DLA MIL-DTL-8777 F-2011 WIRE ELECTRICAL SILICONE-INSULATED COPPER 600-VOLT 200篊.pdf
《DLA MIL-DTL-8777 F-2011 WIRE ELECTRICAL SILICONE-INSULATED COPPER 600-VOLT 200篊.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-DTL-8777 F-2011 WIRE ELECTRICAL SILICONE-INSULATED COPPER 600-VOLT 200篊.pdf(30页珍藏版)》请在麦多课文档分享上搜索。
1、 AMSC N/A FSC 6145 MIL-DTL-8777F 9 November 2011 SUPERSEDING MIL-DTL-8777E 21 May 2007 DETAIL SPECIFICATION WIRE, ELECTRICAL, SILICONE-INSULATED, COPPER, 600-VOLT, 200C This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This speci
2、fication covers single conductor wire with a silicone primary insulation capable of continuous operation at 600 volts and a maximum conductor temperature of 200C (392F). These wires are suitable for use in aircraft and missiles using any combination of electrical loading and ambient temperature, pro
3、vided the maximum conductor temperature is not exceeded. The wires covered by this specification are not intended as fire-resistant wires. 1.2 Classification. Single conductor insulated wire as specified in the applicable MS sheet (see 6.2). 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed
4、in this section are specified in sections 3, 4, or 5 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, docume
5、nt users are cautioned that they must meet all specified requirements of documents cited in sections 3, 4, or 5 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, and standards and handbooks. The following specifications, standards and handbooks fo
6、rm a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. INCH-POUND Comments, suggestions, or questions on this document should be addressed to DLA Land and Maritime, ATTN: VAI, P.O. Box 3990
7、, Columbus, OH 43218-3990, or email to WireCabledla.mil. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at https:/assist.daps.dla.mil. Inactive for new design after 01 June 1998. Provided by IHSNot for ResaleNo r
8、eproduction or networking permitted without license from IHS-,-,-MIL-DTL-8777F 2 COMMERCIAL ITEM DESCRIPTION A-A-59551 - Wire, Electrical, Copper. FEDERAL SPECIFICATION TT-I-735 - Isopropyl Alcohol. FEDERAL STANDARD FED-STD-228 - Cable and Wire, Insulated; Methods of Testing. DEPARTMENT OF DEFENSE S
9、PECIFICATIONS MIL-W-5088 - Wiring, Aerospace Vehicle. MIL-PRF-5606 - Hydraulic Fluid, Petroleum Base, Aircraft, Missile, and Ordnance. MIL-DTL-5624 - Turbine Fuel, Aviation Grades JP-4, JP-5, and JP-5/JP-8 ST. MIL-PRF-7808 - Lubricating Oil, Aircraft Turbine Engine, Synthetic Base. DEPARTMENT OF DEF
10、ENSE STANDARDS MIL-STD-104 - Limits for Electrical Insulation Color. MS25471 - Wire, Electrical Silicone-Insulated, Copper, 600 Volt, 200C, Polyester Jacket. MS27110 - Wire, Electrical Silicone-Insulated, Copper, 600 Volt, 200C, FEP Jacket. (Copies of these documents are available online at https:/a
11、ssist.daps.dla.mil/quicksearch/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.3 Non-Government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the docume
12、nts are the issues of the documents cited in the solicitation or contract (see 6.2). ASTM INTERNATIONAL ASTM B298 - Wire, Copper, Silver-Coated Soft or Annealed. (Copies of these documents are available online at http:/www.astm.org or from the ASTM International, P.O. Box C700, 100 Barr Harbor Drive
13、, West Conshohocken, PA 19428-2959.) X-RITE, INCORPORATED Munsell Book of Color (Copies of this document are available online at www.x- or requested from X-rite Corporate Headquarters, USA, 4300 44thStreet, SE, Grand Rapids, MI 49512.) Provided by IHSNot for ResaleNo reproduction or networking permi
14、tted without license from IHS-,-,-MIL-DTL-8777F 3 NCSL INTERNATIONAL NCSL-Z540.1 Calibration Laboratories and Measuring and Test Equipment, General Requirements (Copies of these documents are available online at http:/www.ncsli.org or from NCSL International 2995 Wilderness Place, Suite 107 Boulder,
15、 Colorado 80301-5404.) SAE INTERNATIONAL SAE AS1241 - Fire Resistant Phosphate Ester Hydraulic Fluid for Aircraft (Copies of these documents are available online at http:/www.sae.org or from the SAE World Headquarters, 400 Commonwealth Drive, Warrendale, PA 15096-0001.) 2.4 Order of precedence. In e
16、vent of a conflict between the text of this document and the references cited herein (except for related specification sheets), the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3.
17、REQUIREMENTS 3.1 Specification sheets. The individual item requirements shall be as specified herein and as specifed in the applicable specification sheet. In the event of any conflict between the requirements of this specification and the specification sheet, the latter shall govern. 3.2 Qualificat
18、ion. Wires furnished under this specification shall be products that are authorized by the qualifying activity for listing on the applicable qualified products list (QPL) before contract award (see 4.6 and 6.3). 3.3 Materials. The materials for the principal components of the wire shall be as specif
19、ied herein. Prior approval to use substitute material must be obtained from the qualifying activity. When a definite material is not specified, a material shall be used that will enable the finished products to meet the performance requirements of this specification. Acceptance or approval of any co
20、nstituent material shall not be construed as a guaranty of the acceptance of the finished product. All materials used in the manufacture of wires furnished hereunder shall be of such quality and form that the finished product conforms to the requirements of this specification. All materials used sha
21、ll conform to the requirements specified herein. 3.3.1 Recycled, recovered, or environmentally preferable materials. Recycled, recovered, or environmentally preferable materials should be used to the maximum extent possible, provided that the material meets or exceeds the operational and maintenance
22、 requirements, and promotes economically advantageous life-cycle costs. 3.3.2 Conductor material. Strands used in the manufacture of conductors shall be annealed or soft drawn copper wire from the best obtainable, commercially pure wire bars, and as specified in A-A-59551. Provided by IHSNot for Res
23、aleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-8777F 4 3.3.3 Insulating materials. 3.3.3.1 Primary insulation. The primary insulation shall be of silicone rubber, applied by extrusion or taping. If a silicone rubber tape is used, it shall be fused into a homogeneous
24、mass. 3.3.3.2 Inner braid. The inner braid shall consist of glass fibers or a combination of glass fibers and polyester fibers covering the primary insulation. The inner braid shall be treated with a heat-resistant finisher. 3.3.3.3 Outer jacket. The outer jacket shall be as specified in the applica
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILDTL8777F2011WIREELECTRICALSILICONEINSULATEDCOPPER600VOLT200 PDF

链接地址:http://www.mydoc123.com/p-691271.html