (see 4.2) or 5 years from the last inspection period, capacitors should be inspected (see 4.6) to determine if the dc leakage requirements of the applicable acqu
21、isition document can be met. 4.4 Inspection sampling. At the end of the specified period (see 4.3), it is recommended that a sample as shown in table I be selected. If the number of defectives exceeds zero, it is recommended that all capacitors be tested; those units not meeting the requirements of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILHDBK1131B2008STORAGESHELFLIFEANDREFORMINGPROCEDURESFORALUMINUMELECTROLYTICFIXEDCAPACITORSPDF

链接地址:http://www.mydoc123.com/p-691390.html